• 제목/요약/키워드: Fabry Perot interferometer

검색결과 103건 처리시간 0.028초

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

Fabry-Perot형 광섬유 배열센서의 방전 음압 계측 (Sound Measurements of the Discharge Break Down Using Fabry-Perot Sensor Array)

  • 이종길;이준호;이진우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.770-773
    • /
    • 2003
  • To measure discharge breakdown acoustic signal, Fabry-Perot interferometer fiber optic sensor is used. Fiber optic sensor array can measure the partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Fabry-Perot interferometer is selected as an fiber optic sensor array. It is shown that Fabry-Perot fiber optic sensor array detected discharge breakdown acoustic signal, effectively.

  • PDF

레이저 유도 초음파를 이용한 재료평가 및 비파괴 검사 시스템 개발에 관한 연구 (The Study on the Material Evaluation and Development of Nondestructive Inspection System Using Laser Guided Ultrasonics)

  • 김재열;송경석;김창현;김유홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2004
  • In the present study, a Nd;YAG Laser (pulse type) was used to emit ultrasonic signals to a test material. In addition, a total ultrasonic investigation system was designed by adopting a Fabry-Perot interferometer, which receives ultrasonic signals without any contact. For non-destructive test SM45C, which contains some flaws was used as a test material. Because it is easy to align light beam in receiver, and the length of the light beam does not change much even if convex mirror leans towards one side, confocal Fabry-Perot interferometer, which has stable frequency, and PI control are used to correct interfered and unstable signals from temperature, fluctuation and time shift of laser frequency. Stable signals are always obtained by the feedback of PI circuit signals in the confocal Fabry-Perot interferometer. The type, size and position of flaws inside the test material were examined by achieving the stabilization of an interferometer. This study presented a useful method, which could quantitatively investigate the fault of objects by using a Fabry-Perot interferometer.

  • PDF

소형 퓨즈에 흐르는 전류 측정용 광섬유 패브리-페로 간섭형 센서 (Fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse)

  • 박성순;박재희;김경찬
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.91-95
    • /
    • 2005
  • A fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse have been studied. The proposed current sensor was fabricated with a fiber Fabry-Perot interferometer attached close to a fuse line inside a small fuse. The fiber Fabry-Perot interferometer used in the experiment had the 10 mm cavity length and the 3.5 % reflectance mirrors. The phase shift of the output signal of the current sensor was proportional to the square of current applied to the fuse and the sensitivity of the current sensor was 0.87 degree/$mA^{2}$. The experiment results show that this sensor can be used for measuring current flowing into the fuse.

실리콘 비선형 Fabry-Perot 간섭계를 이용한 광펄스 변조와 축약 (Pulse Compression by the Nonlinear Silicon Fabry-Perot Interferometer)

  • 김달현;이재형;장준성
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.40-45
    • /
    • 1990
  • 반도체 실리콘은 띠간격 근처의 에너지를 갖는 광자를 흡수하여 생성된 전자-정공쌍에 의해 굴절률이 비선형적으로 변하며 이에 따라 입사한 광펄스를 변조시킨다. Finesse가 큰 실리콘 Fabry-Perot 간섭계를 형성할 때, 이를 투과하는 광펄스가 실리콘의 굴절률을 변화시켜 스스로 간섭계의 보강간섭조건을 만족시킴으로써 반치폭이 1/5까지 축약되는 현상을 관측하였다. 그리고 관측된 결과는 수치해석으로 구한 결과와 잘 일치하였다.

  • PDF

Fabry-Perot을 이용한 두 개의 광섬유 센서배열의 횡방향 음압 감지 특성 (Lateral direction acoustic detection of fiber optic sensor array using Fabry-Perot)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.342-345
    • /
    • 2005
  • To detect external acoustic signal, fiber optic sensor array using Fabry-Perot interferometer which had benefit of minimize and light-weight was used. The sensor head has 1cm in length, total length of fiber is 9.5cm, and the sensor supported at both ends, simply. External sound applied in lateral direction and detected two signals were compared each other. It was confirmed that the Fabry-Perot interferometric sensor array detected acoustic signal, effectively.

