• Title/Summary/Keyword: FT(Fault Tree)

Search Result 27, Processing Time 0.023 seconds

A Review of FTA Methods for FT Construction & Evaluation(I) (FT구축 및 평가를 위한 FTA방법의 일반적 고찰(I))

  • 박주식;김길동;강경식;박상민
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.3
    • /
    • pp.13-25
    • /
    • 2000
  • This paper reviews and classify fault-tree analysis methods developed since 1960 for system safety and reliability. Fault-tree analysis is a useful analytic tool for the reliability and safety of complex systems. The literature on fault-tree analysis is, for the most part, scattered through conference proceedings and company reports. This paper classify the literature according to system definition, fault-tree construction, qualitative evaluation, quantitative evaluation, and available computer codes for fault-tree analysis.

  • PDF

A Study on the rapid calculating of reliability for Fault Tree (FT의 빠른 신뢰도계산을 위한 연구)

  • 이일재;이광원
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.180-190
    • /
    • 1997
  • A new method in the fault tree analysis (FTA) for the reliability calculation is suggested. Two steps are necessary in traditional method in evaluation of the occurrence probability of top event in fault tree (FT). The first step is to find the minimal outsets, and the second one is to substitute the result into the poincare equation. In order to reduce the enormous computing time of this method, lots of rapid algorithms have been developed. Almost of all achievements were, however, based on the partial structural properties of FT. In this paper, the FT is transformed to a non-linear graph G which has the same minimal outsets of original n, and then the reliability is calculated using the domination theory. In this new method, the required number of equation terms are at most $2^n$ (n is node number of graph G), while $2^m$-1 (m is the number of minimal cutsets) calculation terms are required in the poincare equation in traditional method. Since m>>n in general. our new method reduces the calculation time significantly.

  • PDF

Development of Automatic Fault Tree Construction System using Digraph (Digraph를 이용한 Fault Tree 자동합성시스템의 개발)

  • Jung, Won-Seok;Lee, Geun-Won;Moon, Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.393-393
    • /
    • 2000
  • FTA(Fault Tree Analysis) is a safety analysis method that focuses on one particular accident or main system failure and provides a method of determining causes of that event. While most of the statistical and cut set analysis have been automated, actual construction of the fault-tree is usually done manually. Manual construction of the fault-tree is extremely time consuming and it requires high level of expertise and experience. In addition to the time involved, different analyst often produces different fault-trees either by incorrect logic or omission of certain events. Automatic fault-tree construction system can be efficient in solving above problems. This study presents a new Digraph-FT conversion algorithm that leads automatic FTA system.

  • PDF

Comparison of event tree/fault tree and convolution approaches in calculating station blackout risk in a nuclear power plant

  • Man Cheol Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.141-146
    • /
    • 2024
  • Station blackout (SBO) risk is one of the most significant contributors to nuclear power plant risk. In this paper, the sequence probability formulas derived by the convolution approach are compared with those derived by the conventional event tree/fault tree (ET/FT) approach for the SBO situation in which emergency diesel generators fail to start. The comparison identifies what makes the ET/FT approach more conservative and raises the issue regarding the mission time of a turbine-driven auxiliary feedwater pump (TDP), which suggests a possible modeling improvement in the ET/FT approach. Monte Carlo simulations with up-to-date component reliability data validate the convolution approach. The sequence probability of an alternative alternating current diesel generator (AAC DG) failing to start and the TDP failing to operate owing to battery depletion contributes most to the SBO risk. The probability overestimation of the scenario in which the AAC DG fails to run and the TDP fails to operate owing to battery depletion contributes most to the SBO risk overestimation determined by the ET/FT approach. The modification of the TDP mission time renders the sequence probabilities determined by the ET/FT approach more consistent with those determined by the convolution approach.

A Study on Real time Multiple Fault Diagnosis Control Methods (실시간 다중고장진단 제어기법에 관한 연구)

  • 배용환;배태용;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.457-462
    • /
    • 1995
  • This paper describes diagnosis strategy of the Flexible Multiple Fault Diagnosis Module for forecasting faults in system and deciding current machine state form sensor information. Most studydeal with diagnosis control stategy about single fault in a system, this studies deal with multiple fault diagnosis. This strategy is consist of diagnosis control module such as backward tracking expert system shell, various neural network, numerical model to predict machine state and communication module for information exchange and cooperate between each model. This models are used to describe structure, function and behavior of subsystem, complex component and total system. Hierarchical structure is very efficient to represent structural, functional and behavioral knowledge. FT(Fault Tree). ST(Symptom Tree), FCD(Fault Consequence Diagrapy), SGM(State Graph Model) and FFM(Functional Flow Model) are used to represent hierachical structure. In this study, IA(Intelligent Agent) concept is introduced to match FT component and event symbol in diagnosed system and to transfer message between each event process. Proposed diagnosis control module is made of IPC(Inter Process Communication) method under UNIX operating system.

