• Title/Summary/Keyword: FRP rebar

Search Result 68, Processing Time 0.023 seconds

Flexural Behavior of Concrete Beams Reinforced with CFRP rebars (CFRP Rebar로 보강한 콘크리트 보의 휨 거동)

  • Lee, Young-Hak;Won, Dong-Min;Kim, Min-Sook;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • To address the problems caused by the corrosion of steel rebar, active research has recently been carried out on members where fiber-reinforced polymer (FRP) is used in place of rebar. As FRP bar is highly brittle and has a low modulus of elasticity, further research is needed on the evaluation of serviceability, in other words on the deflection of flexural concrete members reinforced with FRP rebars. Taking the reinforcement ratio as a variable, this paper analyzes the flexural capacity of concrete beams reinforced with CFRP rebar. The test results of specimens reinforced with CFRP rebar show an increase in stiffness and resisting force along with an increase in the reinforcement ratio. A reinforcement ratio of about 1.3 is needed for the member reinforced with CFRP rebar to show same section property of a steel member. Through a comparison for the value of an effective moment of inertia, the equation suggested by Bischoff & Scanlon predicted values closest to the actual results.

New Suggestion of Effective Moment of Inertia for Beams Reinforced with the Deformed GFRP Rebar (이형 GFRP Rebar로 보강된 보의 유효단면이차모멘트 산정식 제안)

  • Sim, Jong-Sung;Oh, Hong-Seob;Ju, Min-Kwan;Lim, Jun-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.185-191
    • /
    • 2008
  • To fundamentally solve the problem of deterioration of concrete structures, it has been researched that the high durable concrete structure reinforced with the FRP rebar can be one of major solution to the newly-developed concrete structure. FRP rebar has lots of advantages such as non-corrosive, high performance and light weight against the conventional steel rebar. Among these kinds of FRP rebars, GFRP rebar has usually been considered as the best reinforcement because of its economic point of view. Even though the material capacity of the GFRP rebar was already investigated, there are some problems such as low modulus of elastic that will be cause for degrade of the serviceability of flexural concrete member reinforced with the GFRP rebar. Thus, the deflection characteristics of the GFRP rebar reinforced concrete structure should be considered then investigated. In this study, ACI 440 guideline (2003), ISIS Canada Design Manual (2001) and Toutanji et al. (2000) was considered for predicting the moment of inertia of the concrete beam reinforced with the GFRP rebar. And it was also evaluated that load-deflection relationship had a good accordance with the test and analysis result. In the result of this study, it could be estimated that the load-deflection relationship using the suggested equation of moment of inertia in this study indicated better accordance with the test result than that of the others until failure.

Flexural Behavior of High-strength Concrete Beam Reinforced with AFRP rebar (AFRP rebar로 보강된 고강도 콘크리트 보의 휨 거동)

  • Won, Dong-Min;Joe, Jang-Se;Lee, Young-Hak;Kim, Hee-Cheul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.323-326
    • /
    • 2009
  • 콘크리트의 보강재로 높은 인장 강도와 비부식성, 비자기성, 비전기성 등의 장점을 갖는 FRP의 사용에 대한 연구가 활발히 진행되고 있다. 하지만 FRP가 갖는 낮은 탄성계수와 취성적 성질로 인해 기존 설계방법을 적용하기에는 문제가 있다. 본 연구에서는 보강비 변화에 따른 AFRP 보강 콘크리트 보의 구조 실험을 수행하여 FRP 보강근을 사용한 콘크리트 부재의 휨 성능 연구에 대한 기초적 자료를 제공하고자 하였다. 각 실험체의 결과 데이터를 비교 분석한 결과 균형보강비를 기준으로 저보강 실험체는 FRP의 파단에 의해 급격한 파괴양상을 보인 반면에, 과보강 실험체는 콘크리트가 압괴하는 파괴 징후를 보이며 파괴에 도달하였다. FRP 보강근을 사용한 보 부재의 설계에 균형보강 이상의 설계가 요구되며, 과보강의 경우 고강도 콘크리트의 사용이 요구되는 것으로 분석되었다.

