• Title/Summary/Keyword: FT

Search Result 3,819, Processing Time 0.023 seconds

The Quantitative Analysis of SB Latex Contents in Coating Color and Coating Layer of Coated Paper Using FT/Raman Spectroscopy (FT/RAman을 이용한 도공액과 도공지의 도공층 내의 SB Latex 정량분석)

  • 이복진;정순기;윤동호;마금자
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.16-22
    • /
    • 1999
  • The quantitative analysis of SB latex contents in coating color and coated paper was investigated with FT/Raman spectroscopy. From the measured FT/IR and FT/Ramon spectra, the peaks of coating color were compared with those of each compoents . Calibration curves were obtained by the area of latex peaks and PLS method of QuantIR program. The relation of predicted values in PLS method and actual values in coating mixtures and coating layer was examined. The components of coating layer in coated paper were investigated by EDS , X-mapping and SEM, The contents of latex in z-direction were calculated in the coating layer of unknown coated paper. The latex concentration measurements of Top layer and Pre layer in double coated paper show that each layer has different value. In single coated paper, it is clear that the latex concentration is highest at the surface and decreases with an increase of depth. From those results it is indicated that the latex migrates to the coated surface. The result of this study may be applied to the binder migration study and the quality control in paper mill.

  • PDF

Effect of $N_2$-backflushing Time in Carbon Ceramic UF & MF System for Paper Wastewater Treatment

  • Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.34-41
    • /
    • 2005
  • The wastewater discharged from a paper plant was filtrated by 3 kinds of tubular carbon ceramic UF and MF membranes with $N_2$-backflushing. The filtration time (FT) was fixed at 8 min or 16 min, and $N_2$-backflushing time (BT) was changed in 0${\~}$60 sec. The optimal condition was discussed in the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux (J/Jo) and resistance of membrane fouling ($R_f$). In the viewpoints of $V_T$, J/Jo and $R_f$, the optimal $N_2$-BT was 40 sec at both FT for M9 (MWCO: 300,000 Daltons) and C005 ($0.05{\mu}m$) membranes. However, for C010 ($0.1{\mu}m$) it was 10 sec at FT=8 min, and 20 sec at FT=16 min in the viewpoints of J/Jo and $R_f$, and 5 sec at both FT in the viewpoints of $V_T$. It means that the short $N_2$-BT could reduce the membrane fouling and recover the permeate flux sufficiently for MF membrane having a large pore size as C010. Average rejection rates of pollutants were higher than $99.0\%$ for turbidity and $22.8{\~}59.6\%$ for $COD_{cr}$, but rejection rates of total dissolved solid (TDS) were lower than $8.9\%$. Therefore, the low turbidity water purified in our system could be reused for paper process.

Compositional Characterization of Petroleum Heavy Oils Generated from Vacuum Distillation and Catalytic Cracking by Positive-mode APPI FT-ICR Mass Spectrometry

  • Kim, Eun-Kyoung;No, Myoung-Han;Koh, Jae-Suk;Kim, Sung-Whan
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.41-44
    • /
    • 2011
  • Molecular compositions of two types of heavy oil were studied using positive atmospheric pressure photoionization (APPI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Vacuum gas oil (VGO) was generated from vacuum distillation of atmospheric residual oil (AR), and slurry oil (SLO) was generated from catalytic cracking of AR. These heavy oils have similar boiling point ranges in the range of 210-$650^{\circ}C$, but they showed different mass ranges and double-bond equivalent (DBE) distributions. Using DBE and carbon number distributions, aromatic ring distributions, and the extent of alkyl side chains were estimated. In addition to the main aromatic hydrocarbon compounds, those containing sulfur, nitrogen, and oxygen heteroatoms were identified using simple sample preparation and ultra-high mass resolution FT-ICR MS analysis. VGO is primarily composed of mono- and di-aromatic hydrocarbons as well as sulfur-containing hydrocarbons, whereas SLO contained mainly polyaromatic hydrocarbons and sulfur-containing hydrocarbons. Both heavy oils contain polyaromatic nitrogen components. SLO inludes shorter aromatic alkyl side chains than VGO. This study demonstrates that APPI FT-ICR MS is useful for molecular composition characterization of petroleum heavy oils obtained from different refining processes.

Effect of Prolonged Running-induced Fatigue on Free-torque Components

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the differences in FT (free-torque) components between non-fatigue and fatigue conditions induced by prolonged running. Methods: Fifteen healthy runners with no previous lower-extremity fractures ($22.0{\pm}2.1$ years of age) participated in this study. Ground reaction force data were collected for the right-stance phase for 10 strides of 5 and 125-min running periods at 1,000 Hz using an instrumented force platform (instrumented dual-belt treadmills, Bertec, USA) while the subjects ran on it. The running speed was set according to the preferences of the subjects, which were determined before the experiment. FT variables were calculated from the components of the moment and force output from the force platform. A repeated-measures one-way ANOVA was used to test for significant differences between the two conditions. The alpha level for all the statistical tests was 0.05. Results: The absolute FT at the peak braking force was significantly greater after 5 mins of running than after 125 mins of running-which was regarded as a fatigued state-but there were no significant differences in the absolute peak FT or impulse between the conditions. Conclusion: The FT variables in the fatigue condition during prolonged running hardly affect the tibial stress syndrome.

