• 제목/요약/키워드: FRP concrete

검색결과 751건 처리시간 0.105초

Low strength concrete members externally confined with FRP sheets

  • Ilki, Alper;Kumbasar, Nahit;Koc, Volkan
    • Structural Engineering and Mechanics
    • /
    • 제18권2호
    • /
    • pp.167-194
    • /
    • 2004
  • In this paper axial loading tests on low strength concrete members, which were confined with various thickness of carbon fiber reinforced polymer (CFRP) composite sheets are described. Totally 46 specimens with circular, square and rectangular cross-sections with unconfined concrete compressive strengths between 6 and 10 MPa were included in the test program. During the tests, a photogrammetrical deformation measurement technique was also used, as well as conventional measurement techniques. The contribution of external confinement with CFRP composite sheets to the compressive behavior of the specimens with low strength concrete is evaluated quantitatively, in terms of strength, longitudinal and lateral deformability and energy dissipation. The effects of width/depth ratios and the corner radius of the specimens with rectangular cross-section on the axial behavior were also examined. It was seen that the effectiveness of the external confinement with CFRP composite sheets is much more pronounced, when the unconfined concrete compressive strength is relatively lower. It was also found that the available analytical expressions proposed for normal or high strength concrete confined by CFRP sheets could not predict the strength and deformability of CFRP confined low strength concrete accurately. New expressions are proposed for the compressive strength and the ultimate axial strain of CFRP confined low strength concrete.

Analytical and numerical studies on hollow core slabs strengthened with hybrid FRP and overlay techniques

  • Kankeri, Pradeep;Prakash, S. Suriya;Pachalla, Sameer Kumar Sarma
    • Structural Engineering and Mechanics
    • /
    • 제65권5호
    • /
    • pp.535-546
    • /
    • 2018
  • The objective of this study is to understand the behaviour of hollow core slabs strengthened with FRP and hybrid techniques through numerical and analytical studies. Different strengthening techniques considered in this study are (i) External Bonding (EB) of Carbon Fiber Reinforced Polymer (CFRP) laminates, (ii) Near Surface Mounting (NSM) of CFRP laminates, (iii) Bonded Overlay (BO) using concrete layer, and (iv) hybrid strengthening which is a combination of bonded overlay and NSM or EB. In the numerical studies, three-dimensional Finite Element (FE) models of hollow core slabs were developed considering material and geometrical nonlinearities, and a phased nonlinear analysis was carried out. The analytical calculations were carried out using Response-2000 program which is based on Modified Compression Field Theory (MCFT). Both the numerical and analytical models predicted the behaviour in agreement with experimental results. Parametric studies indicated that increase in the bonded overlay thickness increases the peak load capacity without reducing the displacement ductility. The increase in FRP strengthening ratio increased the capacity but reduced the displacement ductility. The hybrid strengthening technique was found to increase the capacity of the hollow core slabs by more than 100% without compromise in ductility when compared to their individual strengthening schemes.

AFRP로 보강된 철근콘크리트 보의 휨 거동과 연성도 평가 (Evaluation of Behavior and Ductility of Reinforced Concrete Beams Strengthened With AFRP)

  • 김준원;김태완;홍성남;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.206-214
    • /
    • 2009
  • FRP는 재료가 가지고 있는 특성 때문에 최근 들어 미국, 일본 등에서 보강 재료로 널리 쓰이고 있으며 우리나라에서도 활발한 연구가 이루어지고 있다. 본 연구에서는 EBR, NSMR 보강공법을 사용하는 동시에 AFRP의 종류와 보강면적을 다르게 보강하여 각 실험체의 거동과 연성을 평가하였다. 보강면적을 증가시킨 경우가장 큰 하중증가를 보였으나 취성적인 파괴 양상을 띠었으며 미성숙파괴가 일어났다. 공법면에서는 NSMR공법으로 보강하는 것이 더 효율적인 것으로 나타났으며 보강재료 표면의 요철이 연성파괴를 유도하는 것으로 나타났다.

GFRP 근 보강 콘크리트 교량 바닥판의 설계지배인자 (Governing Design Factors of GFRP-Reinforced Concrete Bridge Deck)

  • 조정래;박영환;박성용;조근희;김성태
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.70-77
    • /
    • 2015
  • In this study, the governing design factors of GFRP-reinforced concrete bridge deck are analyzed for typical bridges in Korea. The adopted bridge deck is a cast-in-situ concrete bridge deck for the prestressed concrete girder bridge with dimensions of 240 mm thickness and 2.75 m span length from center-to-center of supporting girders. The selected design variables are the diameters of GFRP rebar, spacings of GFRP rebars and concrete cover thicknesses, Considering the absence of the specification relating GFRP rebar in Korea, AASHTO specification is used to design the GFRP-reinforced concrete bridge deck. The GFRP-reinforced concrete bridge deck is proved to be governed by the criteria about serviceability, especially maximum crack width, while steel reinforced concrete bridge deck is governed by the criteria on ultimate limit state. In addition, GFRP rebars with diameter of 16 mm ~ 19 mm should be used for the main transverse direction of decks to assure appropriate rebar spacings.

해양에 위치한 고속도로교량에 대한 내염보수 공법(2)-전기방식시공결과 (Repair of Highway Bridge damaged by Chloride Attack in Marine Environment(2) - Application of Cathodic Protection)

  • 지한상;한복규;정해문;안태송;류종현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.786-789
    • /
    • 2004
  • Corrosion of reinforced concrete structures in marine environment is one of the most important mechanism of deterioration. However, conventional rehabilitation techniques in tidal zone, which consist of removing delaminated areas of concrete, cleaning affected steel and patching with portland cements mortar, have proven to be ineffective for marine structures. Also, repairs are often repeated every several years. The purpose of this report is to announce appropriate repair method of highway bridge damaged by chloride attack in marine environment (application of cathodic protection) using FRP and antiwashout underwater mortar.

