• Title/Summary/Keyword: FT4

Search Result 1,580, Processing Time 0.031 seconds

Discrimination of Cultivars and Cultivation Origins from the Sepals of Dry Persimmon Using FT-IR Spectroscopy Combined with Multivariate Analysis (FT-IR 스펙트럼 데이터의 다변량 통계분석을 이용한 곶감의 원산지 및 품종 식별)

  • Hur, Suel Hye;Kim, Suk Weon;Min, Byung Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.20-26
    • /
    • 2015
  • This study aimed to establish a rapid system for discriminating the cultivation origins and cultivars of dry persimmons, using metabolite fingerprinting by Fourier transform infrared (FT-IR) spectroscopy combined with multivariate analysis. Whole-cell extracts from the sepals of four Korean cultivars and two different Chinese dry persimmons were subjected to FT-IR spectroscopy. Principle component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) of the FT-IR spectral data successfully discriminated six dry persimmons into two groups depending on their cultivation origins. Principal component loading values showed that the 1750-1420 and $1190-950cm^{-1}$ regions of the FT-IR spectra were significantly important for the discrimination of cultivation origins. The accuracy of prediction of the cultivation origins and cultivars by PLS regression was 100% (p<0.01) and 85.9% (p<0.05), respectively. These results clearly show that metabolic fingerprinting of FT-IR spectra can be applied for rapid discrimination of the cultivation origins and cultivars of commercial dry persimmons.

Synchronous determination of polycyclic aromatic hydrocarbons(PAHs) in sediment of Ulsan Bay by synchronous 2nd derivative fluorescence spectrophotometry (이차 미분 형광 분광광도법에 의한 울산만 해양 저질토양 중의 다환 방향족 탄화수소(PAHs)의 동시 분석)

  • Yoo, Kwang-Sik;Jyoung, Jy-Young;Jeong, Seon-Yi
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2004
  • Determination of some PAHs in sediments at Ulsan bay has been carried out by extraction of the components into n-hexane followed by synchronous spectrofluorimetric technique. 11 PAHs, such as acenaphthene (Ace), anthracene (Anth), benz(a)anthracene (BaA), benzo(b)fluoranthene (BbFt), benzo(k)fluoranthene (BkFt) benzo(a)pyrene (BaP), chrysene (Chry), phenanthrene (Phen), fluoranthene(Ft), perlyrene (Per), and pyrene (Pyr) in sediment samples were able to determine separately by synchronous spectrofluorimetry. Calibration curves for those components were linear for the concentration range of 0.15~166 ppb PAHs with the correlation factor of 0.9985~0.9999. The total amount of PAHs in sediments varied from 68.8 to 324.4 ng/g. The PAHs concentration was shown a tendency to increase from the outer bay to the inner basin as well the predominant contributors to the aromatic ring groups of the PAHs was 4-ring group.

Fourier Transform Infrared Spectroscopic Analysis of the Silylated Resist on Silicon Wafers in Semiconductor Lithographic Process (반도체 사진공정에서 실리콘 웨이퍼 위의 Silylated Resist의 Fourier 변환 적외선 분광분석)

  • Kang, Sung Chul;Kim, Su Jong;Son, Min Young;Park, Chun Geun
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.455-464
    • /
    • 1992
  • Using FT-IR, we determined the depth of silylated layers produced from various gas-phase-silylation conditions was proposed by using Fourier Transform Infrared (FT-IR) spectroscopic analysis. The depth of silylated layer was determined from absorbance measurments of the significant peaks (Si-O-ph, Si-C, Si-H) of FT-IR spectra with background spectrum subtraction method. And the results were compared with thickness measurments of SEM. The results were well agree with SEM. It found to be well suited for determining silylation process window.

  • PDF

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Hyper-elastic Model Haptic Feedback Using Finite Element Analysis (유한요소 해석을 이용한 초탄성체 햅틱 피드백 연구)

  • Park, Seunghyun;Kim, Jinhyun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.260-265
    • /
    • 2022
  • In this study, we establish hyper-elastic haptic feedback in a virtual environment using finite element analysis techniques and develop a Force Torque (FT) sensor utilization method for application in tele-operation environments. In general, regarding haptic feedback data, in a tele-operation environment, the user is provided with feedback according to the measured force data when the model is inserted through an FT sensor. Conversely, in a virtual environment, the press-fitting model can be expressed through the spring-damper system rather than an FT sensor to provide feedback. However, unlike rigid and the elastic bodies, the hyper-elastic body represented by a spring-damper system in a virtual environment is a simple impedance model using stiffness and damping coefficients; it is limited in terms of providing actual feedback. Thus, in this study, haptic feedback was implemented using the data obtained from POD-RBF analysis results during hyper-elastic press-fitting experiments. The haptic feedback mechanism developed in this study was verified by comparing the FT sensor feedback data measured and calculated through hyper-elastic press-fitting experiments with spring-damper feedback data. Subsequently, the POD-RBF analysis feedback was compared and evaluated against the feedback mechanism of each environment through the test subject, and the similarities between the POD-RBF analysis feedback and FT sensor data feedback were verified.

