• Title/Summary/Keyword: FM1

Search Result 728, Processing Time 0.028 seconds

Digital demodulator design and characteristics of AM and FM signals by undersampling scheme (Undersampling 기법에 의한 AM 및 FM 신호의 디지털 복조기 설계와 특성)

  • 손태호;박종연
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.116-126
    • /
    • 1997
  • As the digital system with high sampling rates is required to process numerous data, it is difficult to realize the real time processing for this system. By using the nonlinear energy tracking signal operator, in this paper four kinds of AM/FM demodulators are proposed and designed by the undersampling scheme of decreasing the sampling rate. Particularly, the undersampling frequency and 3dB bandwidth are controllable of these systems and their conditions are respectively. Through the analysis of the designed detectors, useful results are obtained in respect to characteristics and errors.

  • PDF

Sound Synthesis of Piri by Asymmetric Frequency Modulation (비대칭 FM합성방식을 이용한 피리 소리의 합성)

  • Pyoun, Joong-Bae;Cho, Sang-Jin;Chong, Ui-Pil
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2006.06a
    • /
    • pp.37-40
    • /
    • 2006
  • FM(Frequency Modulation) 음 합성방식은 오랫동안 연구되어 왔고 여러 가지 효과를 주기에 유용하고 비교적 낮은 사양으로 높은 수준의 배음을 합성할 수 있지만 그 응용분야가 대부분이 서양악기 위주의 연구였다. 이에 본 논문에서는 국악 관악기인 피리를 주파수 영역에서 저주파 영역과 고주파 영역으로 나누어 분석하고 이 결과를 이용하여 FM 파라미터를 추출하고 비대칭 FM합성방식으로 1차적인 소리를 합성하였다. 분석된 저주파 영역과 고주파 영역의 특성을 각각의 역 필터링을 위한 2개의 필터를 설계하여 이를 다시 합성된 소리를 통과시켜 두 소리를 합산함으로써 더욱 원음과 유사한 소리를 합성할 수 있었다.

  • PDF

Coexistence of OFDM-Based IMT-Advanced and FM Broadcasting Systems

  • Shamsan, Zaid A.;Rahman, Tharek A.;Kamarudin, Muhammad R.;Al-Hetar, Abdulaziz M.;Jo, Han-Shin
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.279-282
    • /
    • 2011
  • Coexistence analysis is extremely important in examining the possibility for spectrum sharing between orthogonal frequency-division multiplexing (OFDM)-based international mobile telecommunications (IMT)-Advanced and other wireless services. In this letter, a new closed form method is derived based on power spectral density analysis in order to analyze the coexistence of OFDM-based IMT-Advanced systems and broadcasting frequency modulation (FM) systems. The proposed method evaluates more exact interference power of IMT-Advanced systems in FM broadcasting systems than the advanced minimum coupling loss (A-MCL) method. Numerical results show that the interference power is 1.3 dB and 3 dB less than that obtained using the A-MCL method at cochannel and adjacent channel, respectively. This reduces the minimum separation distance between the two systems, which eventually saves spectrum resources.

The Effects of Cudrania tricupidata Tea Leaves on the Blood Glucose and Serum Lipids Profiles of Streptozotocin-Induced Hyperglycemic Rats (꾸지뽕잎차 첨가 식이가 Streptozotocin으로 유발한 고혈당 흰쥐의 혈당 및 혈청지질 함량에 미치는 영향)