  • PDF

광섬유 Fabry-Perot 간섭계를 이용한 초음파의 검출 (Detection of Ultrasonics by Optical Fiber Fabry-Perot Interferometer)

  • 지성훈;박동빈;김달우
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.298-299
    • /
    • 2003
  • 초음파는 일반적으로 물질의 내부결함을 측정하거나 결정입경과 같은 물질의 특성을 측정하는데 사용된다. 현재 초음파를 검지하는 방법으로는 탐촉자를 물질에 접촉시켜서 초음파를 측정하는 접촉식 방법이 널리 사용되고 있다. 따라서, 이러한 접촉식 초음파 검출방법은 원격탐사를 하는데에 어려움이 있다. 이런 문제점을 보완하기 위하여 본 연구에서는 패브리-페로 간섭계(Fabry-Perot interferometer)를 이용하여 비접촉식으로 초음파를 검출하는 방법에 대하여 실험하였다. (중략)

  • PDF

양단이 지지된 Fabry-Perot 광섬유센서의 음압 감지 특성 연구 (Sound Detection Characteristics Using Fabry-Perot Fiber Optic Sensor which Simply Supported in Structure)

  • 이종길;이진우;이준호
    • 한국음향학회지
    • /
    • 제22권7호
    • /
    • pp.585-591
    • /
    • 2003
  • 본 연구에서는 소형화 및 경량화의 특성을 가진 Fabry-Perot형 간섭계를 구성하였다. 음향이 광섬유의 횡방향으로 감지되도록 센서 헤드부를 1㎝정도로 제작하고 총 길이가 9.5㎝인 광섬유의 양단을 단순 지지토록 하였다. 센서의 음향 감지특성을 관찰하기 위하여 무지향성 스피커를 이용하여 음향신호를 인가하였다 횡방향으로 입력된 음향 신호를 광섬유 센서와 마이크로폰이 감지한 신호를 비교하였다. 1㎑ 이하의 신호에서는 광섬유 센서가 마이크로폰보다 감지 특성이 좋으나 2 ㎑에서는 광섬유센서의 감지 특성이 감소하였다. 이것은 제작된 광섬유 센서의 지지구조의 특성을 나타낸 것이며 실험을 통하여 Fabry-Perot 간섭계용 센서는 횡방향의 음향을 잘 감지함을 확인하였다. 이러한 형태의 센서는 지능구조물의 건강진단 모니터링 분야에도 적용가능 하리라 판단된다.

Development of High-Sensitivity Cantilever-Detected ESR Measurement Using a Fiber-Optic Interferometer

  • Tokuda, Yuki;Tsubokura, Daichi;Ohmichi, Eiji;Ohta, Hitoshi
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.173-177
    • /
    • 2013
  • Cantilever-detected high-frequency electron spin resonance (ESR) is a powerful method of sub-terahertz and terahertz ESR spectroscopy for a tiny magnetic sample at low temperature. In this technique, a small magnetization change associated with ESR transition is detected as deflection of a sample-mounted cantilever. So far, we have succeeded in ESR detection at 370 GHz using a commercial piezoresistive microcantilever. The spin sensitivity was estimated to ${\sim}10^{12}$ spins/gauss. In order to further increase the sensitivity, we adopt a fiber-optic-based detection system using a Fabry-Perot interferometer in place of piezoresistive system. Fabry-Perot cavity is formed between an optical-fiber end and microcantilever surface, and a change in the interference signal, corresponding to the cantilever deflection, is sensitively detected. This system is suitable for low-temperature and high-magnetic-field experiments because of its compact setup and less heat dissipation. In this study, performance of Fabry-Perot interferometer is evaluated, and its application to cantilever-detected ESR measurement is described.

Dual Fabry-Perot Interferometer to Improve the Color Purity of Displays

  • Keun Soo Shin;Jun Yong Kim;Yun Seon Do
    • Current Optics and Photonics
    • /
    • 제7권2호
    • /
    • pp.191-199
    • /
    • 2023
  • We propose a dual Fabry-Perot interferometer (DFPI) structure that combines two Fabry-Perot interferometers. The structure is designed to have spectral peaks in the red, green, and blue regions simultaneously, to be applicable to R, G, and B subpixels without any patterning process. The optimized structure has been fabricated on a glass substrate using a thermal evaporation technique. When the DFPI structure was attached to the quantum-dot color-conversion layer, the full width at half maximum values of the green and red spectra decreased by 47.29% and 51.07% respectively. According to CIE 1931 color space, the DFPI showed a 37.66% wider color gamut than the standard RGB color coordinate. Thus it was experimentally proven that the proposed DFPI structure improved color purity. This DFPI structure will be useful in realizing a display with high color purity.