Strengthening Efficiency for the Various Corner Shapes of RC Member confined with Continuous Fiber Sheets (연속섬유 시트로 보강된 RC 부재의 모서리 형상에 따른 보강 효율에 관한 연구)

  • Ko, Hune-Bum;Lee, Jin-Seop
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • Recently, fiber reinforced polymers(FRP) composite materials are used extensively in the rehabilitation of concrete structural members. A main application is to wrap beams and columns using the continuous fibers sheets to improve their strength and ductility. The corner chamfering affects significantly the performance of the continuous fibers sheets, and could lead to environmental problem with waste and dust. The main purpose of this paper is to verify the effect of corner conditions on the strength of the continuous fiber sheets, and to introduce new attached components which can avoid environmental problem. A total of 15 specimens were tested and carefully checked for three types of continuous fiber sheets(carbon, glass, and aramid) and three types of corner conditions(non-chamfering, chamfering, and device attaching). It is proved that the devices proposed in this research have some capabilities to use for RC member. But additional research will be needed for commercializing.

Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils (3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

Adhesion Characteristic and Porosity Change of Alkali Silicate Impregnant of Concrete (Silicate계 콘크리트 함침제 도포에 따른 부착특성 및 공극변화)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Lim, Young-Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.4
    • /
    • pp.276-282
    • /
    • 2010
  • There are the impregnating layer formation by surface protective materials or impregnants and the adhesion method by polymer, FRP sheet or steel plate in the surface protective method of concrete structure. The surface impregnation method by impregnants improves the durability of concrete structure by modifying the structure of the concrete surface and also have a merit that can be shortly applied in place without the decrease of concrete surface appearance and is easily applied again. This study is interested in manufacturing the concrete surface impregnants including lithium and potassium silicate for the repair of the exposed concrete and the color concrete requiring the advanced function in view of the concrete appearance. The durability and porosity properties was tested for the review of application. The result of this study show that the effective content of silicate ranges 5 to 20% and the separate application of the first impregnant and the second impregnant is effective for the optimum performance. The adhesion in tension is slightly increased but the reinforcement of concrete substrate is slight. So, the concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

Numerical Analysis of Fracture Behavior in Aged RC Structures (보강된 노후 구조물 파괴거동 예측을 위한 수치해석기법 개발)

  • 신승교;고태호;김문겸;임윤묵
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1031-1036
    • /
    • 2000
  • In this study, a numerical simulation that can effectively predict the strengthening effect of repaired aged RC structures is developed using the axial deformation link elements. In repaired structures, concrete and interface are modeled as quasi-brittle materials. An elastic-perfectly plastic constitutive relationship is introduced for reinforcing bars. Also, a linear-elastic relationship for repair materials such as FRP or CFS. Structural deterioration in terms of corrosion of steel rebar is considered. The interfacial property between steel and concrete which is reduced by corrosion of steel rebar is obtained by comparing numerical results with experimental results of pull out tests. Obtained values are used in repaired reinforced concrete structures under flexural loading conditions. To investigate strengthening effect of the structures repaired with carbon fiber sheet(CFS), repaired and unrepaired RC structures are analyzed numerically. From analysis, rip-off, debonding and rupture failure mechanisms of interface between substrate and CFS can be determined. Finally, strengthening effect according to the variation of interfacial material properties is investigated, and it is shown that interfacial material properties have influence on the mechanical behavior of repaired structure systems Therefore, the developed numerical method using axial deformation link elements can use for determining the strengthening effects and failure mechanism of repaired aged RC structure.

Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss (탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성)

  • Seo, Soo-Yeon;Yun, Hyun-Do;Choi, Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.795-802
    • /
    • 2007
  • Recently, various strengthening methods using carbon fiber sheets (CFS) have been developed for the rehabilitation of structures and applied to the concrete member. However, still research need arises in order to verify the structural capacity of RC member which experienced bond loss between concrete and CFS after strengthening. This is because previous research has focused on the development of design process and evaluation of structural capacity only for retrofit. The appearance of this loss may be initiated at just after retrofit construction. And it will be more serious when the layer number of CFS increases. In order to minimize above mistake in retrofit design using CFS, more exact evaluation process to predict the bond loss of CFS is required. The objective of this research is to study the variation of flexural structural capacity of beam which has experienced bond loss after strengthening using CFS. Experimental and analytical study are performed and evaluation of the previous formula is conducted. Test result showed that the significant strength deterioration was not found until the bond loss of 20%. Overall structural behavior of the beams can be predicted by nonlinear sectional analysis.

The Analysis of the Physical Examination of Elementary & Secondary School Students -Centering on the Primary Health Assessment- (초(初)·중(中)·고등학생(高等學生)의 체질검사(體質檢査) 실태분석(實態分析) - 1차(次) 건강사정(健康査定)을 중심(中心)으로-)

