• 제목/요약/키워드: FRP sheet

검색결과 133건 처리시간 0.022초

연속섬유 시트로 보강된 RC 부재의 모서리 형상에 따른 보강 효율에 관한 연구 (Strengthening Efficiency for the Various Corner Shapes of RC Member confined with Continuous Fiber Sheets)

  • 고훈범;이진섭
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.113-119
    • /
    • 2008
  • Recently, fiber reinforced polymers(FRP) composite materials are used extensively in the rehabilitation of concrete structural members. A main application is to wrap beams and columns using the continuous fibers sheets to improve their strength and ductility. The corner chamfering affects significantly the performance of the continuous fibers sheets, and could lead to environmental problem with waste and dust. The main purpose of this paper is to verify the effect of corner conditions on the strength of the continuous fiber sheets, and to introduce new attached components which can avoid environmental problem. A total of 15 specimens were tested and carefully checked for three types of continuous fiber sheets(carbon, glass, and aramid) and three types of corner conditions(non-chamfering, chamfering, and device attaching). It is proved that the devices proposed in this research have some capabilities to use for RC member. But additional research will be needed for commercializing.

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

Silicate계 콘크리트 함침제 도포에 따른 부착특성 및 공극변화 (Adhesion Characteristic and Porosity Change of Alkali Silicate Impregnant of Concrete)

  • 송훈;추용식;이종규;임영철
    • 한국세라믹학회지
    • /
    • 제47권4호
    • /
    • pp.276-282
    • /
    • 2010
  • There are the impregnating layer formation by surface protective materials or impregnants and the adhesion method by polymer, FRP sheet or steel plate in the surface protective method of concrete structure. The surface impregnation method by impregnants improves the durability of concrete structure by modifying the structure of the concrete surface and also have a merit that can be shortly applied in place without the decrease of concrete surface appearance and is easily applied again. This study is interested in manufacturing the concrete surface impregnants including lithium and potassium silicate for the repair of the exposed concrete and the color concrete requiring the advanced function in view of the concrete appearance. The durability and porosity properties was tested for the review of application. The result of this study show that the effective content of silicate ranges 5 to 20% and the separate application of the first impregnant and the second impregnant is effective for the optimum performance. The adhesion in tension is slightly increased but the reinforcement of concrete substrate is slight. So, the concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

보강된 노후 구조물 파괴거동 예측을 위한 수치해석기법 개발 (Numerical Analysis of Fracture Behavior in Aged RC Structures)

  • 신승교;고태호;김문겸;임윤묵
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1031-1036
    • /
    • 2000
  • In this study, a numerical simulation that can effectively predict the strengthening effect of repaired aged RC structures is developed using the axial deformation link elements. In repaired structures, concrete and interface are modeled as quasi-brittle materials. An elastic-perfectly plastic constitutive relationship is introduced for reinforcing bars. Also, a linear-elastic relationship for repair materials such as FRP or CFS. Structural deterioration in terms of corrosion of steel rebar is considered. The interfacial property between steel and concrete which is reduced by corrosion of steel rebar is obtained by comparing numerical results with experimental results of pull out tests. Obtained values are used in repaired reinforced concrete structures under flexural loading conditions. To investigate strengthening effect of the structures repaired with carbon fiber sheet(CFS), repaired and unrepaired RC structures are analyzed numerically. From analysis, rip-off, debonding and rupture failure mechanisms of interface between substrate and CFS can be determined. Finally, strengthening effect according to the variation of interfacial material properties is investigated, and it is shown that interfacial material properties have influence on the mechanical behavior of repaired structure systems Therefore, the developed numerical method using axial deformation link elements can use for determining the strengthening effects and failure mechanism of repaired aged RC structure.

탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성 (Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss)

  • 서수연;윤현도;최기봉
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.795-802
    • /
    • 2007
  • 최근 탄소섬유를 보강재로 사용한 구조 부재의 휨 거동에 관한 많은 연구가 진행되어 왔으나, 대부분의 연구는 FRP를 이용한 설계법의 개발과 구조 성능 평가에 초점이 맞추어져 있기 때문에 장기적으로 보강재 또는 부착 상태의 변화에 따른 구조 성능 변화 등과 같은 현상을 반영하기에는 아직까지 부족한 점이 있다. 이에 따라 현재까지 보강된 FRP의 성능 저하에 따른 구조물의 구조 내력 저하에 대하여 구체적인 방안이 제시되기 위해서는 많은 사례 조사와 물성 변화를 고려한 구조물의 거동 특성 변화에 대한 지속적인 연구가 요망된다. 본 연구에서는 시간에 따라 저하되는 부착률의 변화에 따른 구조 성능의 변화를 관찰하고자, CFS의 부착률 변화와 부착 형태의 차이에 의한 거동 차이를 실험을 통해 밝히고, 기존 제안식을 이용하여 부착률과 부착 형태 차이에 따른 구조 성능 변화를 예측함으로써 CFS로 보강된 이후 부착률이 저하된 경우에 대한 거동 특성 평가방안을 제시하였다. 또한, 비선형 단면 해석을 통하여 실험 결과와 비교 검토하여 적정 해석 방법을 제시하였다.

초(初)·중(中)·고등학생(高等學生)의 체질검사(體質檢査) 실태분석(實態分析) - 1차(次) 건강사정(健康査定)을 중심(中心)으로- (The Analysis of the Physical Examination of Elementary & Secondary School Students -Centering on the Primary Health Assessment-)

  • 이강순;정연강;박계숙
    • 한국학교보건학회지
    • /
    • 제7권1호
    • /
    • pp.9-28
    • /
    • 1994
  • This study is to investigate the status and problems in the anual physical examination in elementary & secondary schools. The study helps the introduction of health assessment. Two hundreds and forty nurse teachers of elementary & seconcary school in Seoul received in-service traomong fpr 20 daus frp, September 7 to September 27, 1992. Questionnaires were given to the 240 teachers and the number of collected questionnaire is 112. The result of the questionnaire analysis is like the following. First, the answered teachers aged 35~39, 36.6%; experience 6~10 years 37.5%; the number of class 31~40, 28.6%. Among the answered of the school doctors is practicioners. The doctors major subjects are 26.8% of internal medicine and 35.7% of surgery. Second, in elementary & secondary school nurse teachers received in-service training for the primary health assessment. And then 37.5% of schools practiced the health assessment. The term of the health assessment is largely a-year-length, occurately its rate of schools have practiced the assessment reaches 81.0%. The number of health assessment are consist of eyes, nose, ear, throat, skin, spine, heart and other abnormal regions and diseases all over the body. And 83.3% of the rate of the health assessment includes all these contents. The period of the health assessment is 7 to 28 days. Third, the physical examination conducted by school doctors is 91.0%. The method is various; one is 56.6% of the students who checked first by he nurse teacher. The number of 15.1% of the schools is directly checked by the school doctor. The invited medical doctors are divided into two categories. The number of general physician is 61.9%. Contrary to that school doctors are 38.1%. The contents of the medical examination is all the items printed on the medical examination sheet. To follow the medical examination sheet the number of school is 59.6%. Eyes, throat, skin and heart etc. partly medical examination is 40.4%. The rate of schools that used only stethoscope, tongue pressor as the medical instruments reaches 53.4% and 87.1% of elementary & secondary school give the invited doctors the allowance a nurse teachers conference decided. The number of 8.9% schools pay the doctors independent allowance. The medical examomatopm allowance is 200 to 250 won per capita. The rate is 56.1%. Forth, after the medical examination 72.1% of school sends letter to the parents to notice the result of the examination. The number of response from parent is 12.5%. The observation record in secondary school is 70.6% for junior, and 80.0% for senior respectively, and 65.5% is for the elementary school children. To conclude the regular physical examination in elementary & secondary school is very important. Because the students are in the stage of rapid growth and development. Early finding of the students diseases can help to cure with ease. In the light of public health the management of health program in the elementary & secondary school is of consequence.

