• 제목/요약/키워드: FTC method

검색결과 27건 처리시간 0.021초

저 맥동 연동 펌프 기반 플로우 스루 셀 방식 용출 장치 설계 (Design of Dissolution Apparatus for the Flow-through Cell Method Based on the Low Pulsation Peristaltic Pump)

  • 조준성;정석;박상범
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.11-18
    • /
    • 2020
  • The emergence of the flow-through cell (FTC) method has made up for the limitations of previous dissolution test methods, but the high cost of the FTC dissolution devices have seriously hindered the progression of research and application of the FTC. This new design uses a peristaltic pump to simulate the sinusoidal flow rate of a piston pump. The flow profile of each peristaltic pump was sinusoidal with a pulsation of 120 ± 1 pulses per minute, and the flow rate ranged from 1.0 - 36.0 mL/min. The flow control of each channel was adjusted independently so the flow errors of the seven channels were close to 2%. The structure of the system was simplified, and the cost was reduced through manual sampling and immersing the FTC in a water bath. The dissolution rate of the theophylline and aminophylline films was determined, and good experimental results were obtained.

바질의 항산화 물질 측정에 관한 연구 (Measurement of Antioxidation Substances in Basil)

  • 서봉순;박명희
    • 동아시아식생활학회지
    • /
    • 제20권1호
    • /
    • pp.54-59
    • /
    • 2010
  • Basil is known to contain six types of polyphenols that engage in physiological activation; protocateuic acid, caffeic acid, chlorogenic acid, courmaric acid, rosmarinic acid and quercetin. In this study, the antioxidants in eight types of basil were evaluated. Specifically, the antioxidative activation of basil was evaluated based on the relationship between active oxygen scavenging (DPPH radical-scavenging), which was used as an index showing the content and functionality of the polyphenol compounds in basil, and $Fe^{2+}$/ascorbate (FTC) and 2-thiobarbituric acid (TBA). The total polyphenol content of the different types basil occurred in the following order: Dark-opal> Lettuce> Bush> Greek> Lemon> Sweet> Geno> Holy. The highest content Dark-opal was 173.3 mg, which was about three times greater than the lowest content Holy, which was 49.85 mg. In addition, DPPH radical-scavenging by Dark-opal 51%, which was the highest scavenging activity occurred in the folling order: Dark-opal> Lettuce> Bush> Greek> Lemon> Sweet> Geno> Holy. The antioxidative activation values measured using the FTC and TBA were the same as the value obtained using the DPPH method. Finally, the level of antioxidative activation measured using FTC, TBA and DPPH methods showed that the higher the content of polyphenol substance was, the stronger the antioxidative activation became.

차세대 이동망에서 멀티미디어 서비스를 고려한 FTC 방식 (Fault Tolerant Channel Allocation Scheme considering Multimedia Service in IMT-2000)

  • 박상준;이효준;조인숙;김관중;김병기
    • 한국시뮬레이션학회논문지
    • /
    • 제10권4호
    • /
    • pp.11-20
    • /
    • 2001
  • In the IMT-2000 networks, the model of micro/pico cell is suggested for transmission of multimedia service. Hence, the efficient method is required for processing of mobile calls in micro/pico cell. In the central urban area, mobile calls may be dynamically increased because of many mobile users. And microcel]/picocell size has small size, handover calls will be more increased. Therefore, many of mobile calls is occurred at a cell in the central urban area, so channel requests for these calls will be increased in the call. In this paper, we propose a scheme, FTC(Fault Tolerant Channel allocation) which is the channel management method for hard handover and new call in a mobile cell of central urban area. When available channels in the cell are consumed, the FTC investigates channel states of neighbor cells in the RNC(Radio Network Controller) or BSC (Base Station Center), and provide available channel for mobile call. The ]no scheme is analyzed and compared with existing channel management method by simulation.

  • PDF

FTC방식을 적용한 Nd:YAG 레이저의 펄스 발생 기술에 관한 연구 (A study on the Pulse generation technology of Nd :YAG laser adopting a FTC method)

  • 홍정환;김규;송금영;김희제;강욱;김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 2002
  • In this study, asolid-state laser system adopting a firing time control(FTC) method in which three flashlamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC one-chip microprocessor With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and the real-time control is possible with an external keyboard enabling various pulse shapes. In addition longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

Antioxidant Activity of Anthraquinones from Morinda elliptica

  • Ismail, Nor Hadiani;Mohamad, Habsah;Mohidin, Amran;Lajis, Nordin Hj.
    • Natural Product Sciences
    • /
    • 제8권2호
    • /
    • pp.48-51
    • /
    • 2002
  • Antioxidative properties of fifteen anthraquinone derivatives, including eleven atural anthraquinones isolated from the roots of Morinda elliptica and four from synthetic origin were evaluated using thin layer chromatography (TLC), ferric thiocyanate (FTC) and thiobarbituric acid (TBA) methods. Five of the compounds, nordamnacanthal, damnacanthal, 2-formyl-1-hydroxyanthraquinone, morindone and alizarin showed higher antioxidative activity than standard natural antioxidant, ${\alpha}-tocopherol$, on the FTC assay. Morindone and alizarin showed the strongest antioxidant activity. The results from the bioassay using TBA method correlated well with the results of the FTC method.

