• Title/Summary/Keyword: FRP 복합재료

Search Result 199, Processing Time 0.028 seconds

Numerical Study of Lightweight FRP Bridge Deck System induced by Thermal Stress by Fire (화재 발생시 열응력에 의한 복합재료 과량 시스템의 거동에 관한 연구)

  • Jung Woo-Young;Lee Hyung-Kil;Park Hui-Kwang;Shim In-Seob;Song Young-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.928-931
    • /
    • 2006
  • Due to their light weight, high stiffness-to-weight and strength-to-weight ratios, and potentially high resistance to environmental degradation, resulting in lower life-cycle costs, polymer composites, are increasingly being considered for use in civil infrastructure applications. Recently, an FRP deck has been installed on a state highway, located in New York State. In this study, a thermal stress analysis was conducted using finite element method to study failure mechanisms of the superstructure. This analysis evaluated small and large temperature gradient effects on the FRP deck considering lightweight of FRP deck and ply orientations at the interface between steel girders and FRP deck Finite element model was verified using the load tests of the bridge deck. Finally, the analytical results shows the possible failure mechanism of FRP deck under various temperature changes and its corresponding index is suddenly varied depending on the rapid change of temperature on the deck plate.

  • PDF

Ductile Effect of Hybrid Fiber Reinforced Composite Rebar (하이브리드 섬유강화 복합재료 리바의 연성효과)

  • Choi, Myung-Sun;Han, Gil-Young;Lee, Dong-Gi;Ahn, Dong-Gue
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.112-116
    • /
    • 2003
  • This paper describes the need for a ductile of Fiber Reinforced Plastic(FRP) reinforcement for concrete structures. The criteria to be met by the FRP, which are based on the properties of the steel rebar it is to replace, are threefold: high initial modulus, a definite yield point and a high level of ultimate strain. It is shown that the use of a fiber architecture based design methodology facilitates the optimization of the performance of FRP through material and geometric hybrid. Ductile hybrid FRP bars were successfully fabricated at 3mm and 5mm nominal diameters using an in-line braiding and pultrusion process.

  • PDF

Performance Enhancement of Floating PV Generation Structure Using FRP (FRP를 활용한 부유식 태양광발전 구조시스템의 성능 향상)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Hwang, Seong-Tae;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • In this study, we suggest the new floating PV generation structure which is improved the structural and economical efficiency compared with the system developed in the previous research. Pultruded FRP has superior physical and chemical material properties compared with those of conventional structural materials. Especially, pultruded FRP has an excellent corrosion-resistance, light-weight, and it also has high specific strength and stiffness which are highly appreciated for the design and fabrication of floating PV generation structure under harsh environmental condition. In this study, structural analysis using the finite element method has been performed to investigate the safety of new floating PV generation structure and newly applied structural members.

An Analysis of Simplified Cable Stayed Bridge with FRP Components (FRP 부재를 이용한 단순 사장교 모델의 거동 해석)

  • Park, Jae-Gyun;An, Il-Chan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.543-550
    • /
    • 2007
  • As an emerging materials in construction fields, FRP(fiber reinforced polymer) has been used in many area of civil engineering for its light weight and high strength. In this study we chose the 2nd Jindo-Bridge as a prototype, and evaluate effect of replacing steel components to FRP components through simplified 3D linear analysis. Static and modal analysis are done and the analysis results are compared with steel case analysis. From the static analysis results, the maximum stress of each component and maximum displacement of middle span are compared. Due to the reduction of deadload, the FRP structure causes less deflection than the original steel structure and from the reduced section (cable) analysis we confirmed the previous result. The occurrence wind velocity of flutter is compared by the frequency ratio.

Effect of Second Phase on the Conduction Path Forming in Composites FRP by Computer Simulation (컴퓨터 시뮬레이션에 의한 FRP 복합재료의 도전경로 형성에 미치는 제2상의 영향)

  • Shin, Soon-Gi;Lim, Hyun-Ju;Lee, Jun-Hee
    • Korean Journal of Materials Research
    • /
    • v.13 no.11
    • /
    • pp.756-760
    • /
    • 2003
  • Two dimensional computer simulations were conducted on percolative structure in which second phases with various short diameter were arranged in matrix phase. In case of prohibiting the overlap among the second phases, the maximum area fraction of second phase arranged in matrix was increased with higher short diameter. In case of allowing the overlap among the second phases, the critical area fraction was increased with higher short diameter and the total number of distributed second phase was decreased. This results represented that thickness variation of short diameter by grain growth on the production processes affect significantly forming the completion path.

