• Title/Summary/Keyword: FPI

Search Result 84, Processing Time 0.03 seconds

Traumatic Contusion of ICR Mouse Brain by FPI : $^{1}\textrm{H}$ MR Spectroscopic Study (유체타진손상기법에 의한 ICR 쥐의 뇌손상: 자기공명분광법)

  • Park, Chi-Bong;Kim, Hwi-Yool;Jeun, Sin-Soo;Han, Young-Min;Han, Duk-Young;Kang, Young-Woon;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.259-267
    • /
    • 2003
  • In vivo $^1$H magnetic resonance spectroscopy (MRS) at 4.7 T was applied to investigate the cerebral metabolite changes of mice brain before and after experimental brain trauma. In vivo $^1$H MR spectra were acquired from a voxel covering right parietal cortex in normal brain, used as control subjects. After experimental brain trauma using the fluid percussion injury (FPI) method, $^1$H MR spectra were acquired from the same lesion three days after trauma. Metabolite ratios of the injured lesion were compared to those of controls. After trauma, N-acetylaspartate (NAA)/creatine (Cr) ratio, as a neuronal marker was decreased significantly versus controls, indicating neuronal loss. The ratio of NAA/Cr in traumatic brain contusion was 0.90$\pm$0.11, while that in normal control subjects was 1.13$\pm$0.12 (P=0.001). Choline (Cho)/Cr ratio had a tendency to rise in experimental brain contusion (P=0.02). Cho/Cr ratio after trauma was 0.91$\pm$0.17 while that before traumas was 0.76$\pm$0.15. Cho/Cr ratio was increased and this might indicate a inflammatory activity. However, no significant difference of [(glutamate+glutamine) (Glx)]/Cr was established between experimental traumatic brain injury models and normal controls. Lactate (Lac)/Cr ratio was appeared as a sign of shifted posttraumatic energy metabolism and increased versus controls. These findings strongly suggest that in vivo $^1$H MRS may be a useful modality for clinical evaluation of traumatic contusion and could aid in better understanding the neuropathologic process of traumatic contusion induced by FPI. In the present study, in vivo $^1$H MRS was proved to be a useful non-invasive method for in vivo diagnosis and monitoring of posttraumatic metabolism in models of brain contusion.

  • PDF

Fingerprint Image for the Randomness Algorithm

  • Park, Jong-Min
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.539-543
    • /
    • 2010
  • We present a random bit generator that uses fingerprint image for the source of random, and random bit generator using fingerprint image for the randomness has not been presented as yet. Fingerprint image is affected by the operational environments including sensing act, nonuniform contact and inconsistent contact, and these operational environments make FPI to be used for the source of random possible. Our generator produces, on the average, 9,334 bits a fingerprint image in 0.03 second. We have used the NIST SDB14 test suite consisting of sixteen statistical tests for testing the randomness of the bit sequence generated by our generator, and as the result, the bit sequence passes all sixteen statistical tests.

Purification and Characterization of Metalloproteases from Pleurotus sajor-caju

  • SHIN, HYUN-HEE;HYE-SEON CHOI
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.5
    • /
    • pp.675-678
    • /
    • 1999
  • Fibrinolytic protease activity was detected in the fruit body of Pleurotus sajor-caju using a fibrin plate method. Two fibrinolytic activities (FPI and Ⅱ) were found at the regions of 14.5 and 86.0 kDa by using gel-filtration column chromatography. FPⅡ was identified as an alkaline protease, whereas FPⅠ was a neutral protease. Both were inhibited by phenanthrolin and EDTA, suggesting that they are metalloprotease. Inactivated enzyme activities were restored by adding Co/sup 2+/ or Zn/sup 2+/. Iodoacetate inhibited FPⅠ, but not FPⅡ. Both enzymes cleaved B/sub β/ and γ chains of the human fibrinogen. FPⅡ showed a preference to hydrophobic and bulky residues of nitroanilidine compounds as substrates, whereas FPⅠ preferred positively charged residues.

  • PDF

Pool Boiling Heat Transfer Coefficients of Hydrocarbon Refrigerants on Various Enhanced Tubes (열전달 촉진관에서 탄화수소계 냉매의 풀비등 열전달계수)

  • Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1017-1024
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of five hydrocarbon refrigerants of propylene, propane, isobutane, butane and dimethylether (DME) were measured at the liquid temperature of $7^{\circ}C$ on a 26 fpi low fin tube, Turbo-B, and Thermoexcel-E tubes. All data were taken from 80 to $10kW/m^2$ in the decreasing order of heat flux. The data of hydrocarbon refrigerants showed a typical trend that nucleate boiling HTCs obtained on enhanced tubes also increase with the vapor pressure. Fluids with lower reduced pressure such as DME, isobutane, and butane took more advantage of the heat transfer enhancement mechanism of enhanced tubes than those enhancement ratios of $2.3\sim9.4$ among the tubes tested due to its sub-channels and re-entrant cavities.

Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers (핀-관 열교환기에서 개별 열의 열전달 효과)

  • Jeong, Ji-Hwan;Chang, Keun-Sun;Lee, Hyun-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.238-244
    • /
    • 2003
  • An experimental study was performed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance was measured using air-enthalpy type calorimeter. The examined heat exchangers consists of $7{\Phi}$ tube and fin patterns of them are slit and louver types. Equivalent fin spacing are 18 FPI for all samples, and the number of tube rows were 2. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers were used. The frontal air velocity varied from 0.7 to 2.5 m/s. Heat transfer performance for each row are measured. It was observed that the heat transfer coefficient of the 2nd row were smaller than that of the 1st row at low Reynolds number while larger at high Reynolds number.

