• Title/Summary/Keyword: FRP RC

Search Result 287, Processing Time 0.019 seconds

Experimental Study on Flexural Behavior of RC Slab Strengthened by FRP Sheet and GSP (FRP 쉬트 및 GSP로 보강된 RC 슬래브의 휨거동에 관한 실험적 연구)

  • Ahn, Ki-Man;Kim, Kwang-Soo;Kim, Tae-Wan;Park, Sun-Kyu;Lee, Young-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.185-188
    • /
    • 2006
  • Recently, an improved capacity for RC bridges is required by their deterioration or necessary to carry traffic increase. Strengthening is known as a better way to improve capacity of bridges than reconstructing. Fiber Reinforced Plastics (FRP) is introduced as one of the best strengthening structures in this paper. It is also known as an economical improvement. Therefore, FRP sheet and Glass Fiber-Steel Composite Plate (GSP) in this research were used in strengthening slab of RC bridges. Experimental data from the strengthening will be helpful to better understand the slab behavior and an effect of the strengthening.

  • PDF

Analysis of behavior of bare and in-filled RC frames subjected to quasi static loading

  • Sandhu, Balvir;Sharma, Shruti;Kwatra, Naveen
    • Structural Engineering and Mechanics
    • /
    • v.73 no.4
    • /
    • pp.381-395
    • /
    • 2020
  • Study on the inelastic response of bare and masonry infilled Reinforced Concrete (RC) frames repaired using Carbon Fibre Reinforced Polymers (CFRP) and Glass Fiber Reinforced Polymers (GFRP) subjected to quasi- static loading is presented in the work. The hysteresis behaviour, stiffness retention, energy dissipation and damage index are the parameters employed to analyze the efficacy of FRP strengthening of bare and brick in-filled RC frames. It is observed that there is a significant improvement in load carrying capacity of brick infilled frame over bare RC frame. Also FRP strengthened brick infilled frame performs much better than FRP repaired bare frame under quasi static loading. Repair and retrofitting of brick infilled RC frame shows an improved load carrying and damage tolerance capacity than control frame.

Shear Strength Prediction of FRP RC Baem without Shear Reinforcements (전단 보강이 없는 FRP RC보의 전단강도 예측)

  • Lee, Jae-Hoon;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.313-324
    • /
    • 2010
  • There are many problems in application of FRP reinforcing bars as shear reinforcement, since bending of FRP bars is not a feasible process on construction site. Even though FRP bars can be manufactured in bent shape, they have lower strength at bent location. However, there are no serious problems to use FRP bars as flexural reinforcement. Plates or slabs like bridge decks, in general, do not need shear reinforcements. These types of members with FRP flexural reinforcement have lower shear strength than those with conventional steel flexural reinforcement. However, reliable process or equation for shear strength estimation of FRP reinforced concrete without shear reinforcement are not established, yet. In this study, predicted shear strength obtained from available design equations and assessment equations are compared with 211 experimental results. The results showed that among the current design codes, the Architectural Institute of Japan (AIJ) and the Institution of Structural Engineers (ISE) provided the best estimation. ACI 440.1R-06 provided conservative results with degree of dispersion similar to that of ISE. In addition, regression analysis on the collected experimental results was conducted to develop regression models. As a result, a new reliable shear strength equation was proposed.

Prediction of the Shear Strength of FRP Strengthened RC Beams (I) - Development and Evaluation of Shear strength model - (FRP로 전단 보강된 철근콘크리트 보의 전단강도 예측 (I) - 전단강도 예측 모델제안 및 검증 -)

  • Sim Jong-Sung;Oh Hong-Seob;Moon Do-Young;Park Kyung-Dong
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.343-351
    • /
    • 2005
  • This study developed a shear strength prediction model of FRP strengthened reinforced concrete beams in shear. The primary design parameters were shear crack angle and shear span to depth ratio of FRP reinforcement. Of primary concern In the suggested model was the FRP debonding failure, which Is a typical fracture mode of RC beams strengthened with FRP, The proposed model used a crack sliding model based on modified plasticity theory. To address the effect of the shear span to depth ratio, the arch action was considered in the proposed model. The proposed model was applied to RC beams strengthened with FRP. The results showed that the proposed model agree with test results.

Experimental Evaluation on Strengthening of NSM and! Section Increment with FRP Rebars (FRP 보강근을 이용한 표면매립 및 단면확대공법의 실험적 성능평가)

  • 정상모;이차돈;원종필;황윤국;김정호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.549-554
    • /
    • 2003
  • In order to overcome the brittle failure of strengthening with FRP-rebars inherent to their brittle properties, two approaches have been attempted. One is to improve the properties like ductile Hybrid FRP Rods, and the other is to develop a ductile strengthening with partially unbonded FRP rebars. Experiments on real size specimen were performed to evaluate the performance of NSM (Near Surface Mounted Strengthening) and SIM (Section Increment Methods) with FRP rebars. This paper discusses the results of the tests on 8 slab specimen in terms of flexural resistance, ductility, and fatigue. They show that NSM or S1M with FRP rebars are very effective measures to strengthen existing RC structures. Above all, strengthening with partially unbonded ductile Hybrid FRP Rods shows sufficient ductility similar to that of properly designed RC structures.

