• 제목/요약/키워드: Fabry-Perot laser

검색결과 106건 처리시간 0.039초

Tunable Photonic Microwave Delay Line Filter Based on Fabry-Perot Laser Diode

  • Heo, Sang-Hu;Kim, Junsu;Lee, Chung Ghiu;Park, Chang-Soo
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.27-33
    • /
    • 2018
  • We report the physical implementation of a tunable photonic microwave delay line filter based on injection locking of a single Fabry-Perot laser diode (FP-LD) to a reflective semiconductor optical amplifier (RSOA). The laser generates equally spaced multiple wavelengths and a single tapped-delay line can be obtained with a dispersive single mode fiber. The filter frequency response depends on the wavelength spacing and can be tuned by the temperature of the FP-LD varying lasing wavelength. For amplitude control of the wavelengths, we use gain saturation of the RSOA and the offset between the peak wavelengths of the FP-LD and the RSOA to decrease the amplitude difference in the wavelengths. From the temperature change of total $15^{\circ}C$, the filter, consisting of four flat wavelengths and two wavelengths with slightly lower amplitudes on both sides, has shown tunability of about 390 MHz.

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

파장측정 장치의 제작 및 반도체레이저의 광 스펙트럼분석에 관한 연구 (A study on the Fabrication of Wavelength Measurement System and the Spectrum Anslysis of Laser Diodes)

  • 오수환;이석정;박윤호;홍창희
    • 한국광학회지
    • /
    • 제6권4호
    • /
    • pp.359-364
    • /
    • 1995
  • 본 연구에서는 분광기와 컴퓨터 인터페이싱에 의해 파장측정장치를 제작하였으며 제작된 파장측정 장치를 이용하여 반도체레이저인 Fabry-Perot LD와 DFB-LD의 파장특성을 측정하고 그 결과를 분석함으로써 본 연구실에서 제작한 파장측정 장치가 반도체 레이저의 발진 파장특성을 분석하는데 실용적으로 이용될 수 있음을 알 수 있었다.

  • PDF

분광 영역 모드록킹 레이저를 이용한 공진형 광섬유 격자 센서 (Resonance Fiber Bragg Grating Sensor system based on Fourier Domain Mode-locking Laser)

  • 최병권;전민용
    • 한국광학회지
    • /
    • 제23권5호
    • /
    • pp.211-216
    • /
    • 2012
  • 본 논문은 분광 영역 모드록킹(Fourier domain mode-locking: FDML) 레이저를 기반으로 공진형 광섬유 격자 센서를 구현한 결과를 보고한다. FDML 레이저는 파브리-페롯 가변 필터를 이용하여 링 형태로 구성하며, 레이저 공진기 안에 광섬유 격자 2개를 한 쌍으로 하여 센서부 2개를 삽입한 구조이다. 광섬유 격자는 반사 거울 역할을 하며, 광섬유 격자의 위치에 따라 독립된 FDML 레이저 공진기를 구성한다. 각각 센서부의 공진 주파수는 46.687 kHz 와 44.340 kHz이다. FBG 센서 시스템에 정적 및 동적 스트레인을 가하였으며, 정적 스트레인에 대해 파장 영역과 시간 영역에서 측정된 스트레인에 대한 변화율은 각각 $0.61pm/{\mu}{\epsilon}$, $0.8ns/{\mu}{\epsilon}$ 이다.

Wavelength Swept 모드 록킹된 광섬유 레이저를 이용한 광주파수 영역에서 반사계 (Optical frequency domain reflectometry based on Wavelength swept mode locked fiber laser)

  • 오명숙;박희수;김병윤
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.204-205
    • /
    • 2003
  • We demonstrate a novel OFDR system with compactness and short measurement time based on the use of a wavelength-swept mode-locked fiber laser. The optical source uses an intra-cavity tunable Fabry-Perot filter as a tuning element. The fiber laser sweeps 20 nm in less than 10 ms. Spatial resolution of 100 fm and total measurement range of several centimeters are demonstrate