  • PDF

The Assessment of Food Procurement Practices in Elementary School Foodservices Located in Kyungkido (초등학교 급식소의 식품구매 실태조사 -경기도 지역을 중심으로-)

  • 유양자;윤선주
    • Korean journal of food and cookery science
    • /
    • v.13 no.3
    • /
    • pp.319-329
    • /
    • 1997
  • Food procurement practices in elementary schools were evaluated to provide basic information for the efficient foodservice management. Total 85 self-completed questionnaires were collected out of 134 dieticians working for elementary schools in Kyungkido, and analyzed for demographic background, purchasing activities and processing-food utilization status. The results were as follows: 1. The elementary schools were located in urban (22.0%), provincial (58.5%), and isolated areas (19.5%). 2. 62.4% of them were conventional schools and rest of them were commissary schools (37.6%). 3. As the total meals produced in schools increased, the number of meals served per foodservice staff and the workload increased, and more foods were purchased through wholesalers and competitive bids. 4. There were no significant differences (p > 0.05) in food procurement practices by the location, type of foodservice systems and the size of schools. 5. As the number of total meals in schools increased, the level of FPI (Food Processing Index) points for meat products, fish products, kimchi and sauce decreased.

  • PDF

Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers (2열 핀-관 열 교환기의 열별 전열성능 측정)

  • 권영철;정지환;장근선;홍기수;진심원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

Heat Transfer Characteristics of Oval-Tube Heat Exchanger (타원관 열교환기의 열전달 특성)

  • 윤점열;이욱용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.292-301
    • /
    • 2000
  • This study experimentally investigates an air-side performance of oval tube heat exchanger against round tube heat exchanger using scaled-up model experiment for home air conditioners. A plain fin and round tube heat exchanger with 21 FPI(fins per inch) was used as a reference heat exchanger, and these were applied equally to 4 oval tube heat exchangers. Oval tube samples were designed with the same perimeter as 7.5mm diameter round tube, and their aspect ratios were 1:2, 1:3, respectively. In this study, the heat transfer and pressure drop characteristics of oval tube heat exchangers against round tube heat exchanger were also compared to one another, and an optimal samples for home air conditioners was recommended. And, general performance characteristics for an optimum oval tube samples chosen in this work was compared with round tube heat exchanger.

  • PDF

An Ultra-narrow Bandwidth Filter for Daytime Wind Measurement of Direct Detection Rayleigh Lidar

  • Han, Fei;Liu, Hengjia;Sun, Dongsong;Han, Yuli;Zhou, Anran;Zhang, Nannan;Chu, Jiaqi;Zheng, Jun;Jiang, Shan;Wang, Yuanzu
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.69-80
    • /
    • 2020
  • A Rayleigh Lidar used for wind detection works by transmitting laser pulses to the atmosphere and receiving backscattering signals from molecules. Because of the weak backscattering signals, a lidar usually uses a high sensitivity photomultiplier as detector and photon counting technology for signal collection. The capturing of returned extremely weak backscattering signals requires the lidar to work on dark background with a long time accumulation to get high signal-to-noise ratio (SNR). Because of the strong solar background during the day, the SNR of lidar during daytime is much lower than that during nighttime, the altitude and accuracy of detection are also restricted greatly. Therefore this article describes an ultra-narrow bandwidth filter (UNBF) that has been developed on 354.7 nm wavelength of laser. The UNBF is used for suppressing the strong solar background that degrades the performance of Rayleigh wind lidar during daytime. The optical structure of UNBF consists of an interference filter (IF), a low resolution Fabry-Perot interferometer (FPI) and a high resolution FPI. The parameters of each optical component of the UNBF are presented in this article. The transmission curve of the aligned UNBF is measured with a tunable laser. Contrasting the result of with-UNBF and with-IF shows that the solar background received by a Licel transient recorder decreases by 50~100 times and that the SNR with-UNBF was improved by 3 times in the altitude range (35 km to 40 km) compared to with-IF at 10:26 to 10:38 on August 29, 2018. By the SNR comparison at four different times of one day, the ratio-values are larger than 1 over the altitude range (25~50 km) in general, the results illustrate that the SNR with-UNBF is better than that with-IF for Rayleigh Lidar during daytime and they demonstrate the effective improvements of solar background restriction of UNBF.

An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution (낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.591-598
    • /
    • 2015
  • Pool boiling heat transfer coefficients of a LiBr solution were obtained for seven low fin tubes having different fin pitch and fin height. The test range covered saturation pressure from 7.38kPa to 101.3kPa, heat flux from $20kW/m^2$ to $40 kW/m^2$ and LiBr concentration from 0% to 50%. The optimum fin geometry for the present experimental range turned out to be 26 fpi with 0.18 mm fin height.The advantage of added heat transfer area and the disadvantage of slower bubble growth and departure appear to have yielded an optimum fin pitch. The heat transfer coefficient decreased as saturation pressure decreased and Libr concentration increased. The reason may be attributed to the low saturation pressure, which increased the bubble departure diameter and decreased the bubble departure frequency. As the LiBr concenreation increased, the saturation temperature increased and the mass diffusion rate decreased, which resulted in a reduced heat transfer coefficient. The heat transfer coefficients of the low fin tube were greater than those of the smooth tube. Correlations were developed based on the present data.