  • PDF

Reliability analysis of nuclear safety-class DCS based on T-S fuzzy fault tree and Bayesian network

  • Xu Zhang;Zhiguang Deng;Yifan Jian;Qichang Huang;Hao Peng;Quan Ma
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1901-1910
    • /
    • 2023
  • The safety-class (1E) digital control system (DCS) of nuclear power plant characterized structural multiple redundancies, therefore, it is important to quantitatively evaluate the reliability of DCS in different degree of backup loss. In this paper, a reliability evaluation model based on T-S fuzzy fault tree (FT) is proposed for 1E DCS of nuclear power plant, in which the connection relationship between components is described by T-S fuzzy gates. Specifically, an output rejection control system is chosen as an example, based on the T-S fuzzy FT model, the key indicators such as probabilistic importance are calculated, and for a further discussion, the T-S fuzzy FT model is transformed into Bayesian Network(BN) equivalently, and the fault diagnosis based on probabilistic analysis is accomplished. Combined with the analysis of actual objects, the effectiveness of proposed method is proved.

Electrical Fire Hazards Analysis of Electric Iron and Heater Using Fault Tree Analysis

  • Hong, Sung-Ho
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • The primary goal of this study is to analyze fire hazards of electric home appliances such as electric iron and electric heater using fault tree analysis(FTA). A fault tree(FT) is constructed and used to analyze fire hazards in electric home appliances. The fault tree is built from events that may occur in electric home appliances. The failure rate of basic events are derived from the value of experimental results and reference. And an algorithm analyzing fire in electric home appliances is suggested. We show how fault tree analysis, carried out by means of failure rate, is able to diagnose fire hazards of electric home appliances in a precise manner. We present numerical results such as fire probability of electric home appliances, importance measure, fire cause, etc. It can be helpful in preventing the fire hazards in electric home appliances.

INTERACTIVE SYSTEM DESIGN USING THE COMPLEMENTARITY OF AXIOMATIC DESIGN AND FAULT TREE ANALYSIS

  • Heo, Gyun-Young;Lee, Tae-Sik;Do, Sung-Hee
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.51-62
    • /
    • 2007
  • To efficiently design safety-critical systems such as nuclear power plants, with the requirement of high reliability, methodologies allowing for rigorous interactions between the synthesis and analysis processes have been proposed. This paper attempts to develop a reliability-centered design framework through an interactive process between Axiomatic Design (AD) and Fault Tree Analysis (FTA). Integrating AD and FTA into a single framework appears to be a viable solution, as they compliment each other with their unique advantages. AD provides a systematic synthesis tool while FTA is commonly used as a safety analysis tool. These methodologies build a design process that is less subjective, and they enable designers to develop insights that lead to solutions with improved reliability. Due to the nature of the two methodologies, the information involved in each process is complementary: a success tree versus a fault tree. Thus, at each step a system using AD is synthesized, and its reliability is then quantified using the FT derived from the AD synthesis process. The converted FT provides an opportunity to examine the completeness of the outcome from the synthesis process. This study presents an example of the design of a Containment Heat Removal System (CHRS). A case study illustrates the process of designing the CHRS with an interactive design framework focusing on the conversion of the AD process to FTA.

FAULT-TREE-BASED RISK ASSESSMENT FOR DYNAMIC CONDITION CHANGES

  • Kang, Hyun-Gook;Jang, Seung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.123-128
    • /
    • 2007
  • In order to apply a static fault-tree (FT) method to a system or a plant whose configuration changes dynamically, condition gates and a post processing method are used to effectively accommodate these changes. An operator's performance change, which can be caused by these configuration changes, should also be considered to assess the risk to a plant in a more realistic manner. This study aims to develop an integrated framework to accommodate various configuration changes and their effect on an operator’s performance by using the FT model. We applied a condition-based human reliability assessment (CBHRA) method to consider various conditions endured by an operator. That is, we integrated the CBHRA method with the conventional post processing method for modeling the system configuration changes. The effect of the condition monitoring systems installed in a plant is also considered. In this study, we show an example application of the integrated framework to a probabilistic safety assessment for the shutdown phase of a nuclear power plant.

Safety Verification Method Based on Fault Tree Analysis (FTA를 이용한 안전성 검증에 대한 고찰)

  • 김은미
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10b
    • /
    • pp.582-584
    • /
    • 1998
  • 객체 지향 설계 명세를 대상으로한 시스템의 안전성에 대한 검사를 하여, 표(Table)조작에 기초한 검증법을 제안하였다[4]. 제안한 검증법에서는 전문 분야별로 준비된 안정성 기준(Safety Standard)과 노우하우(Knowhow)를 이용하여, 안전성에 관한 이벤트(Event)와 액션(Action)의 관계표를 작성하였다. 그러나, 많은 실제 개발 현장에서는 실제 존재하는 안전성 기준의 부족 등으로 인하여, 이러한 검증법의 기용이 어렵다는 문제점이 있다. 이에 본 논문에서는 신뢰성 분석의 한 방법인 FTA(Fault Tree Analysis)의 FT(Fault Tree)도를 이용한 안정성 체크리스트(Check list)를 작성하여, 이를 바탕으로 관계표를 작성하는 새로운 방법을 제안하고자 한다.