  • PDF

Experimental Study on GFRP Reinforcing Bars with Hollow Section (중공형 GFRP 보강근의 인장성능 실험연구)

  • You, Young-Jun;Park, Ki-Tae;Seo, Dong-Woo;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Fiber-reinforced polymer (FRP) has been generally accepted by civil engineers as an alternative for steel reinforcing bars (rebar) due to its advantageous specific tensile strength and non-corrosiveness. Even though some glass fiber reinforced polymer (GFRP) rebars are available on a market, GFRP is still somewhat uncompetitive over steel rebar due to their high cost and relatively low elastic modulus, and brittle failure characteristic. If the price of component materials of GFRP rebar is not reduced, it would be another solution to increase the performance of each material to the highest degree. The tensile strength generally decreases with increasing diameter of FRP rebar. One of the reasons is that only fibers except for fibers in center resist the external force due to the lack of force transfer and the deformation of only outer fibers by gripping system. Eliminating fibers in the center, which do not play an aimed role fully, are helpful to reduce the price and finally FRP rebar would be optimized over the price. In this study, the effect of the hollow section in a cross-section of a GFRP rebar was investigated. A GFRP rebar with 19 mm diameter was selected and an analysis was performed for the tensile test results. Parameter was the ratio of hollow section over solid cross-section. Four kinds of hollow sections were planned. A total of 27 specimens, six specimens for each hollow section and three specimens with a solid cross-section were manufactured and tested. The change by the ratio of hollow section over solid cross-section was analyzed and an optimized cross-section design was proposed.

Analytical study on the Bond Behavior of FRP Rebar in Concrete (FRP Rebar의 부착거동 해석)

  • You Young-Jun;Park Young-Hwan;Park Ji-Sun;You Young-Chan;Kim Hyeong-Yeol;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.636-639
    • /
    • 2004
  • Reinforced concrete structures have been used for a long time. However, corrosion problem in reinforcing steel is inevitable, which results in the degradation of performance and the shortening of the life of structures. To overcome such problems, FRP(Fiber Reinforced Polymer) rebars have been developed. Due to their corrosion resistance and their superior mechanical properties, FRP rebars are increasingly applied to concrete structures in other countries. To obtain the composite action between FRP rebars and concrete, sufficient bond between two materials must be secured. But, the behavior of FRP rebars is different from that of steel rebars. Therefore, it is necessary to understand and develop the proper bond mechanism of FRP rebars to use them in concrete structures. This paper presents analytical results to investigate the bond-slip relationship between FRP rebars and concrete based on pull out tests.

  • PDF

Ductile Effect of Hybrid Fiber Reinforced Composite Rebar (하이브리드 섬유강화 복합재료 리바의 연성효과)

  • Choi, Myung-Sun;Han, Gil-Young;Lee, Dong-Gi;Ahn, Dong-Gue
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.112-116
    • /
    • 2003
  • This paper describes the need for a ductile of Fiber Reinforced Plastic(FRP) reinforcement for concrete structures. The criteria to be met by the FRP, which are based on the properties of the steel rebar it is to replace, are threefold: high initial modulus, a definite yield point and a high level of ultimate strain. It is shown that the use of a fiber architecture based design methodology facilitates the optimization of the performance of FRP through material and geometric hybrid. Ductile hybrid FRP bars were successfully fabricated at 3mm and 5mm nominal diameters using an in-line braiding and pultrusion process.