Observer-based Fault Tolerant Control for Constrained Switched Systems

  • Yang, Hao;Jiang, Bin;Cocquempot, Vincent
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.707-711
    • /
    • 2007
  • An observer-based fault tolerant control (FTC) method is proposed for constrained switched systems (CSS) with input constraints. A family of Lyapunov-based bounded controllers are designed to ensure that, whenever actuator faults occur at the dwell time period of each continuous mode, the mode is always within its corresponding stability region. A set of switching laws are designed to guarantee the asymptotic stability of the overall CSS. The fixed stability regions on which the FTC method is based are also relaxed by the proposed variable stability regions. An example of CPU processing illustrates the effectiveness of proposed method.

Antioxidant Activities of Fractions from Sedum sarmentosum

  • Kim, Choon-Young;Lee, Min-Young;Park, In-Shik
    • Preventive Nutrition and Food Science
    • /
    • 제11권1호
    • /
    • pp.6-9
    • /
    • 2006
  • This study was conducted to evaluate the antioxidant activity of each fraction from Sedum sarmentosum. Antioxidant activity of each fraction was measured using the DPPH radical assay, the ferric thiocyanate (FTC) method, and thiobarbituric acid (TBA) method. The antioxidant activities were then compared with that of BHT(synthetic antioxidant). The ethyl acetate and butanol fractions were found to have significant DPPH radical scavenging activity, with scavenging potencies showing 90.61 % and 87.02%, respectively. Total phenolic compound contents, determined according to the Folin-Denis method, were found to be in the order of ethyl acetate>butanol>ethanol>chloroform>aqueous fraction. From the results, we have been able to establish a positive correlation between the antioxidant activity and the total phenolic compound content of the sample. The antioxidant activity in a linoleic acid system was measured using the ferric thiocyanate (FTC) method and thiobarbituric acid (TBA) method. The ethyl acetate fraction had the highest antioxidant activity among the tested fractions. On the basis of these results, the ethyl acetate fraction provided equivalent or higher antioxidant activity as compared to BHT. These results suggest that Sedum sarmentosum is a potentially useful antioxidant for foods, cosmetics, and medicine.

내관 전침 자극이 뇌파의 상관 차원에 미치는 영향 - 정보전달 모드도해 분석법을 중심으로 - (The Effect of Electroacupuncture at the PC6 (Naegwan) on the correlation dimension of EEG)

  • 홍승원;황배연;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제20권3호
    • /
    • pp.49-60
    • /
    • 2003
  • The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6 (Naegwan) on normal humans using KarhunenLoeve decomposition method. Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different dominant frequency ranges and different origins. EEG KarhunenLoeve decomposition method exibit site-specific and state-related differences in specific frequency bands. In this study, KarhunenLoeve decomposition method was used as a measure(D2) of complexity. 30 channel EEG study was carried out in 10 subjects (10 males; $age=21.4{\pm}0.5$ years). Results : We found that the average values and standard deviations of D2 at FP1, FP2, FTC1, FTC2, TT1, TT2, T4, TCP1, P3, P4, T6, OZ channel (p<0.05) were higher than during the acupuncture treatment, and the average values and standard deviations of D2 at F3, F8 channels(p<0.05) were lowered than during the acupuncture treatment. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

Design of Fault Diagnostic and Fault Tolerant System for Induction Motors with Redundant Controller Area Network

  • 홍원표;윤충섭;김동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.371-374
    • /
    • 2004
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Preventive maintenance of induction motors has been a topic great interest to industry because of their wide range application of industry. Since the use of mechanical sensors, such as vibration probes, strain gauges, and accelerometers is often impractical, the motor current signature analysis (MACA) techniques have gained murk popularity as diagnostic tool. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is independent of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current, voltage, temperatures, vibration and speed of the motor. The DSPs share information from each sensor or DSP through DPRAM with hardware implemented semaphore. And it communicates the motor status through field bus (CAN, RS485). From the designed system, we get primitive sensors data for the case of normal condition and two abnormal conditions of 3 phase induction motor control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using CAN protocol.

  • PDF

DSP 마이크로컨트롤러를 사용한 CAN 네트워크 기반 유도전동기고장진단 시스템 설계 (Design of Network-Based Induction Motors Fault Diagnosis System Using Redundant DSP Microcontroller with Integrated CAN Module)

  • 윤충섭;홍원표
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.80-86
    • /
    • 2005
  • 유도전동기는 프로세스산업과 다른 산업분야에 광범위하게 적용되는 매우 중요한 기기이다. 프랜트를 운전함에 있어서 이의 신뢰성, 효율 및 성능은 매우 중요한 관심사항이다. 특히 유도전동기의 고장을 미리 검출하여 진단하고 고장 아래에서도 시스템이 안전하고 신뢰성 있는 성능을 가질 수 있는 고장허용제어의 실현이 매우 중요하다. 따라서 본 논문에서는 고정자전류신호 검출과 디지털 신호 프로세싱에 의한 효과적인 유도전동기의 베어링 고장검출 및 진단 기반을 가진 고장허용제어 시스템을 구축하였다. 또한 모타 고장허용제어에 기본이 되는 제어 하드웨어 구조를 제시하였으며 실험을 통하여 이 시스템의 실시간 데이터 취득 성능을 확인하였다.