  • PDF

강섬유를 보강한 강상판 합성보의 거동에 관한 기초적 연구 (Fundamental Study of Behavior on Steel·Concrete Composite Beam Reinforced Steel Fiber)

  • 서성탁
    • 한국산업융합학회 논문집
    • /
    • 제11권2호
    • /
    • pp.93-98
    • /
    • 2008
  • Steel fibre reinforced concrete (SFRC) were considered a new technology for the construction industry. However today this technology has found wider acceptance among the construction industry. Currently, steel fibres are used in varied segments in many application areas across different segments in the construction industry, especially in tunneling, airports, warehouses, etc. Time and safety are the main factors are among the various advantages which renders steel fibres superior to the competing product. For fibers reinforcing, The maximum load carrying capacity is controlled by fibers pulling out of the composite because fiber reinforcing does not have a deformed surface like larger steel reinforcing bars. The study demonstrated that above concept is applicable and effective in concrete structure by analytical study. The analytical result appears that SFRP have the potential to significantly increase the strength of existing concrete structures, while at the same time dramatically improving their fracture energy characteristics.

  • PDF

Steel-CFRP composite and their shear response as vertical stirrup in beams

  • Uriayer, Faris A.;Alam, Mehtab
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1145-1160
    • /
    • 2015
  • An experimental study was conducted for the effectiveness of steel-CFRP composite (CFRP laminates sandwiched between two steel strips) as stirrups in concrete beam to carry shearing force and comparison was made with conventional steel bar stirrups. A total numbers of 8 concrete beams were tested under four point loads. Each beam measured 1,600 mm long, 160 mm width and 240 mm depth. The beams were composed of same grade of concrete, with same amount of flexural steel but different shear reinforcements. The main variables include, type of stirrups (shape of stirrups and number of CFRP layers used in each stirrup) and number of stirrups used in shear spans. After getting on an excellent closeness between the values of ultimate shear resistance and ultimate tensile load of steel-CFRP stirrups, it could be concluded that the steel-CFRP stirrups represent the effective solution of premature failure of FRP stirrups at the bends.

A numerical study on behavior of CFRP strengthened shear wall with opening

  • Behfarnia, Kiachehr;Shirneshan, Ahmadreza
    • Computers and Concrete
    • /
    • 제19권2호
    • /
    • pp.179-189
    • /
    • 2017
  • Concrete shear walls are one of the major structural lateral resisting systems in buildings. In some cases, due to the change in the occupancy of the structure or functional requirements like architectural and even mechanical ones, openings need to be provided and installed in structural walls after their construction. Providing these openings may significantly influence the structural behavior of the constructed wall. This paper considers the results of a nonlinear finite element analysis of shear walls with opening strengthened by carbon fiber reinforced polymer (CFRP) strips with different configurations. Details of bond-slip constitutive model of link elements to simulate the connections of FRP strips to concrete surface is presented. The proposed model in this research has been validated using experimental results available in the literature. The results indicated that the proposed configuration of CFRP strips significantly improved the lateral resistance and deformation capacity of the shear walls with opening.

Strengthening of axially loaded concrete columns using stainless steel wire mesh (SSWM)-numerical investigations

  • Kumar, Varinder;Patel, P.V.
    • Structural Engineering and Mechanics
    • /
    • 제60권6호
    • /
    • pp.979-999
    • /
    • 2016
  • Stainless steel wire mesh (SSWM) is an alternative material for strengthening of structural elements similar to fiber reinforced polymer (FRP). Finite element (FE) method based Numerical investigation for evaluation of axial strength of SSWM strengthened plain cement concrete (PCC) and reinforced cement concrete (RCC) columns is presented in this paper. PCC columns of 200 mm diameter with height 400 mm, 800 mm and 1200 mm and RCC columns of diameter 200 mm with height of 1200 mm with different number of SSWM wraps are considered for study. The effect of concrete grade, height of column and number of wraps on axial strength is studied using finite element based software ABAQUS. The results of numerical simulation are compared with experimental study and design guidelines specified by ACI 440.2R-08 and CNR-DT 200/2004. As per numerical analysis, an increase in axial capacity of 15.69% to 153.95% and 52.39% to 109.06% is observed for PCC and RCC columns respectively with different number of SSWM wraps.

조립식 쏘일네일링 공법의 개발과 시험시공사례에 관한 연구 (A Study on the Development of Assembling Soil Nailing Method and Its Applications)

  • 권영호;박신영;류정수;강인규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.113-120
    • /
    • 2005
  • Soil nailing system can be mentioned to a method of supporting as the shear strength of in-situ soils is increased by passive inclusions. In the general soil nailing system, facing walls are used in two kind of a lattice concrete block or a cast in placed concrete wall. A case of lattice concrete blocks is used in slow slopes greater than 1:0.7. Also, a case of a cast in placed concrete wall is used in steep slopes less than 1:0.5. The cast in placed concrete walls are constructed to 30cm thick together with a shotcrete facing. In this study, the assembling soil nailing method as a new soil nailing system is proposed. This method is constructed assembly using precast concrete panels. Therefore ability of the construction and quality of the facings can be modified than a usual soil nailing system. Also, this method can be obtained the effects that a global slope stability increase, as precast concrete panels is put on cutting face after excavating a slope.

  • PDF