• 제목/요약/키워드: FTIR(Fourier Transform Infrared)

검색결과 402건 처리시간 0.042초

유기화제로 3-aminopropyltriethoxysilane 을 이용하여 라텍스법으로 제조된 SBR/organoclay 컴파운드의 혼련 온도에 따른 팽윤도 및 기계적 물성 (Swelling Ratio and Mechanical Properties of SBR/organoclay Nanocomposites according to the Mixing Temperature; using 3-Aminopropyltriethoxysilane as a Modifier and the Latex Method for Manufacturing)

  • 김욱수;박득주;강윤희;하기룡;김원호
    • Elastomers and Composites
    • /
    • 제45권2호
    • /
    • pp.112-121
    • /
    • 2010
  • 본 연구에서는 filler-rubber interaction을 향상시키기 위하여 clay의 유기화제로 3-aminopropyltriethoxysilane(APTES)을 사용하여 styrene butadiene rubber(SBR)/organoclay nanocomposite를 라텍스법으로 제조하였다. 컴파운딩시 혼련 온도에 따라 bis(triethoxysilylpropyl)tetrasulfide(TESPT)를 첨가하여 APTES에 의해 생성된 hydroxyl group과 TESPT의 ethoxy group 사이에 실란화 반응 정도에 따른 filler-rubber interaction 향상 정도를 연구하기 위하여 X-선 회절법을 이용한 silicates의 층간구조분석, 모폴로지(morphology), 적외선분광법, 팽윤도 및 기계적물성을 평가하였다. XRD분석과 TEM이미지로 관찰한 결과 silicates 층간에 APTES가 삽입된 구조를 형성하였고 고무기질 내에 organoclay의 분산이 잘 이루어졌다는 것을 알 수 있었다. 또한, 적외선 분광법을 이용하여 APTES-MMT를 분석한 결과 APTES에 의해 silicates 표면에 다량의 hydroxyl 그룹이 형성되어 TESPT의 ethoxy group과 실란화 반응이 가능하였다. SBR/APTES-MMT 컴파운드에 TESPT를 첨가시 SBR/APTESMMT 컴파운드보다 300% 모듈러스가 약 1.3 배 정도 증가하였다. 이는 APTES의 hydroxyl group과 TESPT의 ethoxy group 사이에 실란화 반응이 이루어져 filler-rubber interaction이 향상된 결과였으며, 컴파운딩시 혼련온도 증가에 따른 모듈러스 향상 효과는 미미하였다. 결과적으로 SBR/APTES-MMT 컴파운드의 경우 고무 기질 내에 silicates의 분산 정도와 가교도 증가에 따라 모듈러스가 증가하였으며, SBR/APTES-MMT 컴파운드에 TESPT를 첨가시 filler-rubber interaction이 향상되어 모듈러스가 더욱 증가하였다.

광조사 강도의 변화에 따른 광중합 복합레진의 중합반응에 관한 연구 (The Effects of Various Light Intensity on the Polymerization of Resin Composites)

  • Jun-Gyu Park;Byeong-Hoon Cho;In-Bog Lee;Hyuck-Choon Kwon;Chung-Moon Um
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.86-94
    • /
    • 2001
  • 기존의 광중합기는 높은 광강도를 제공함으로써 광중합 복합레진을 최대한 단축된 시간내의 중합을 목표로 하였다. 이러한 높은 광강도는 복합레진의 중합깊이, 중합률면에서는 우수하나 중합 반응속도가 빠름으로 인해 중합시 응력 발생이 높아진다는 일련의 보고가 있다. 최근에는 광중합 속도를 늦춤으로써 변연적합도 및 중합시 응력 발생을 낮추는 새로운 중합방법들이 제시되고 있다. 이에 본 실험에서는 광조사 강도의 변화가 광중합 복합레진의 중합반응 과정에 미치는 영향 및 중합된 복합레진의 중합률에 대한 영향을 분석하고자 하였다. 5개의 혼합형 광중합 복합레진 (Z-100, Spectrum, Z-250, Clearfil AP-X, P-60)을 사용하였으며 중합시 적용된 광조사 강도에 따라 6개의 실험군으로 정의하였다. 실험군과 이에 따른 광조사 방법은 다음과 같다. 1군은 110mW/$\textrm{cm}^2$로 40초 중합, 2군 210mW/$\textrm{cm}^2$로 40초 중합, 3군 410mW/$\textrm{cm}^2$로 40초 중합, 4군 620mW/$\textrm{cm}^2$로 40초 중합, 5군 110mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 620mW/$\textrm{cm}^2$로 30초 중합, 6군 210mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 410mW/$\textrm{cm}^2$로 30초 중합하였다. 광중합시 중합 반응 양상에 관한 분석은 시차주사 열계량기를 이용하여 37$^{\circ}C$ 항온상태에서 10분간의 열흐름곡선을 기록하였다. 기록된 열흐름곡선에서 중합 반응시 나타나는 중합열 및 최대 중합열에 이르는 시간을 기록하여 중합반응 속도를 측정하였다. 중합된 복합레진의 중합률은 Fourier Transform Infrared Spectrometer(FTIR)를 이용하였으며 2mm 두께의 복합레진 하방에서의 중합률을 측정하였다. 측정된 결과는 ANOVA 및 Student-Newman-Keuls 방법을 이용하여 유의성을 검증하였다. 실험결과 다음과 같은 결론을 얻었다. 1. 광중합 복합레진 중합시 광조사 강도가 증가할수록 중합열은 증가하였으나 통계적 유의성은 보이지 않았다 (p>0.05). 2. 최대 중합열에 이르는 시간은 광조사 강도가 증가할수록 단축되었다. 이단계 중합방법을 사용한 경우 중합반응 속도를 감소시킬 수 있음을 보였다. 3. 광조사 강도가 증가할수록 중합률은 증가하였다. 이단계 중합방법을 사용한 경우 연속적인 고광강도를 사용한 경우와 유사한 높은 중합률을 보였다. 4. 중합률면에서 광중합복합레진의 중합시 400mW/$\textrm{cm}^2$ 이상의 광강도가 필요한 것으로 나타났다.