  • Lee, Kang Soon;Chung, Yeon Kang;Park, Keoi Sug
    • Journal of the Korean Society of School Health
    • /
    • v.7 no.1
    • /
    • pp.9-28
    • /
    • 1994
  • This study is to investigate the status and problems in the anual physical examination in elementary & secondary schools. The study helps the introduction of health assessment. Two hundreds and forty nurse teachers of elementary & seconcary school in Seoul received in-service traomong fpr 20 daus frp, September 7 to September 27, 1992. Questionnaires were given to the 240 teachers and the number of collected questionnaire is 112. The result of the questionnaire analysis is like the following. First, the answered teachers aged 35~39, 36.6%; experience 6~10 years 37.5%; the number of class 31~40, 28.6%. Among the answered of the school doctors is practicioners. The doctors major subjects are 26.8% of internal medicine and 35.7% of surgery. Second, in elementary & secondary school nurse teachers received in-service training for the primary health assessment. And then 37.5% of schools practiced the health assessment. The term of the health assessment is largely a-year-length, occurately its rate of schools have practiced the assessment reaches 81.0%. The number of health assessment are consist of eyes, nose, ear, throat, skin, spine, heart and other abnormal regions and diseases all over the body. And 83.3% of the rate of the health assessment includes all these contents. The period of the health assessment is 7 to 28 days. Third, the physical examination conducted by school doctors is 91.0%. The method is various; one is 56.6% of the students who checked first by he nurse teacher. The number of 15.1% of the schools is directly checked by the school doctor. The invited medical doctors are divided into two categories. The number of general physician is 61.9%. Contrary to that school doctors are 38.1%. The contents of the medical examination is all the items printed on the medical examination sheet. To follow the medical examination sheet the number of school is 59.6%. Eyes, throat, skin and heart etc. partly medical examination is 40.4%. The rate of schools that used only stethoscope, tongue pressor as the medical instruments reaches 53.4% and 87.1% of elementary & secondary school give the invited doctors the allowance a nurse teachers conference decided. The number of 8.9% schools pay the doctors independent allowance. The medical examomatopm allowance is 200 to 250 won per capita. The rate is 56.1%. Forth, after the medical examination 72.1% of school sends letter to the parents to notice the result of the examination. The number of response from parent is 12.5%. The observation record in secondary school is 70.6% for junior, and 80.0% for senior respectively, and 65.5% is for the elementary school children. To conclude the regular physical examination in elementary & secondary school is very important. Because the students are in the stage of rapid growth and development. Early finding of the students diseases can help to cure with ease. In the light of public health the management of health program in the elementary & secondary school is of consequence.

  • PDF

Performance Evaluation of RC Slabs Strengthened by Stiff Type PolyUrea (경질형 폴리우레아로 보강된 RC 슬래브의 성능 평가)

  • Park, Jeong Cheon;Lee, Sang Won;Kim, Sung Bae;Kim, Jang-Ho Jay
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6A
    • /
    • pp.457-464
    • /
    • 2011
  • An experimental study was performed to evaluate the possibility of using stiff type PolyUrea(PU) on RC slab as a strengthening material. Stiff type PU(STPU) was sprayed on the bottom surface of the slab specimens, which were then attached with CFRP or GFRP sheets. Also the evaluation of the bond capacity, the single most influential parameter on strengthening of RC structures, was carried out the flexural capacity evaluation test results showed that the load carrying capacity of the PU specimen was greater and less than the unstrengthened and FRP sheet attached specimens, respectively. The STPU specimens showed a ductile flexural behavior in the plastic displacement range. With respect to bond capacity, the bond strength of all of the specimen exceeded the code required bond strength of 1.5 MPa. Also, the STPU sprayed specimen without using epoxy resin did not peel off when the tensile grip was applied for testing. The stability of the PU bond failure indicate a good bond strength of PU when applied to concrete.

Analysis of Probability and Extended Life Cycle of Strengthened Bridge Deck (성능향상된 교량 바닥판의 확률론적 해석 및 수명연장 분석)

  • Sim, Jong-Sung;Oh, Hong-Seob;Choi, Jang-Whan;Kim, Eon-Kyoung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.635-642
    • /
    • 2003
  • Although the strengthening effect of deteriorated concrete bridge decks has been studied by various authors, most researches are focused on the experimental works on the pulsating loading in laboratory in spite of deterioration of deck caused by moving vehicle loads. In this research, a theoretical live load model that was proposed to reflect an effect of moving vehicle loads is formulated from a statistical approach on the measurement of real traffic loads for various time periodsin Korea. Fatigue life and strengthening effect of strengthened bridge decks strengthened with either Carbon Fiber Sheet or Grid typed Carbon Fiber Polymer Plastic by the probabilistic and the reliability analyses are assessed. As a results, secondary bridge deck (DB18) strengthened with FRP ensures a sufficient fatigue resistance against the increased traffic loads as well as load carrying capacity in life cycle.

A Study on the Water Quality for Efficient Management in the Water Tanks (저수조의 효율적 관리를 위한 수질실태에 관한 연구)

  • Park, Hyun-Geoun;Ryu, Seung-Chul;Jun, Soo-Im
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1339-1347
    • /
    • 2009
  • This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.

Structural Behavior on the Externally Strengthened Bridge Deck with Glass Fiber Reinforced Polymer (유리섬유보강재로 외부부착 보강된 교량 바닥판의 구조거동)

  • 오홍섭;심종성;최장환
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.922-933
    • /
    • 2002
  • Since the deterioration of concrete bridge decks affect durability, safety, and function, structural rehabilitation of damaged concrete deck that was strengthened with Fiber Reinforced Polymer(FRP) is increasing the latest. But recent studies on the strengthened structures are focused on the static behavior, however only a few studies on the fatigue behavior are performed. In this study, static and fatigue behavior of strengthened deck were peformed on 11 deck specimens strengthened with sheet typed Glass Fiber Reinforced Polymer(GFRP) that were reinforced by two different strengthening methods for the static test. A amount of strengthening material in the each direction such as transverse and longitudinal was adopted experimental variables for the static test and also the stress level of the static maximum load are adopted for the fatigue test. By the results of the experimental study, with respect to the strengthened decks, the resistance effect of crack propagation and effect of stress distribution are improved. In addition, the rate of variation of compliance decreased.