• Title/Summary/Keyword: FPD

Search Result 341, Processing Time 0.025 seconds

Defect Inspection of FPD Panel Based on B-spline (B-spline 기반의 FPD 패널 결함 검사)

  • Kim, Sang-Ji;Hwang, Yong-Hyeon;Lee, Byoung-Gook;Lee, Joon-Jae
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.10
    • /
    • pp.1271-1283
    • /
    • 2007
  • To detect defect of FPD(flat panel displays) is very difficult due to uneven illumination on FPD panel image. This paper presents a method to detect various types of defects using the approximated image of the uneven illumination by B-spline. To construct a approximated surface, corresponding to uneven illumination background intensity, while reducing random noises and small defect signal, only the lowest smooth subband is used by wavelet decomposition, resulting in reducing the computation time of taking B-spline approximation and enhancing detection accuracy. The approximated image in lowest LL subband is expanded as the same size as original one by wavelet reconstruction, and the difference between original image and reconstructed one becomes a flat image of compensating the uneven illumination background. A simple binary thresholding is then used to separate the defective regions from the subtracted image. Finally, blob analysis as post-processing is carried out to get rid of false defects. For applying in-line system, the wavelet transform by lifting based fast algorithm is implemented to deal with a huge size data such as film and the processing time is highly reduced.

  • PDF

A FINITE ELEMENT STRESS ANALYSIS OF FIXED PARTIAL DENTURE SUPPORTED BY OSSEOINTEGRATED IMPLANT AND THE NATURAL TEETH WITH REDUCED ALVEOLAR BONE HEIGHT (감소된 치조골 고경을 갖는 치아와 골유착성 임프랜트에 의해 지지되는 고정성 국소의치의 유한요소법적 응력분석)

  • Choi Choong-Kug;Kay Kee-Sung;Cho Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.296-326
    • /
    • 1994
  • The purpose of this study was to evaluate the mechanical effects when one implant fixture was connected to the natural teeth with reduced alveolar bone height. This study also examined the effects of increasing the number of abutment teeth and the effects of the intramobile connector and the titanium connector as they were inserted between the implant superstructure and the fixture. The distribution and concentration load was applied to the fixed partial denture(FPD) supported by implant and the natural teeth with reduced alveolar bone height. The stress and displacement of each element was observed and compared by the two-dimensional finite element method. The following results were obtained : 1. The greater the loss of alveolar bone in natural teeth area, the greater the displacement of FPD and the stress concentration in alveolar bone around implant, especially at the stress concentration in the mesial alveolar bone crest around implant fixture. 2. The displacement of FPD was increased more and that of implants fixture was decreased more when intramobile connector was used than titanium connector was used. Also the stress concentration in alveolar bone around implant fixture was greater when intramobile connector than titanium connector. One implication of this finding was that the difference in stiffness of implant and the natural teeth with reduced alveolar bone height could be partially compensated in case of the POM intramobile connector. 3. The amount and direction of displacement and the stress distribution of the 4-unit FPD was better than those of the 3-unit FPD. It implied that the difference of stiffness of implant and natural teeth with reduced alveolar bone height could be partially compensated in case of the 4 unit FPD.

  • PDF

Studies on Pretreatment for Analysis of Pesticides by Using HPLC and GC (HPLC 및 GC에 의한 농약분석에서 전처리에 대한 연구)

  • Oh, Bo Young;Bae, Jun Hyun;Kang, Jun Gil;Kim, Youn Doo
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.6
    • /
    • pp.663-669
    • /
    • 1999
  • For determination of separated pesticides by using GC and HPLC, liquid-liquid extraction(LLE) and solid phase extraction(SPE) have been carried out to separate and concentrate the organophophorous pesticides such as Diazinon, Fenitrothion, Phosmet, Phosalon and EPN in environmental water samples. ln determination of pesticides by HPLC/UV, SPE has resulted in higher recovery and more precision than LLE, while in determination of pesticides by GC/FPD, vice versa. HPLC/UV after the pretreatment process of sample by solid phase extraction (SPE-HPLC/UV) has suggested the possibility of determination of pesticides ppb level. ln comparison of detection limit, both SPE-HPLC/UV and LLE-GC/FPD are reasonably suitable for analysis of residue pesticides. ln the respect of the rapidity and the solvent required, SPE-HPLC/UV method has proven to be superior to LLE-GC/FPD.

  • PDF

Magnetic Levitated Electric Monorail System for Flat Panel Display Glass Delivery Applications (FPD 공정용 Glass 이송 시스템을 위한 자기부상 EMS의 개발)

  • Lee, Ki-Chang;Moon, Ji-Woo;Koo, Dae-Hyun;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.566-572
    • /
    • 2011
  • In recent semiconductor and FPD (Flat Panel Display) manufacturing processes, high clean-class delivery operation is required more and more for short working time and better product quality. Traditionally SLIM (Single-sided Linear Induction Motor) is widely used in the liner drive applications because of its simplicity in the rail structure. A magnetically levitated (Maglev) unmanned vehicle with SLIM traction, which is powered by a CPS (Contactless Power Supply) can be a high precision delivery solution for this industry. In this paper unmanned FPD-carrying vehicle, which can levitate without contacting the rail structure, is suggested for high clean-class FPD delivery applications. It can be more acceptable for the complex facilities composed with many processes which require longer rails, because of simple rail structure. The test setup consists of a test vehicle and a rounded rail, in which the vehicle can load and unload products at arbitrary position commanded through wireless communications of host computer. The experimental results show that the suggested vehicle and rail have reasonable traction servo and robust electromagnetic suspensions without any contact. The resolution of point servo errors in the SLIM traction system is accomplished under 1mm. The maximum gap error is ${\pm}0.25mm$ with nominal air gap length of 4.0mm in the electromagnetic suspensions. This type of automated delivery vehicle is expected to have significant role in the clean delivery like FPD glass delivery.

Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

  • Bowley, John Francis;Kaye, Elizabeth Krall;Garcia, Raul Isidro
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.278-286
    • /
    • 2017
  • PURPOSE. The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS. Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS. Low levels of vertical wall taper, ${\leq}10-degrees$, were needed to resist rotational displacement in all wall height categories; 2-to-6-degrees is generally considered ideal, with 7-to-10-degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION. The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form.

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

Time Resolved Photometric and Colorimetric 2D Measurements of both Dynamic and Static Luminance- and Colour Artifacts in FPD.

  • Jensen, Jens Joergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.947-950
    • /
    • 2008
  • This paper reports of traceable and repeatable time resolved colorimetric measurements of the luminance- and colour variation occurring during the frame refresh period of FPD's. During one frame period a number of measurements are performed, and for the dynamic artifacts a simulated smooth pursuit eye tracking algorithm is included.

  • PDF

비접촉 3차원 검사장비의 기술동향 및 시장동향

  • 유인상
    • The Optical Journal
    • /
    • v.14 no.4 s.80
    • /
    • pp.56-58
    • /
    • 2002
  • 최근들어 FPD(평판 디스플레이), MEMS, 반도체, 광부품 등의 분야에서 극미세화의 경향이 보이고 있다. 이들의 가공기술과 더불어 검사장비 역시 2차원 마이크로미터의 수준에서 3차원 나노미터 정밀도를 갖는 장비로 급속도로 교체되고 있는 것이 현실이다. 본 고에서는 반도체에 이어 한국의 기술력을 세계 1위로 끌어올린 FPD 분야에서 3차원 검사장비의 활용을 중심적으로 기술 및 시장동향을 살펴보고자 한다.

  • PDF