  • PDF

도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구 (THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY)

  • 김승수;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

광반응성 작용기를 주사슬에 갖는 폴리아미드의 합성과 특성 분석 및 액정분자의 배향 특성 (Synthesis and Characterization of Polyamide Having Photoreactive Group in the Backbone and its Liquid Crystal Aligning Property)

  • 정은영;이태진;이승우
    • 폴리머
    • /
    • 제35권4호
    • /
    • pp.350-355
    • /
    • 2011
  • 고분자의 주사슬에 광반응을 할 수 있는 phenyldiacryloyl 그룹을 가지고, 곁사슬에 액정분자와 비슷한 메조겐인 biphenyl을 에테르 결합을 통해서 도입된 가용성 광반응성 폴리아미드를 합성하였다. 합성된 폴리아미드 고분자는 0.65 dL/g의 대수점도를 가지며, 일반적인 코팅 방법으로 여러 기질의 표면에 잘 도포되는 성질을 보였다. 광반응성 폴리아미드 고분자의 화학 구조는 $^1H$ NMR과 Fourier transform infrared(FTIR) spectroscopy를 이용해서 확인하였다. 합성된 고분자의 유리전이온도는 $150^{\circ}C$까지 관측되지 않았으며, 열분해 온도는 $280^{\circ}C$로 관측되어, 열안정성이 높음을 확인하였다. 합성된 폴리아미드 고분자 박막을 비편광된 자외선을 노광시켜 노광하는 에너지에 따른 변화를 조사했을 때, 좋은 광반응성을 보였다. 광반응성 폴리아미드를 이용하여 선편광된 자외선을 노광하여 제작한 액정 셀 내에서, 액정분자들은 노광된 선편광 자외선의 electric vector 방향의 수직으로 배향되는 것이 관측되었으며, 이러한 현상은 선편광 자외선의 노광량에는 무관함을 보였다. 액정 셀 내에서 액정분자들의 pretilt angle은 선편광된 자외선의 노광량에 따라 약간의 차이를 보이며 $0.2^{\circ}$에서 $0.5^{\circ}$사이의 값을 보였다.

수종 상아질 접착제의 결합강도와 중합률에 관한 연구 (A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS)

  • 김병현;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF

Effect of CQ-amine ratio on the degree of conversion in resin monomers with binary and ternary photoinitiation systems

  • Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.96-103
    • /
    • 2012
  • Objectives: This study evaluated the effect of camphorquinone (CQ)-amine ratio on the C=C double bond conversion of resins with binary and ternary photoinitiation systems. Materials and Methods: Two monomer mixtures (37.5 Bis-GMA/37.5 Bis- EMA/25 TEGDMA) with binary systems (CQ/DMAEMA in weight ratio, group A [0.5/1.0] and B [1.0/0.5]) and four mixtures with ternary system (CQ/OPPI/DMAEMA, group C [0.1/1.0/0.1], D [0.1/1.0/ 0.2], E [0.2/1.0/0.1] and F [0.2/1.0/0.2]) were tested: 1 : 2 or 2 : 1 CQ-amine ratio in binary system, while 1 : 1 ratio was added in ternary system. The monomer mixture was cured for 5, 20, 40, and 300 sec with a Demetron 400 curing unit (Demetron). After each exposure time, degree of conversion (DC) was estimated using Fourier transform infrared (FTIR) spectrophotometer (Nicolet 520, Nicolet Instrument Corp.). The results were analyzed by ANOVA followed by Scheffe test, with p = 0.05 as the level of significance. Results: DC (%) was expressed in the order of curing time (5, 20, 40, and 300 sec). Group A ($14.63{\pm}10.42$, $25.23{\pm}6.32$, $51.62{\pm}2.69$, $68.52{\pm}2.77$); Group B ($4.04{\pm}6.23$, $16.56{\pm}3.38$, $37.95{\pm}2.79$, $64.48{\pm}1.21$); Group C ($16.87{\pm}5.72$, $55.47{\pm}2.75$, $60.83{\pm}2.07$, $68.32{\pm}3.31$); Group D ($23.77{\pm}1.64$, $61.05{\pm}1.82$, $65.13{\pm}2.09$, $71.87{\pm}1.17$); Group E ($28.66{\pm}2.92$, $56.68{\pm}1.33$, $60.66{\pm}1.17$, $68.78{\pm}1.30$); Group F ($39.74{\pm}6.31$, $61.07{\pm}2.58$, $64.22{\pm}2.29$, $69.94{\pm}2.15$). Conclusion: All the monomers with ternary photoinitiation system showed higher DC than the ones with binary system, until 40 sec. Concerning about the effect of CQ-amine ratio on the DC, group A converted into polymer more than group B in binary system. However, there was no significant difference among groups with ternary system, except group C when cured for 5 sec only.

알루미노규산염 나노입자를 이용한 Poly(dimethylsiloxane) 복합매질 분리막의 기체투과 특성 (Gas Permeability through Mixed Matrix Membrane of Poly(dimethylsiloxane) with Aluminosilicate Hollow Nanoparticles)

  • 방효질;정범석
    • 멤브레인
    • /
    • 제29권1호
    • /
    • pp.51-60
    • /
    • 2019
  • 분리막 소재의 투과도와 선택도 사이의 trade-off 관계로 인해 여전히 많은 연구가 필요하다. 특히 고분자 분리막에 무기물 나노입자가 들어가 있을 때, 기체투과 거동의 학문적 이해는 여전히 부족하다. 따라서 본 연구에서는 분리막 소재로 가장 많이 사용되는 PDMS에 2~5 nm의 기공을 가지고 있으며 직경이 약 5 nm 크기의 aluminosilicate hollow nanoparticles인 allophane을 이용하여 복합매질 분리막을 제조하여 기체투과특성을 연구하였다. 대표적인 분리막 소재인 PDMS에 친수성 allophane, 그리고 나노입자에 undecylenic acid로 표면을 개질한 allophane을 막 내부에 고르게 분산시켜 함량 별로 복합매질 분리막을 제조하였다. 나노입자가 분산된 혼합매질 분리막 내에서 기체의 투과 특성을 파악하고, 이에 따른 기체투과 거동과 나노입자가 가지고 있는 기공의 역할을 평가하고자 하였다. 표면개질된 allophane을 첨가함에 따라 기체 투과도와 산소/질소 그리고 이산화탄소/메탄의 선택도가 동시에 점진적으로 향상되는 결과를 얻었다.

코팅된 무색 합성 모이사나이트의 특징 (Characterization of coated colorless synthetic moissanite)

  • 최현민;김영출;장한수;석정원
    • 한국결정성장학회지
    • /
    • 제32권1호
    • /
    • pp.7-11
    • /
    • 2022
  • 한미보석감정원은 최근에 5개의 투명한 합성 모이사나이트를 검사했다. 그 샘플들은 라운드 브릴리언트 컷의 무색, 핑크, 황색, 청색, 적색 컬러와 0.93~0.96 ct 중량을 가지고 있었다. FT-IR과 Raman 분석 결과 합성 모이사나이트임을 확인하였고, 확대검사 결과 무색을 제외한 나머지 샘플에서 코팅의 흔적이 발견되었다. EDXRF 분석 결과 무색 샘플을 제외한 모든 샘플의 코팅부분에서 Ca, Ti, Co의 미량원소가 검출되었다. 무색 샘플의 Raman 분석에서 탄소 원자의 sp3 bonding에 의해 생성되는 1332 cm-1 또는 graphite와 관련된 sp2 bonding에 의해 생성되는 ~1550 cm-1는 발견되지 않았다. 무색 샘플의 SEM 이미지에서도 코팅의 흔적은 발견되지 않았으나, TEM 이미지에서 3~8 nm의 코팅층의 존재가 발견됐다. EDX line 프로파일과 EDX elements map을 통해 무색 샘플의 코팅층을 구성하는 원소는 C, Si, O로 추정된다.

