Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

Breakdown Characteristics for Insulation Design of HTS Transformer in Liquid Nitrogen

  • J.M. Joung;S.M. Baek;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.38-42
    • /
    • 2003
  • HTS transformer is promising one of HTS power applications to be commercialized in the near future. To realize the applications, insulation technology in the coolant, liquid nitrogen, should be established. So breakdown characteristics should be considered at insulation components; turn-to-turn, layer-to-layer, winding-to-winding, were investigated. Firstly breakdown strengths of Kapton films were compared with Kraft paper these are as turn insulator. And next the characteristics of surface flashover on FRP were measured and the influence on breakdown strength of bubble generated with joule heat was discussed with the shape of cooling channel between layers. Finally barrier effect at winding-to-winding was discussed.

콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가 (Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements)

  • 박성태;박준영;이재훈;김형배
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

제작성을 개선한 하이브리드 FRP-콘크리트 합성말뚝의 압축거동 (Compression Behavior of Manufacturability Enhanced FRP-Concrete Hybrid Composite Pile)

  • 이영근;박준석;김선희;김홍락;윤순종
    • Composites Research
    • /
    • 제26권1호
    • /
    • pp.66-71
    • /
    • 2013
  • 말뚝은 상부구조물에 작용하는 하중을 지반에 전달하는 구조요소로서, 일반적으로 말뚝기초는 지중 또는 수면 아래 지중에 건설된다. 이러한 환경은 부식 또는 염해를 유발하여 말뚝에 손상을 야기한다. 지중 및 수중 구조요소인 말뚝이 손상될 경우, 손상에 따른 내구성을 평가하기 어려우며 추가적인 보수보강 및 유지관리 또한 어렵다. 이 연구에서는 말뚝기초의 내구성과 제작성을 개선하기 위하여 하이브리드 FRP-Concrete 합성말뚝(HCFFT)을 제안하였다. 제안된 HCFFT에 대한 유한요소해석과 실험을 실시하여, 이를 바탕으로 HCFFT의 최대하중 추정식을 제안하였다. 또한, 제안된 HCFFT의 제작과정에서의 문제점을 개선한 새로운 형태의 HCFFT의 형태를 제안하고, 유한요소해석을 실시하여 동일한 직경의 PHC 말뚝과 강관말뚝의 축방향 압축력을 HCFFT 말뚝의 축방향 압축력과 비교하여 HCFFT 말뚝의 장점을 확인하였다.

18kV 배전용 피뢰기의 구조에 따른 온도특성 (Temperature Characteristics with Structure of 18kV Lightning Arresters for Distribution System)

  • 조한구;윤한수;이운용;김석수;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1125-1128
    • /
    • 2004
  • This paper presents the temperature characteristics with structure of 18 kV lightning arresters for distribution. Three types of polymer arresters were fabricated and ceramic type arrester was also ready to investigate. Below $100^{\circ}C$, three types of polymer arresters exhibited almost the same leakage current value, but above $100^{\circ}C$, polymer arrester that arrester module was injected into polymer housing with grease exhibited the highest leakage current and the arrester with the lowest leakage current was the arrester that silicon rubber was directly injected to arrester module. The rising of leakage current of polymer arrester with grease was because of existing grease between FRP winding and silicon housing, and reducing the insulation characteristics of the grease. All polymer arresters exhibited the same temperature characteristics but ceramic typr arrester was slower than polymer arrester in heat emission despite lowest leakage current. It was thought that the air layer between ZnO varistor blocks and ceramic housing prevented the heat emission. However, in spite of the difference of the structure, the variation of the surface temperature of all arresters exhibited the same result.

  • PDF

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

폴리머 피뢰기 애관 개발에서의 기밀기술 (Sealing Technology For Polymer Arrester Housed Development)

  • 황명근;김광호;박남식;김인성;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.754-756
    • /
    • 1996
  • In this paper, polymer housing arrester has very good characteristics in design versatility as well as excellent resistance to moist ingress and pollution performance. For the presented of the characteristics evaluation and technology of disk spring and knuckle structure of FRP to filament winding seems to protect the arrester elements from moisture absorption. The achievement in the research and technology will contribute to the showed very good characteristic in adhesion of terminal cap and FRP cylinder for outdoor arresters and domestic products of high voltage power distribution arrester.

  • PDF

6.6kV00A급 유도형 초전도한류기의 DC 리액터용 고온 초전도 솔레노이드의 제작 (Fabrication of the HTS Solenoid for DG Reactor of 6.6kV/200A Inductive Superconducting Fault Current Limiter)

  • 김현석;안민철;이승제;이안수;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.230-233
    • /
    • 2003
  • This paper deals with the fabrication of high temperature superconducting(HTS) solenoid for DC reactor of 6.6㎸/200A inductive superconducting fault current limiter(SFCL). The winding machine which is suitable to wind HTS wire was manufactured. The proper inductance was calculated by circuit simulation and G10-FRP bobbin was fabricated with this inductance, HTS solenoid was wound by using the winding machine. The V-I characteristic of completed DC reactor in sub-cooled nitrogen(65K) was measured. The full quench current of this magnet is about 490A.

  • PDF

초전도 변압기의 절연기반 연구 (A Study on the Insulation Basis of Hts Transformer)

  • 천현권;곽동순;윤문수;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.639-642
    • /
    • 2005
  • HTS Transformer developing is developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects. Therefore, we prepared the model, that is Z continuous winding from Kapton insulated Cu tape for a small simulated the HTS transformer. For the development of electrical insulation design of a HTS transformer with Z continuous winding, we have been discussed insulation composition and investigated breakdown characteristics such as breakdown of liquid $N_2(LN_2)$, polymer and surface flashover on FRP and breakdown-surface combination in $LN_2$. Also we have been designed and manufactured a bobbin that has spiral slot for the Z continuous winding. The Z continuous winding mini-model from Kapton film insulated Cu tape for simulated 22.9kV class HTS transformer has been constructed using 0.1 % breakdown strength obtained by Weibull distribution. The widing model was measured their insulation characteristics such as ac (50kV, 1min) and impulse (154kV, $1.2\times50{\mu}s$ full wave, 3 times) withstand test and its excellent performance was confirmed.