The Panax ginseng Flowering Locus T Shows Age Specific Expression Pattern in Ginseng and Increases Root Length in Transgenic Arabidopsis

  • Mohanan, Padmanaban;Myagmarav, Davajargal;Zhang, Dabing;Kim, Yu-Jin;Yang, Deok-Chun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.17-17
    • /
    • 2018
  • Panax ginseng Meyer is a perennial medicinal plant, the roots of which has been used in the traditional formulations in Oriental countries. To understand its floral transition, we isolated Flowering Locus T (FT) from ginseng, the bioinformatics analysis of PgFT has revealed a considerable homology to the higher plants, with the essential amino acids for FT function are conserved. The phylogenetic analysis has shown that the PgFT is belonged to the shrub classes of plants and closest kin to Jatropha curcas FT. The expression profiling from juvenile (2-year-old) were abundant in leaves as well as in root and was concentrated in the secondary leaflet and stem bottom in adult (4-year-old) ginseng plant tissues, moreover PgFT transcript displayed photoperiod dependent oscillation. The ectopic expression of PgFT in Arabidopsis thaliana, exhibit precocious flowering and several floral pathway integrators were up-regulated, interestingly their root length was increased in the transgenic seedlings. Therefore, we could conclude that PgFT encodes a florigen that acts as a key regulator in the flowering pathway in ginseng and hypothesize that, it might involve in the underground organ development as well. We believe our finding could provoke future studies on the physiology and development in P. ginseng.

  • PDF

The Effect of Organic Solvents on the Activity for the Synthesis of 12wt% Co-based FT Catalyst (12wt% Co 담지 FT 촉매 제조시 유기용매가 촉매활성에 미치는 영향연구)

  • LEE, JIYUN;HAN, JA-RYOUNG;CHUNG, JONGTAE;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.339-346
    • /
    • 2015
  • The synthesis of Fischer-Tropsch (FT) oil is the catalytic hydrogenation of CO to give a range of products, which can be used for the production of high-quality diesel fuel, gasoline and linear chemicals. This studied catalyst was prepared Cobalt-supported alumina and silica by the incipient wet impregnation of the nitrates of cobalt, promoter and organic solvent with supports. Cobalt catalysts were calcined at $350^{\circ}C$ before being loaded into the FT reactors. After the reduction of catalyst has been carried out under $450^{\circ}C$ for 24h, FT reaction of the catalyst has been carried out at GHSV of 4,000/hr under $200^{\circ}C$ and 20atm. From these experimental results, we have obtained the results as following; In case of $SiO_2$ catalysts, the activity of 12wt% $Cobalt-SiO_2$ synthesized by organic solvent was about 2 or 3 times higher than the activity of 12wt% $Cobalt-SiO_2$ catalyst synthesized without organic solvent. In particular, the activity of the $Cobalt-SiO_2$ catalyst prepared in the presence of an organic solvent P was two to three times higher than that of the $Cobalt-SiO_2$ catalyst prepared without the organic solvent. Effect of Cr and Cu metal as a promoter was found little. 200 h long-term activity test was performed with a $Co/SiO_2$ catalyst prepared in the presence of an organic solvent of Glyoxal solution.

Comparison of Result Between NM and LM (진단 검사의학과와 중복되는 검사들의 결과 비교, 분석 (TSH, $FT_4$, AFP, CEA, PSA))

  • Moon, Ki-Choon;Kwon, Won-Hyun;Kim, Hye-Sook;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.165-170
    • /
    • 2009
  • Purpose: Nowadays, NM (in vitro lab) and LM (TLA lab) are overlaped in almost all tests. in this case, how can NM develop continually in a keen competition with LM. we studied to find out current situation and problems after comparing NM with LM. Then, to improve our technic. Methods and meterials: We studied from October 2008 to February 2009 at department of nuclear medicine Seoul National University Bundang Hospital visited 108 patients. We assayed TSH, $FT_4$ by Ria-mat{TSH (n=23), $FT_4$ (n=19)} and AFP, CEA, PSA by manual. {AFP (n=24), CEA (n=31), PSA (n=31)}. On the other hand, LM was measured by TLA system. Results: NM was similar to LM (value of AFP), NMLM (value of PSA,TSH), NM$\leqq$LM (value of $FT_4$ in range 0.01~1.00 ng/mL), NM$\geqq$LM (value of $FT_4$ in range 1.00~6.00 ng/mL) Conclusions: There was no test which result showed big difference remarkably, but several tests have some difference totally or partly. It means that there is possibility to judge wrongly (normal patient->abnormal, abnormal->normal). So, we need to consider always when we report the result.

  • PDF