  • PDF

광가입자용 $1.3\mu{m}$ SSC-FP-LD의 모드변환기 구조 설계 (Spot-size converter design of an $1.3\mu{m}$ SSC-FP-LD for optical subscriber network)

  • 심종인;진재현;어영선
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.411-417
    • /
    • 2000
  • SSC(Spot-size converter)가 집적된 1$1.3\mu{m}$ FP(Fabry-Perot)-LD(Laser Diode)에서 SSC 영역의 광도파로 구조가 단일모드광섬유와의 광결합 효율 및 정렬오차에 미치는 영향에 대해서 3차원 BPM(Beam Propagation Method)를 사용하여 알아보았다. 수지 taper의 경우 광결합효율을 향상하기 위해서는 taper 끝단에 충분한 길이의 직선도파로를 형성하는 것이 중요함을 알수 있었다. 또한 수평 taper 구조에서는 출사단 방향으로 도파로폭이 좁아지는 경우가 넓어지는 경우에 비해 유리하고, 수직 taper에 비해 완만한 도파로 경사가 필요함을 알 수있었다. 단일모드 광섬유와의 광결합 손실 및 정렬오차 허용도의 관점에서 좋은 특성을 주는 SSC 도파로 모양을 제시하였다.

  • PDF

반사 스펙트럼을 이용한 VCSEL 에피층의 두께 오차 평가 (Estimating the Thickness Errors in Vertical-Cavity Surface-Emitting Laser Structures from Optical Reflection spectra)

  • 김남길;김상배
    • 대한전자공학회논문지SD
    • /
    • 제40권8호
    • /
    • pp.572-579
    • /
    • 2003
  • vertical-cavity surface-emitting laser(VCSEL) 웨이퍼에서 측정한 반사 스펙트럼을 전달 매트릭스 방법으로 계산한 반사스펙트럼과 비교함으로써 비파괴적인 방법으로 구조적인 두께 오차가 발생한 층을 찾아 내고 오차의 크기를 추정하는 방법론을 제시하였다. DBR 층의 오차를 종합하여 나타낸 n-DBR 층의 두께 오차, 즉 유효 오차를 도입하면, 반사 스펙트럼의 모양은 유효 오차에만 의존한다는 사실에 이 방법의 근거를 두고 있다. 활성층 영역의 두께 오차는 Fabry-Perot 발진파장에만 영향을 주며, 랜덤 두께 오차의 표준 편차 값이 0.005 이하일 때에 측정과 계산된 반사 스펙트럼의 비교는 신뢰성을 갖는다. 이 방법론은 VCSEL 웨이퍼 제작시 측정되는 반사 스펙트럼을 이용하므로 비파괴적이며, 0.5 nm의 두께 오차를 찾아 낼 수 있을 정도로 정밀도가 높다.

TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선 (RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module)

  • 이동수
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.8-12
    • /
    • 2003
  • TO-can 레이저 다이오드를 사용한 광송수신기 모듈의 주파수 대역의 특성을 관찰하였다. 레이저 다이오드의 등가회로를 추출하기 위한 R-L-C변수는 임피던스 분석기를 이용하였다. 칩콘덴서를 사용하여 패키지내의 도선에 의한 인덕턴스 성분과의 임피던스 정합을 시도하였으나 저주파수 대역에서 공진으로 인한 경사가 발견되었다. 표면실장 형으로 소자를 구성하여 사용함으로써 공진주파수를 이동시켜 원하는 주파수 대역에서 공진 경사를 제거할 수 있었다.

Terahertz transmission through femtosecond-machined metal structures

  • Lee, J.U.;Seo, M.;Kim, D.S.;Jeoung, S.C.;Park, Q-Han
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.102-103
    • /
    • 2005
  • Using THz time-domain spectroscopy, we study plasmonic band gaps in periodic metal arrays of slits. Femtosecnd machining system guarantees good quality sub millimeter structures for THz spectroscopy. Fabry-Perot effect enhances the transmission when the two resonances cross but does not alter the surface plasmon peak positions.

  • PDF