Determination of NaOH, $Na_2CO_3$ and $Na_2S$ Concentration in a Naphtha Cracking Process by FT-NIR Spectroscopy (FT-NIR를 이용한 Naphtha Cracking 공정중 NaOH, $Na_2CO_3$$Na_2S$ 정량분석)

  • Jang, Mijin;Kim, Hyunwook;Cho, Ilyoung
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.448-451
    • /
    • 1998
  • The feasibility of using FT-NIR (Fourier Transform Near Infrared) spectrometer to measure NaOH, $Na_2CO_3$ and $Na_2S$ concentration in a naphtha cracking process, and an outline of the method development to identify spectral feature of the hydroxide whose band is overlapped by a strong water absorption were demonstrated. For measuring NaOH, $Na_2CO_3$ and $Na_2S$, FT-NIR spectrometer is a rapid and possible alternative to the current titration method with a standard deviation of 0.1.

  • PDF

Prediction of Suitable Site to Measure Abdominal Skin Fold Thickness and Correlation among Obesity Indicators in Patients with Type 2 Diabetes Mellitus (제2형 당뇨병 환자에서 피부두겹두께의 측정부위 예측 및 비만지표들 간의 관련성)

  • Hwang, Moon Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.22 no.1
    • /
    • pp.36-44
    • /
    • 2020
  • Purpose: The purpose of this study was to predict measuring site suited for abdominal skin fold thickness (ASFT) by measuring the distribution of abdominal subcutaneous fat thickness (AScFT) and ascertain the correlations among obesity indicators. Methods: The size of analysis materials was 124 secondary data measured by ultrasonic device, bioelectrical impedance analyzer and caliper. Data were analyzed using t-test, and Pearson's correlation. Results: The average of AScFT was 10.63± 6.79mm with its range 1.39-36.16 mm, and AScFT of female and of central parts were thicker than those of male and outer parts in the abdomen. The average of ASFT was 29.26±12.59 mm. Site 5 on Figure 1 was most similar to the average of AScFT in both sexes. Body mass index (BMI) and waist hip ratio (WHR) were 23.65±3.98 and 0.88±0.05 respectively. The body weight, BMI, WHR, visceral fat, ASFT vs AScFT revealed in significant correlation (r= .29, r= .55, r= .39, r= .33. r= .29). Conclusion: BMI and WHR seem more useful than other obesity indicators, when obesity control is necessary for Type 2 diabetes patients. Site 5 on Figure 1 is most suitable site to measure ASFT.

A quantitative determination of surfactant mixtures by FT-IR (FT-IR을 이용한 계면활성제 혼합물의 정량)

  • 최종근;노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.2
    • /
    • pp.129-139
    • /
    • 1995
  • To confirm the usefulness of partial least-squares(PLS) and multiple scattering correction(MSC) method for quantitation of surfactants in [quantitative methods using FT-lR, reconsitituted mixtures of LAS, MES and ELA-9 were tested. Each mixture was dissolved in 50% EtOH, dried, and applied to the KBr cell. From the IR spectra of these mixture, the variance spectrum was obtained. After repeated calibrations for the various regios of this spectrum, we found that 1245-1130cm-1 and 1070-1010cm-1 showed the strong correlation with each component of the sample mixture: all the correlation coefficients were 1.000 and quantitative errors did not exceed 0.32%. From this result, we concluded that PLS method and MSC method are very useful and can be successfully applied to Quality control.

  • PDF

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

A Fault Detection Isolation and Compensation Scheme using Finite-time Fault Detection Observers (유한시간 수렴 고장검출관측자를 이용한 고장검출식별 및 보상기법)

  • Lee, Kee-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1802-1808
    • /
    • 2009
  • A fault detection observer with finite time convergence characteristics(FT_FDO) is proposed and applied to a fault detection isolation system for a dynamic control system. The FT_FDO is a kind of dual state-observer scheme that provides with the state estimates insensitive to a specified fault and the corresponding fault estimate. The state estimates are processed to get the residual that will be logically compared with other residuals to detect and isolate the fault of interest, and the fault estimate may be used for fault compensation. The FDIS employing the FT_FDOs can be considered to be a multiple observer schemes(MOS) in which FT_FDOs are parallelly driven to generate a set of residuals to be compared each other. Due to the finite time convergence characteristics of the FT_FDO, the predetermined detection delay can be considered in the design stage of FDIS so that any fault of interest can be detected and identified in that time. It evidently resolves a well known difficulty of threshold selection owing to the transient responses of the fault detection observers(FDO) employed in FDIS. An FDIS is constructed for instruments(2-sensor, 1-actuator) in an inverted pendulum control system, and simulations are performed to show the performance of the FDIS and fault tolerant control system.

FT-IR Spectroscopic Study of Preparation of Lead Zirconium Titanate (PZT) by Sol-Gel Processing

  • 오영재;황인욱;심인보;김용록
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.6
    • /
    • pp.588-594
    • /
    • 1997
  • Gelation time, gel structure and volatility of by-products during gelation of PZT sol-gel processing were investigated by FT-IR spectroscopy. FT-IR spectroscopic study was performed on PZT gels with the various H₂O contents (1, 2 and 3 mol) and the several types (HNO₃, NH₄OH) and amounts (0.1, 0.2 mol) of catalysts, monitoring temporal (0, 1, 3, 10 weeks, 3 months and 3 years) and thermal (100-700 ℃) changes of FT-IR spectra. The interpretation of temporal change of the spectra revealed two trends. One is under the condition of 1 mol H₂O, 1 mol H₂O+0.1 mol HNO₃, 3 mol H₂O and the other is for 1 mol H₂O+0.1 mol NH₄OH, 2 mol H₂O, 1 mol H₂O+0.2 mol HNO₃. The gel structures and the gelation times for these conditions were discussed in comparison with the reported results of SiO₂, and we suggested the reaction mechanisms for these structural characteristics. Thermal variation of FT-IR spectra was interpreted as the evolution processes of gel by investigating the evaporation of solvent and the decomposition of organic residues.