Enhanced Drug Carriage Efficiency of Curcumin-Loaded PLGA Nanoparticles in Combating Diabetic Nephropathy via Mitigation of Renal Apoptosis

  • Asmita Samadder;Banani Bhattacharjee;Sudatta Dey;Arnob Chakrovorty;Rishita Dey;Priyanka Sow;Debojyoti Tarafdar;Maharaj Biswas;Sisir Nandi
    • 대한약침학회지
    • /
    • 제27권1호
    • /
    • pp.1-13
    • /
    • 2024
  • Background: Diabetic nephropathy (DN) is one of the major complications of chronic hyperglycaemia affecting normal kidney functioning. The ayurvedic medicine curcumin (CUR) is pharmaceutically accepted for its vast biological effects. Objectives: The Curcuma-derived diferuloylmethane compound CUR, loaded on Poly (lactide-co-glycolic) acid (PLGA) nanoparticles was utilized to combat DN-induced renal apoptosis by selectively targeting and modulating Bcl2. Methods: Upon in silico molecular docking and screening study CUR was selected as the core phytocompound for nanoparticle formulation. PLGA-nano-encapsulated-curcumin (NCUR) were synthesized following standard solvent displacement method. The NCUR were characterized for shape, size and other physico-chemical properties by Atomic Force Microscopy (AFM), Dynamic Light Scattering (DLS) and Fourier-Transform Infrared (FTIR) Spectroscopy studies. For in vivo validation of nephro-protective effects, Mus musculus were pre-treated with CUR at a dose of 50 mg/kg b.w. and NCUR at a dose of 25 mg/kg b.w. (dose 1), 12.5 mg/kg b.w (dose 2) followed by alloxan administration (100 mg/kg b.w) and serum glucose levels, histopathology and immunofluorescence study were conducted. Results: The in silico study revealed a strong affinity of CUR towards Bcl2 (dock score -10.94 Kcal/mol). The synthesized NCUR were of even shape, devoid of cracks and holes with mean size of ~80 nm having -7.53 mV zeta potential. Dose 1 efficiently improved serum glucose levels, tissue-specific expression of Bcl2 and reduced glomerular space and glomerular sclerosis in comparison to hyperglycaemic group. Conclusion: This study essentially validates the potential of NCUR to inhibit DN by reducing blood glucose level and mitigating glomerular apoptosis by selectively promoting Bcl2 protein expression in kidney tissue.

이산화티타늄 담지 섬유형 활성탄소의 특성 및 악취오염물질 제어를 위한 응용 (Characteristics of Titanium Dioxide-Impregnated Fibrous Activated Carbon and Its Application for Odorous Pollutant)

  • 조완근;황은송;양성봉
    • 청정기술
    • /
    • 제17권1호
    • /
    • pp.48-55
    • /
    • 2011
  • 생활환경 수준의 이황화 메틸과 같은 황화 유기화합물의 제어를 위하여 섬유형 활성탄소-이산화 티타늄 복합재를 이용한 연구는 아직까지 보고되지 않고 있다. 따라서, 본 연구에서는 섬유형 활성탄소-이산화 티타늄 복합재를 제조하여 엑스선 회절법, 입자 비표면 측정법 및 적외선 분광법을 이용하여 광학적/표면 특성을 조사하고 활성을 평가하기 위하여 황화 이메틸의 제거 효율을 결정하였다. 섬유형 활성탄소-이산화티타늄 복합재의 물리적/표면 특성 조사에서 이 복합재가 광촉매적 활성도를 가지는 것으로 나타났다. 비표면적, 총 기공크기, 마이크로 기공크기 및 메조 기공크기의 경우에 이산화티타늄 코팅량이 증가함에 따라 감소하는 경향을 나타내었다. 그러나 평균 기공크기는 이산화티타늄 코팅량이 증가함에 따라 오히려 증가하였다. 또한, 코팅된 이산화티타늄이 섬유형 활성탄소 자체의 황화 이메틸에 대한 흡착능에 영향을 거의 미치지 않는 것으로 나타났다. 섬유형 활성탄소-이산화티타늄 복합재의 활성도 조사시험에서, 황화 이메틸의 초기 제거효율은 4가지 유량 조건(0.5, 1.0, 1.5, 2.0 L/min)에서 각각 93, 78, 71 및 57%로 나타났고, 4가지 유량 조건 모두에서 2시간째에는 제거효율이 다소 감소하였다가 그 이후에는 거의 일정하게 유지되었다. 유사 평형상태에서, 황화 이메틸 평균 제거효율은 4가지 유량조건에서 각각 75, 58, 53 및 36%로 나타났다. 한편, 섬유형 활성탄소-이산화티타늄 복합재의 표면상에서 부산물들은 관찰되지 않았다. 따라서, 본 연구에서 이용한 실험 조건에서, 섬유형 활성탄소-이산화티타늄 복합재가 부산물에 의한 큰 영향 없이 생활환경 수준의 황화 이메틸을 제어하는데 활용될 수 있는 것으로 제안된다.