  • Park, Bum-Ho;Shin, Jong-Wook;Lee, Sang-Il;Kim, Soon-Dong
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.4
    • /
    • pp.516-523
    • /
    • 2008
  • The effects of pan-fired (PM) and fermented (FM) Cudrania tricupidata tea leaves on $\alpha$-glucosidase inhibitory activity, oral glucose tolerance, blood glucose levels and serum lipids profiles in streptozotocin (STZ)-induced hyperglycemic rats were investigated. The $\alpha$-glucosidase inhibitory activity of FM ethanol extracts (20 mg/mL) was higher (92.5%) than that of raw dried leaves (RM) (69.1%) and PM (54.6%). In addition, the results of a glucose tolerance test revealed that the glucose levels of hyperglycemic rats that were fed PM and FM ethanol extracts and then orally administered glucose began to decrease after 60 minutes, but recovered after 120 minutes. However, the blood glucose levels in the hyperglycemic control group did not begin to decrease for 360 minutes. Additionally, the results of animal experiments that were conducted over five weeks to compare the dietary effects of PM and FM following hyperglycemic induction to the effects on the hyperglycemic control group (DM) were as follows: The body weight gain and FER of the treated rats were $12.9{\sim}16.9%$ higher than those of the DM group, whereas the amounts of feed and water intake by the treated rats were $6.8{\sim}10.1%$ lower. Additionally, the levels of blood glucose and serum fructosamine decreased by $27.3{\sim}39.8%$ and $6.7{\sim}20.0%$, respectively, in the treated rats. Moreover, the serum triglyceride, total cholesterol and LDL-cholesterol concentrations in the treated rats were $24.9{\sim}27.1%$, $15.9{\sim}17.4%$ and $33.8{\sim}38.4%$ lower, respectively. Finally, the HDL-cholesterol contents were $20.5{\sim}24.8%$ higher in the treated rats than in the control group. The above results suggest that PM and FM exerts an anti-hyperglycemic effect that occurs due to the inhibition of $\alpha$-glucosidase activity as well as via prevention and/or inhibition of changes in the serum lipid profile. In addition, the results of this study revealed that the synthetic anti-hyperglycemic effect of FM was greater than that of PM. However, further detailed studies are needed to confirm these results.

  • PDF

Melt Rheology of Ethylene 1-Octene Copolymer Blends Synthesized by Ziegler-Natta and Metallocene Catalysts

  • Kim, Hak-Lim;Dipak Rana;Hanjin Kwag;Soonja Choe
    • Macromolecular Research
    • /
    • v.8 no.1
    • /
    • pp.34-43
    • /
    • 2000
  • The melt rheology of four binary blends of ethylene 1-octene copolymers (EOCs) which consist of one component by Ziegler-Natta and another by metallocene catalysts, was studied to elucidate miscibility in the melt by using torsion rheometer at 200$\^{C}$ and different shear rates. The four blend systems, designated into the FA+FM, SF+FM, RF+EN, and RF+PL blend, are divided and interpreted based on the melt index (MI), the density and the comonomer contents. The melt viscosity such asη', η", and η$\^$*/ is weight average value if the comonomer contents are similar, otherwise they show different manner. The experimental resole are analyzed based on the Cole-Cole plot of logη' uersus log η", the logarithmic plots of the dynamic storage modulus (G') versus the dynamic loss modulus (G") for various blend compositions, and the melt viscosity of 11', n", and f" as a function of blend compositions. As a cerise-quence, the FA+FM blend is miscible, but the SF+FM, RF+EN, and RF+PL blends are not in the melt. Thus miscibility of the blends studied in this communication is suggested to strongly influence by the comonomer contents rather than the density or the MI.

  • PDF

A Study on the Interference between CDMA Base Station and Analog FM Mobile Station in the Mobile Communication (이동통신의 CDMA 기지국과 Analog FM 이동국의 상호간섭에 관한 연구)

  • Kim, In-Hwan;Park, Chang-Gyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.105-113
    • /
    • 1995
  • For the case of using analog FM system and CDMA system together in the mobile communications, we experimentally calculate the appropriate frequency offset to improve the frequency efficiency by analizing the interference between both systems. As the results of the analysis, we obtained that frequency offset is 840KHz(Path Loss : 80dB) and 720KHz(Path Loss : 120dB) for the Path Loss when a output of CDMA Base Station is 0.91 W ERP. Therefore, to minimize the frequency offset, a output of Base Station will be controlled corresponding to Cover Area.

  • PDF

Conventional Posterior Approach without Far Lateral Approach for Ventral Foramen Magnum Meningiomas

  • Sohn, Seil;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.373-378
    • /
    • 2013
  • Objective : We present our experience of conventional posterior approach without fat lateral approach for ventral foramen magnum (FM) meningioma (FM meningioma) and tried to evaluate the approach is applicable to ventral FM meningioma. Methods : From January 1999 to March 2011, 11 patients with a ventral FM meningioma underwent a conventional posterior approach without further extension of lateral bony window. The tumor was removed through a working space between the dura and arachnoid membrane at the cervicomedullary junction with minimal retraction of medulla, spinal cord or cerebellum. Care should be taken not to violate arachnoid membrane. Results : Preoperatively, six patients were of Nurick grade 1, three were of grade 2, and two were of grade 3. Median follow-up period was 55 months (range, 20-163 months). The extent of resection was Simpson grade I in one case and Simpson grade II in remaining 10 cases. Clinical symptoms improved in eight patients and stable in three patients. There were no recurrences during the follow-up period. Postoperative morbidities included one pseudomeningocele and one transient dysphagia with dysarthria. Conclusion : Ventral FM meningiomas can be removed gross totally using a posterior approach without fat lateral approach. The arachnoid membrane can then be exploited as an anatomical barrier. However, this approach should be taken with a thorough understanding of its anatomical limitation.

