• Title/Summary/Keyword: Fabrication of denture

Search Result 109, Processing Time 0.019 seconds

The cognition of denture fabrication activities and the costs in National Health Insurance for elderly denture (노인틀니 국민건강보험의 틀니제작행위 및 비용에 관한 인식)

  • Yu, Chin-Ho;Nam, Sang-Yong;Kim, Ji-Hwan;Nam, Kwan-Woo;Lee, Sun-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the cognition of denture fabrication activities and its cost in National Health Insurance for elderly denture. Methods: A self-administered questionnaire was completed by 41 dental laboratories' owner who was research subjects of HIRA(Health Insurance Review & Assessment Service)'s policy research for elderly denture in 2011. The questionnaire consisted of general characteristics of the subjects, dental technicians' knowledge of national health insurance coverage of elderly denture, job-related changes after national health insurance coverage of elderly denture including validity of denture fabrication activity classification and the cost for each service. Each question was measured by Likert 5 point scale or frequency. The collected data were analyzed by SPSS 16.0. Results: Most of the research subjects had been fabricating national health insurance coverage denture(92.7%), also had ample knowledge of national health insurance coverage denture for elderly. Job-related changes after national health insurance coverage of elderly denture revealed marginal differences in the quality. The validity of fabrication activity classification of resin based complete denture was $3.71{\pm}1.023$ by Likert 5 point scale. Conclusion: The goal of national health insurance for elderly denture is to promote elderly's health and well-being. To fabricate denture is a very important part of the denture treatment. For this reason, denture fabrication activity classification and the cost analysis plan should be duly reflected in the policy of national health insurance for elderly denture.

Modified soft tissue cast for fixed partial denture: a technique

  • Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.33-36
    • /
    • 2011
  • In process of fabrication of a fixed partial denture, dies are trimmed to expose margins of the preparations. The need for the soft tissue cast is quite evident as the soft tissue emergence profile that surrounds the prepared tooth is destroyed in the process of fabrication. This article describes a modified technique to fabricate the soft tissue cast for the conventional fixed partial denture. The impression made with the polyvinylsiloxane was first poured to prepare the die cast. After retrieval of the cast, the same impression was poured second time with the resin based resilient material to cover the facial and proximal gingival areas. The remaining portion of the impression was poured with the gypsum material. This technique does not require additional clinical appointment, second impression procedure, technique sensitive manipulations with impression, or cumbersome laboratory procedures. The simplicity of this technique facilitates and justifies its routine use in fabrication of the fixed partial denture.

Complete denture fabrication of edentulous patient with severe alveolar bone resorption using suction mechanism: A case report (치조제 흡수가 심한 무치악 환자에서 흡착원리를 이용한 총의치 수복 증례)

  • Kim, Hyun-Ah;Yun, Kwi-Dug;Jo, Yu-Jin;Yang, Hongso;Park, Sang-Won;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.130-136
    • /
    • 2020
  • Fabrication of complete denture with suction mechanism was introduced to enhance the retention and stability of denture by sealing around the denture border by forming negative pressure on the inner side of denture base during functional movement such as swallowing or masticating. Mandibular suction dentures reduce denture dislodging force during opening by taking preliminary impression without pressure on retromolar pad area in rest position. In this case, fabrication of complete denture using suction mechanism for an edentulous patient with severe alveolar bone resorption allowed us to clinically enhance retention and stability of denture and improve satisfaction of patient.

Metal base of complete denture in edentulous patient (무치악 환자에서 총의치 금속상에 대한 고찰)

  • Koo, Cheol-Ihn;Lee, Heung-Tae;Park, Chan-Ik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.197-204
    • /
    • 2002
  • Polymers are the dominant material for fabrication of denture bases. However, resin base can't fufill the patients' satisfactions completely and solve the pronunciation problem and prevent the denture fracture. In spite of many advantages, metal denture bases do not widespread in clinical practice. The main reasons are the difficulties in fabrication and additional time and cost, inability to rebase such prostheses. The use of the metal base can be one of options in complete denture treatments. This study helps, through reveiwing previous reports and literature about the metal base, metal base to be useful in the clinical application by recommend the materials, indications and advantage/disadvantage of the metal base and introduce variable designs. The clinical application of the metal base have many advantages, but the dentists have to select cases carefully and apply designs according to patient's various conditions. In conclusion, the use of the metal base can't alternate treatment of inadequate conventional complete denture. Adequate complete denture is very important for the treatment of the metal base complete denture.

