• 제목/요약/키워드: Fabry Perot interferometer

검색결과 103건 처리시간 0.021초

광섬유 센서를 이용한 구조물의 열변형 및 온도 측정 (Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

복합재료의 변형 및 파손탐지를 위한 광섬유 TR-EFPI 센서의 적용 (Application of a fiber optic TR-EEPI sensor to detect deformation and failure in composite materials)

  • 박래영;권일범;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • A study on the method that can measure the internal strain of composite materials is performed to monitor the health status of composite structures. A fiber optic sensor was constructed using the total reflected extrinsic Fabry-Perot interferometer(TR-EFPI) probe with a broadband light source. Result obtained from electrical strain gage adhered on the aluminum beam specimen was compared with that from the fiber optic TR-EFPI sensor and showed a good agreement. It was found that fiber optic TR-EFPI sensor system was adequate for monitoring the strain and thus failure processes in the interior of composite materials.

  • PDF

신경망 제어기를 이용한 광섬유가 부착된 복합재 보의 진동제어 (Neuro-Adaptive Vibration Control of a Composite Beam with Optical Fiber Sensor)

  • 김도형;양승만;한재흥;김대현;이인;김천곤;홍창선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.135-138
    • /
    • 2002
  • Experimental studies on vibration control of a composite beam with a piezoelectric actuator and an extrinsic Fabry-Perot interferometer (EFPI) have been performed using a neural network controller and an LQG controller. Vibration control performance was investigated in the nonlinear sensing range according to the vibration amplitudes. Using a neuro-controller, adaptive vibration control experiment has been performed for the structure with frequency variations, and its performance is compared with that of an LQG controller. The vibration control results show that the neuro-controller has good performance and robustness with respect to the system parameter variations.

  • PDF

광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지 (Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

광섬유 TR-EFPI 센서를 이용한 GFRP 직교 적층판의 변형률 해석 (Strain Analysis in GFRP Cross-Ply Laminates Using TR-EFPI Optical Fiber Sensor)

  • 우성충;최낙삼;권일범
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.150-153
    • /
    • 2003
  • Longitudinal strains({$varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been studied using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI). Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. Both TR-EFPI sensor and strain gauge bonded on the specimen surface showed excellent agreement within -0.0086 ~ +0.0302% strain. It was shown that values of {$varepsilon}_x$ in the interior of the surface layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results were ascertained with finite element analysis. Embedded TR-EFPI optical fiber sensor could measure accurately the internal strains which were different from the surface.

  • PDF

섬유-금속 적층판의 인장 및 압입 하중에서의 손상감지 (Damage Detection of Fiber-Metal Laminates Under Axial and Indentation Load)

  • 양유창;한경섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.370-375
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile and indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

광섬유 센서를 이용한 평판의 진동 감지 및 제어 (Vibration Sensing and Control of a Plate Using Optical Fiber Sensor)

  • 김도형;한재흥;양승만;김대현;이인;김천곤;홍창선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.459-464
    • /
    • 2001
  • Vibration control of a plate using an optical fiber sensor and a PZT actuator is considered in this study. An aluminum plate with attached Extrinsic Fabry-Perot Interferometer (EFPI) and PZT actuator is prepared for experimental investigation. Vibration level of EFPI that can represent the mechanical strain without severe distortion is validated by forced vibration experiment. A numerical model of the plate is constructed based on the experimentally obtained frequency responses, and an optimal controller is designed for the multi-modal vibration suppression. It is found that the vibration level of the first three modes can be greatly reduced. The effect of low-pass filtering used to eliminate high frequency noise on the stability and control performance is also considered.

  • PDF

섬유-금속 적층판의 압입 하중에서의 손상 및 파손 검출 (Damage and Failure Detection of Fiber-Metal Laminates Under Indentation Load)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.42-45
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

Sound Propagation in 5CB Liquid Crystals Homogeneously Confined in a Planar Cell

  • Ko, Jae-Hyeon;Hwang, Yoon-Hwae;Kim, Jong-Hyun
    • Journal of Information Display
    • /
    • 제10권2호
    • /
    • pp.72-75
    • /
    • 2009
  • The Brillouin spectrum of 4'-n-pentyl-4-cyano-biphenyl (5CB) liquid crystals homogeneously confined in a planar liquid crystal (LC) cell was measured using a 6-pass tandem Fabry-Perot interferometer. By adopting a special right-angle scattering geometry, the sound velocity of 5CB was estimated from the Brillouin shift without knowing the refractive index. The sound velocity of the longitudinal wave propagating along the direction of the directors aligned parallel to the glass plates of the LC cell was 1784${\pm}$7 m/s at 300 K. The attenuation coefficient $\alpha$ was estimated to be approximately $1.9{\times}10^6m^{-1}$, which is about twice as large as that of the longitudinal sound wave propagating along the direction perpendicular to the directors. The present method may be very useful in the evaluation of the elastic properties of the materials used in display devices, whose refractive indices are not known.

광섬유센서를 이용한 복합적층판의 변형률 해석 (Strain Analysis of Composite Laminates Using Optical Fiber Sensor)

  • 우성충;최낙삼;박래영;권일범
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.111-114
    • /
    • 2004
  • Using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI), longitudinal strains(Ex) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been measured. Transmission optical microscopy was employed to study the damage formation around the TR-EFPI sensor. It was observed that values of ex in the interior of the skin layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results agreed well with those from finite element analysis on the basis of uniform stress model. Large strains in the core layer led to the occurrence of transverse cracks which drastically reduced the strain at failure of optical fiber sensor embedded in the core layer.

  • PDF