Development of a miniaturized FM transmitter with low power

  • Ryu, Jeong-Tak;Kim, In-Gyeong;Kim, Yeon-Bo;Kim, Jong-Pil
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2008.10b
    • /
    • pp.629-633
    • /
    • 2008
  • Recently, there has been great interest in the application of short-range wireless communication system. In this paper, the miniaturized FM transmitter with low power is developed, and laboratory tests have been carried out. The FM transmitter uses FM radio waves to send sound from any system (MP3, PMP, PDA, MP3 Phone et.) to any nearby radio or stereo system. The transmitter is designed with $2.6cm{\times}2.6cm{\times}2.6cm$ system size. The operating voltage is 3.7 V and used the built-in storage battery. The system can use continuously during 7 hour with once charging. The transmission frequency can select one of 88.1 MHz, 88.3 MHz, or 88.5 MHz in compliance with utility condition. The channel separation ability is 40 dB. The operating temperature is $-10{\sim}+85^{\circ}C$, which use in the industry environment. Consequently, this system sis used conveniently with short distance information transmitter system at the industry field.

  • PDF

Effect of Proton Irradiation on the Magnetic Properties of Antiferromagnet/ferromagnet Structures

  • Kim, Dong-Jun;Park, Jin-Seok;Ryu, Ho Jin;Jeong, Jong-Ryul;Chung, Chang-Kyu;Park, Byong-Guk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.159-163
    • /
    • 2016
  • Antiferromagnet (AFM)/ferromagnet (FM) bilayer structures are widely used in the magnetic devices of sensor and memory applications, as AFM materials can induce unidirectional anisotropy of the FM material via exchange coupling. The strength of the exchange coupling is known to be sensitive to quality of the interface of the AFM/FM bilayers. In this study, we utilize proton irradiation to modify the interface structures and investigate its effect on the magnetic properties of AFM/FM structures, including the exchange bias and magnetic thermoelectric effect. The magnetic properties of IrMn/CoFeB structures with various IrMn thicknesses are characterized after they are exposed to a proton beam of 3 MeV and $1{\sim}5{\times}10^{14}ions/cm^2$. We observe that the magnetic moment is gradually reduced as the amount of the dose is increased. On the other hand, the exchange bias field and thermoelectric voltage are not significantly affected by proton irradiation. This indicates that proton irradiation has more of an influence on the bulk property of the FM CoFeB layer and less of an effect on the IrMn/CoFeB interface.

A Design of Ultra Compact S-Band PCM/FM Telemetry Transmitter (초소형 S-대역 PCM/FM 텔레메트리 송신기 설계 및 제작)

  • Jun, Ji-ho;Park, Ju-eun;Kim, Seong-min;Min, Se-hong;Lee, Jong-hyuk;Kim, Bok-ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.801-807
    • /
    • 2022
  • In this paper, we propose an ultra compact S-Band PCM/FM telemetry transmitter. The equipment is compact, so it can be applied to a limited space and capable of stable data transmission was designed and manufactured even with specifications set differently for each operating environment and system. RF direct conversion structure is used for the miniaturization of equipment, an RF transmission board, Power distribution board, and a signal processing board were implemented on a single PCB, so that the function of the transmitter could be performed with a minimum device. According to the target specification, variable output of 1~10W and variable data rate of 390kbps~12.5Mbps is possible in S-Band(2,200~2,400MHz) without degradation of performance. To verify the performance of the equipment, the RF performance test and BER measurement test were performed after the equipment was manufactured. It was confirmed that the OBW, null-to-null bandwidth, 1st IMD, Spurious emission, Phase noise specification of the PCM/FM modulated signal which is presented by the IRIG standard were satisfied, and we can confirm the data received using the transmitter inspection equipment were transmitted normally without distortion.