Current status and future perspectives of CAD/CAM fabricated complete denture (임상가를 위한 특집 2 - CAD/CAM 기술을 이용한 총의치 제작의 현재와 전망)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.346-353
    • /
    • 2014
  • Currently, computer-aided technology becomes one of main issues in clinical dentistry. About 25 years ago, the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures leads to be able to fabricate complete denture today. The fabrication of milled complete denture prostheses with digital scanning technology may decrease the number of patient appointments. However, the precise tooth arrangement and evaluation by patient is not promising relatively. The purpose of this review was to analyze the existing literature on computer aided technology for fabricating complete denture with historical background, current status, and future perspectives. In addition, two available commercial systems were introduced.

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

A novel method of complete denture fabrication with CAD/CAM (DENTCA 시스템을 이용한 총의치 제작법)

  • Lee, Ju Hyoung;Sohn, Dong Seok;Kim, Tae Hyung
    • The Journal of the Korean dental association
    • /
    • v.51 no.6
    • /
    • pp.337-345
    • /
    • 2013
  • Currently CAD/CAM technology has been used widely in dentistry. But it has mainly been focused on fabrication of fixed partial dentures and implant-supported prosthesis. DENTCA company uses new cutting edge of CAD/CAM technology to revolutionize denture production. With developing a CAD/CAM technology of DENTCA company, it is possible to make complete dentures with minimum visits to the clinic. The aim of this article is to introduce a new denture-making method by CAD/CAM.

Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS) (Ceramill full denture system을 이용한 무치악 환자의 양악 총의치 제작)

  • Lee, Younghoo;Kwon, Kung-Rock;Pae, Ahran;Noh, Kwantae;Paek, Janghyun;Hong, Seoung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.232-237
    • /
    • 2019
  • CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.

SEVERAL METHODS OF FABRICATIONS OF INNER CROWN AND OUTER CROWN IN CONSTRUCTION OF KONUS DENTURE (다양한 Konus denture의 내관 및 외관의 제작방법)

  • Chung Jun-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.406-413
    • /
    • 2002
  • The purpose of this article is the consolidation of several methods in fabrication of Konus denture. It is different Konus denture from traditional Clasped removable partial denture in the procedures of construction. There are multiple procedures of fabrications of inner and outer crowns in the construction of Konus denture. It is important to fabricate the inner crown, the outer crown and the denture framework in construction of Konus denture. Each procedure should be performed exactly. However, there are many procedures in fabrications of them, and thus, the operator and technician bear trial and error. This article consolidate the multiple methods of fabrications of components of Konus denture. The first method is completion of inner crown, outer crown and denture after one impression taking. The second method is the procedures of cementation of inner crown, impression taking of edentulous area, and completion of outer crown and denture. The third method is the procedures or pick up impression taking of inner crown and completion of outer crown and denture on the inner crown of working cast. Each method is acceptable, but operater and technician should be accustomed with their own systemic procedures and minimize the errors in the construction of denture.

Fabrication of complete denture using conventional method and monolithic digital denture system: a case report (전통적 제작법과 모놀리식(monolithic) 디지털 의치 시스템을 이용한 상·하악 총의치 동시 수복 증례)

  • Young-Baek Park;Ga-Hyun Lee;Young-Gyun Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.6-19
    • /
    • 2024
  • With the advancement of Computer-Aided Design/Computer-Aided Manufacturing (CAD-CAM) technology, fabrication of dentures using this technology has gained popularity. As one of CAD-CAM technologies, digital complete denture system has been introduced, which fabricates complete dentures using subtractive manufacturing of monolithic block containing both the color of a denture base and an artificial tooth. In this case, two pairs of upper and lower dentures were fabricated for two patients. Two pairs of complete dentures were fabricated for a 74-year-old male and a 73-year-old female respectively by conventional denture fabrication method and digital method of milling. To obtain a digital complete denture, monolithic block (Ivotion, Ivoclar Vivadent, Schaan, Liechtenstein) was chosen for the materials to fabricate the digital complete dentures. An individual tray was designed using CAD software and manufactured by 3D printing technique. The final impression and interocclusal relationship were recorded using the fabricated individual tray. The final impression was scanned, and the complete denture design and try-in denture were 3D printed using CAD-CAM software. Subsequently, the monolithic block was milled, and the final dentures were fabricated and tried on patients. Previously mentioned two patient cases compared and analyzed stability, fit, speaking, mastication, aesthetics, and patient satisfaction of two pairs of dentures: one fabricated using CAD-CAM system and the other using traditional methods. This was performed to evaluate and report the findings from both denture-making approaches.