  • PDF

경질형 폴리우레아로 보강된 RC 슬래브의 성능 평가 (Performance Evaluation of RC Slabs Strengthened by Stiff Type PolyUrea)

  • 박정천;이상원;김성배;김장호
    • 대한토목학회논문집
    • /
    • 제31권6A호
    • /
    • pp.457-464
    • /
    • 2011
  • 본 연구에서는 경질형 폴리우레아로 보강된 RC 슬래브의 보강성능과 파괴거동을 파악하기 위한 실험적 연구를 수행하였다. 보강성능을 평가하기 위해 경질형 폴리우레아를 도포한 시험체와 기존의 보강재로 사용되는 탄소섬유시트와 유리섬유시트를 부착한 시험체, 무보강 시험체를 제작하여 실험을 수행하였으며, 구조물의 보강성능에 큰 영향을 미치는 부착성능 평가도 수행하였다. 휨 성능 평가결과로는 경질형 폴리우레아를 도포한 시험체는 무보강 시험체보다 높은 휨 성능을 보였지만 섬유시트를 부착한 시험체보다는 다소 낮은 휨 성능을 나타내었다. 하지만 경질형 폴리우레아를 도포한 시험체는 탄성범위를 넘어선 소성구간에서의 연성거동은 우수한 것으로 나타났다. 부착성능 결과에서는 모든 시험체의 부착성능이 표준부착 강도인 1.5 MPa 이상의 값으로 높게 나타났다. 또한, 경질형 폴리우레아를 도포한 시험체는 섬유시트의 보강방법에 사용되는 에폭시 레진을 사용하지 않아도 인장용 지그와 경질형 폴리우레아의 탈락이 일어나지 않고 콘크리트 모재와의 탈락이 발생한 것으로 나타나 경질형 폴리우레아를 콘크리트의 보강재로 사용 할 경우 부착성능의 저하로 인한 보강효과의 성능저하는 일어나지 않을 것으로 확인되었다.

성능향상된 교량 바닥판의 확률론적 해석 및 수명연장 분석 (Analysis of Probability and Extended Life Cycle of Strengthened Bridge Deck)

  • 심종성;오홍섭;최장환;김언경
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.635-642
    • /
    • 2003
  • 최근들어 노후화된 교량의 증가에 따라 바닥판의 보강효과에 대한 많은 연구가 이루어지고 있으나 대부분의 연구는 실험실 수준에 국한되어 있으며, 구조물의 피로거동은 이동하중이 아닌 고정반복하중에 의한 연구가 집중적으로 시행되고 있다. 본 연구에서는 이동하중의 영향을 반영하기 위하여 국내에서 실측된 축하중으로 활하중 모델을 제시하였다. 확률론적 해석과 신뢰성 해석을 적용하여 탄소섬유쉬트와 격자형 탄소섬유로 성능향상된 바닥판의 보강효과 및 연장수명을 예측한 결과 성능향상 된 설계 2등급의 교량바닥판은 일반적인 증가 차량하중에 대하여 사용기간동안 충분한 내하력뿐만 아니라 충분한 피로거항성을 갖는 것으로 나타났다.

저수조의 효율적 관리를 위한 수질실태에 관한 연구 (A Study on the Water Quality for Efficient Management in the Water Tanks)

  • 박현건;류승철;전수임
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1339-1347
    • /
    • 2009
  • This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.

유리섬유보강재로 외부부착 보강된 교량 바닥판의 구조거동 (Structural Behavior on the Externally Strengthened Bridge Deck with Glass Fiber Reinforced Polymer)

  • 오홍섭;심종성;최장환
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.922-933
    • /
    • 2002
  • 교량바닥판의 손상이 구조물의 내구성, 안전성 및 기능에 영향을 미치기 때문에 손상된 바닥판의 성능향상을 위하여 섬유보강재를 사용한 구조물보강 사례가 증가하고 있다. 그러나 최근의 연구들이 구조물의 정적거동에 국한되어 있는 상이며, 피로거동에 대한 연구는 극히 제한적으로 수행되고 있다. 본 연구에서는 쉬트형 유리섬유보강재로 보강된 11개의 바닥판시험체에 대하여 정적 및 피로실험을 실시하여 구조거동을 실험적으로 검증하고자 하였다. 정적실험변수는 보강방향에 따른 보강량을 변수로 하였으며, 정적시험결과로부터 나타난 무보강시험체와 보강시험체의 최대하중에 기초하여 피로시험시의 응력수준을 선정하였다. 시험결과 보강된 바닥판의 경우 균열진전에 대한 저항성이 증진되는 것으로 나타났으며, 응력분배 효과 또한 뛰어난 것으로 나타났다. 이와 함께 피로시험결과 컴플라이언스 변화정도 역시 무보강바닥판에 비하여 효과적으로 감소하는 것으로 나타났다.