  • PDF

Experimental Evaluation for Seismic Performance of RC Bridge Piers with FRP Confinement (FRP 횡보강근을 이용한 RC 교각의 내진성능 평가 실험)

  • 정영수;박진영;박창규;서진원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.377-384
    • /
    • 2003
  • Recently, there are much concerns about new and innovative transverse materials which could be used instead of conventional transverse steel in reinforced concrete bridge piers. FRP materials could be substituted for conventional transverse steel because of their sufficient strength, light weight, easy fabrication, and useful applicability to any shapes of pier sections, such as rectangular or circular sections. The objective of this research is to evaluate the seismic performance of reinforced concrete bridge pier specimens with FRP transverse reinforcement by means of the Quasi-Static test. In the first task, test columns were made using FRP rope, but these specimens appeared to fail at low displacement ductility levels due to insufficient confinement of strand extension itself. Therefore, the second task was to evaluate the seismic performance of test specimens transversely confined with FRP band. Although FRP banded specimens showed lower seismic performance than the specimen with spiral reinforcing steel, it satisfied with the response modification factor, 3, required for the single column of Korea bridge roadway design code. It was concluded that FRP band could be efficiently substituted for conventional reinforcing steel.

  • PDF

Strengthening of deficient RC joints with diagonally placed external C-FRP ropes

  • Karayannis, Chris G.;Golias, Emmanouil
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.123-132
    • /
    • 2021
  • Deficient beam-column joints of reinforced concrete (RC) structures designed to older practices and codes often lead to destructive local or global failures. A strengthening technique for these joints based on the use of the new and innovative Carbon-FRP (C-FRP) ropes is presented and investigated. The C-FRP ropes are diagonally placed in superficial notches on the two sides of the joint. Two full scale external substandard joint subassemblages with the same characteristics, one unstrengthened and one strengthened with diagonally applied C-FRP ropes, are constructed and tested in cyclic loading. Special attention has been given to the elaboration of the acquired test measurements. The extracted conclusions are based on the comparative study of the hysteretic responses of the specimens, the observed maximum load envelopes, the comparisons of the joint body shear deformations as measured using diagonally mounted LVTDs, the calculated nominal principal stresses developed in the joint regions, the assessed joint damage as expressed by the damage index by Park and Ang and finally the calculated values of the equivalent damping ratio. From these comparisons it is concluded that application of diagonally mounted C-FRP ropes on the two sides of the joint body of exterior connections is an efficient easy-to-apply technique for the strengthening of substandard RC joints.

A Study on Shear Strength Prediction of RC Columns Strengthened with FRP Sheets (섬유 쉬트로 보강된 철근콘크리트 기둥의 전단강도 예측에 관한 연구)

  • 변재한;권성준;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.896-901
    • /
    • 2003
  • This paper describes a model on shear strength of RC columns strengthened with FRP sheets. In this study, we propose a confined concrete strength model of RC columns confined by transverse reinforcement as well as FRP sheet by introducing corresponding effective confinement coefficient for each confined concrete area. Then, a shear strength model of the confined RC columns is proposed by lower and upper bound limit analysis which are based on the truss-arch model theory and shear band failure theory, respectively. Along with shear test data obtained from strengthened column specimens, the developed analytical models are verified. The comparison shows that the proposed model can be used effectively for the prediction of both ultimate strength and required amount of strengthening in retrofit design for RC columns.

  • PDF

Retrofit Capacity of Near-Surface-Mounted RC Beam by using FRP Plate (FRP 판으로 표면매입 보강된 철근콘크리트 보의 보강성능)

  • Seo, Soo Yeon;Choi, Ki Bong;Kwon, Yeong Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, research about Near-Surface-Mounted Rertofit (NSMR) method has been being widely performed as a method for retrofit of RC structure using FRP. This method requires additional work to make grooves during retrofit but makes it possible to improve retrofit effect and reduce the attack by environment. In this paper, the retrofit effect of NSMR method, especially the method using FRP plate instead of bar is investigated through experiment. Six RC beams were made and retrofitted using by FRP plate following the planned methods; Surface-Bonding Retrofit (SBR), NSMR without debonding region and NSMR with debonding region. Flexural capacity of all specimens was evaluated by beam test with simple support condition. As a result, NSMR method with FRP plate had more improved structural capacity than SBR method. The calculation process of ACI 440-2R can be used to predict the member retrofitted by NSMR with FRP plate with consideration on the three anchorage failure mechanism.

Shear Capacity of the RC T Beams Strengthened for Shear with NSM FRP Strips (FRP 판으로 표면매립 전단보강된 철근콘크리트 T형 보의 전단성능)

  • Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.256-262
    • /
    • 2022
  • The purpose of this study is to define the shear reinforcing effect of Near-Surface-Mounted (NSM) FRP strips in reinforced concrete (RC) member through a test. Three T shaped RC beams were made and two of them were strengthened with NSM FRP strips for increase shear strength. And those were tested to find the shear strengthening effect. In the test, two case of shear strengthening methods were considered such as 1) with NSM FRP strips having full embedded length and 2) with NSM FRP strips having some what short embedded length and additional externally bonded FRP sheet. As a result, the shear strengthening effect could be obtained when the NSM FRP strips are embedded to have full length up to the bottom of slab. However the shear strength was not increased in the case of having somewhat short embedded length of NSM FRP strips even additional EB sheet was enhanced.