  • PDF

Effect of Acceterated Aging on the Tensile and Bond Properties of FRP Rebar for Concrete (콘크리트 보강용 FRP 리바의 촉진환경 노출후 인장 및 부착 특성)

  • Park, Chan-Gi;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.73-84
    • /
    • 2005
  • The main objective was to evaluate the tensile and bond properties of FRP rebar and durability performance after exposure of accelerated aging condition. Five types of FRP rebar include CFRP ISO, GFRP Asian, AFRP Technora, CFRP(D) and GFRP(D) rebars used in tensile and bond tests. Tensile test results of CFRP(D) and GFRP(D) were shown to possess acceptable tensile and durability performance compared with CFRP ISO, GFRP Asian, and AFRP Technora, Also, bond test results indicated that CFRP(D) and GFRP(D) rebars showed an ability to improve the bond strength.

Parametric Study on Design Variables of Concrete Beam Reinforced with GFRP Rebar using Finite Element Analysis (유한요소해석에 의한 GFRP 보강 콘크리트 보의 설계인자 분석)

  • Moon, Do-Young;Oh, Hong-Seob;Ahn, Kwang-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.357-367
    • /
    • 2008
  • Parametric study of beams with reinforced with FRP rebar is conducted in this study. Using ABAQUS program, the finite element analysis model is set and calibrated with the experimental results which have been conducted by the authors. The employed design parameters are reinforcement ratio, elastic modulus of rebar, and concrete strength. The obtained results from FE analysis are investigated in terms of normalized beam stiffness. In particular, the effect of reinforcement ratio on the flexural stiffness is investigated with comparing with the model code specified on ACI 440. From the analysis results, the reinforcement ratio in beam is the first parameter affecting on the beam stiffness. In addition, its effect could be increased with higher concrete strength.

Analysis of Failure Behavior of FRP Rebar Reinforced Concrete Slab based on FRP Reinforced Ratio (FRP 보강근비에 따른 FRP 보강 콘크리트 슬래브의 파괴거동 분석)

  • Jang, Nag-Seop;Kim, Young-Hwan;Oh, Hong-Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.173-181
    • /
    • 2021
  • Reinforced concrete structures are exposed to various environments, resulting in reinforcement corrosion due to moisture and ions penetration. Reinforced concrete corrosion causes a decrease in the durability performance of reinforced concrete structures. One solution to mitigate such issues is using FRP rebars, which offer several advantages such as high tensile strength, corrosion resistance, and light-weight than conventional rebars, in reinforced concrete instead of conventional steel rebars. The FRP rebar used should be examined at the limit state because FRP reinforced concrete has linear behavior until its fracture and can generate excessive deflection due to the low elastic modulus. It should be considered while designing FRP reinforced concrete for flexure. In the ultimate limit state, the flexural strength of FRP reinforced concrete as per ACI 440.1R is significantly lower than the flexural strength by applying both the environmental reduction and strength reduction factors accounting for the material uncertainty of FRP rebar. Therefore, in this study, the experimental results were compared with the deflection of the proposed effective moment of inertia referring to the local and international standards. The experimental results of GFRP and BFRP reinforced concrete were compared with the flexural strength as determined by ACI 440.1R and Fib bulletin 40. The flexural strength obtained by the experimental results was more similar to that obtained by Fib bulletin 40 than ACI 440.1R. The flexural strength of ACI 440.1R was conservatively evaluated in the tension-controlled section.

Characteristics of Kevlar-Glass fiber reinforced plastic for Concrete Structure by the Braidtrusion process (브레이드 투루젼법에 의한 콘크리트 구조물용 케블라-유리섬유 강화 복합재료 리바 특성)

  • 최명선;곽상묵;배시연;이동기;심재기;한길영
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.48-52
    • /
    • 2002
  • This paper describes the need for a ductile Fiber Reinforced Plastic(FRP) reinforcement for Concrete Structures. Using the material hybrid and geometric hybrid, it is demonstrated that the pseudo-ductility Characteristic can be generated in FRP rebar. Ductile hybrid FRP bars were successfully fabricated at Ø3mm and Ø10mm nominal diameters using the braidtrusion process. Tensile and bending specimens from these bars were tested and compared with behavior of stress-strain of steel bar and GFRP rebar

  • PDF