Surface Properties of Epoxy Composites by Plasma Treatment (플라즈마처리에 따른 에폭시 복합재료의 표면특성)

  • 임경범;이백수;이덕출
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.10
    • /
    • pp.821-827
    • /
    • 2001
  • In this study performed to identify a degradation mechanism in macromolecular insulating material, the contact angel, surface potential decay, surface resistivity, and XPS analysis were compared after exposure of FRP laminate to plasma discharge. In the case of contact angle, the surface of specimen untreated showed weak hydrophobic property of 73。. However, the contact angle was decreased to 20。in the plasma-treated specimen. In the case of chemical changes arising form plasma treatment, carboxl radicals were generated mainly in the surface treated, which was rapidly changed to the hydrophilic one. In the corona potential decay study to determine the electrical changes of the surface, positive charges were rapidly decreased when compared with negative charges, leading to negative property in the surface of specimen not treated. However, in the case of the hydrophilic surface, lots of carboxl radicals acting as positive polarity were generated, resulting in positive surface. Owing to such positive surface, charges of negative polarity applied were rapidly decreased.

  • PDF

An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting (긴급시공이 가능한 FRP 복합재료 보강재로 보강된 기둥의 내진성능평가)

  • Kim, Jin-Sup;Seo, Hyun-Su;Lim, Jeong-Hee;Kwon, Min-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. In the past, cross-sectional extension method, a steel plate reinforcing method and fiver-reinforced method are applied to Seismic Rehabilitation Technique mainly. However, the reinforcement methods have drawbacks that induce physical damage to structures, large space, long duration time. So, in this study, performance evaluation of previously developed FRP seismic reinforcement which do not induce physical damage and short duration time was enforced. The specimens were constructed with 80% downscale. FRP seismic reinforcement are manufactured of glass fiber or aluminum plate with holes and glass fiber. From the experiment results, seismic performance of specimens which reinforced with FRP seismic reinforcement were increased.

Model for fiber Cross-Sectional Analysis of FRP Concrete Members Based on the Constitutive Law in Multi-Axial Stress States (다축응력상태의 구성관계에 기초한 FRP 콘크리트 부재의 층분할 단면해석모델)

  • 조창근;김영상;배수호;김환석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.892-899
    • /
    • 2002
  • Among the methods for enhancement of load-carrying capacity on flexural concrete member, recently, a concept is being investigated which replaces the steel in a conventional reinforced concrete member with a fiber reinforced polymer(FRP) shell. This study focuses on modeling of the structural behavior of concrete surrounded with FRP shells in flexural bending members. A numerical model of fiber cross-sectional analysis is proposed to predict the stress and deformation state of the FRP shell and concrete. The stress-strain relationship of concrete confined by a FRP shell is formulated to be based on the constitutive law of concrete in multi-axial compressive stress state, in assuming that the compression response is dependent on the radial expansion of the concrete. To describe the FRP shell behavior, equivalent orthotropic properties of in-plane behavior from classical lamination theory are used. The present model is validated to compare with the experiments of 4-point bending tests of FRP shell concrete beam, and has well predicted the moment-curvature relationships of the members, axial and hoop strains in the section, and the enhancement of confinement effect in concrete surrounded by FRP shell.

탐촉자의 접촉방식에 따른 복합재 연소관의 초음파탐상 기법 연구

  • 나성엽;임수용;김동륜
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.22-22
    • /
    • 2000
  • 본 연구에서는 초음파 탐촉자의 접촉방식을 다양화하여 Immersion법/Bubbler법/Squirtor법으로 복합재 연소관을 탐상하는 방법에 대하여 연구하였으며, 이를 위하여 FRP의 delamination, FRP-EPDM간의 미접착을 모사한 복합재 연소관 모의결함시편을 제작하여 시험하였다. Immersion법에서는 일반적으로 사용되는 방법을 적용하였으며 Bubbler 및 Squirter법에서는 자체적으로 설계 및 제작한 치구를 이용하여 시험하였다. 이들 각 방법에 대하여 복합재 연소관 모의결함 시편의 결함부위에 대한 초음파 신호를 A-scan으로 비교하고 또한 C-scan하여 결함의 검출 정도를 비교하였다. 그리고 시험 자료를 바탕으로 데이터 값을 분석함으로써 복합재 연소관에서의 초음파 속도, 음향 임피던스, 반사율 및 투과율 등 복합재료의 초음파 특성을 산출하였으며 또한 건전신호와 결함신호에 대한 분류기준을 제시하였다.

  • PDF

The Study on Potential Characteristics and Corona Discharge of Composite Insulating Material (복합절연재료 FRP의 코로나 대전파 전위감쇄특성에 관한 연구)

  • 이백수;신태현;김진식;강대하;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.365-368
    • /
    • 1995
  • Charge decay, thermally stimulated current (TSC), charging and discharging currents(I) are measured for corona-charged composite insulating materials. In this study, We will make an experiment in charge decay on composite material surface, TSC, polarity effect and the others in order to analysis its mechanism. Especially, Fiber glass Reinforced Plastics(FRP) is the best composite material which has been so far. Therefore, Its worthy of notice to investigate its characteristic. And then some other materials will be focused on. This experiment measured characteristic of charge decay, dependence of discharging-time and other electrostatic characteristics on FRP.

  • PDF