• Title/Summary/Keyword: FM signal

Search Result 174, Processing Time 0.047 seconds

The Analysis of Railway signal using DSP (DSP를 사용한 열차 신호 분석)

  • 김기승;김치조;임관수;조용기
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.194-201
    • /
    • 1998
  • It is extremely necessary to use such a secure way to transmit information to a train, which is needed for operating a train. In our system, The information including the allowable velocity of the train, train existence in current area, and other data necessary for operating train, is transmitted in the form of FM signal. Received by the receiver located on train, the signal is filtered, demodulated and analyzed to extract the original information. The analysis of the demodulated signal is done through FFT algorithm using sliding slot. These all are processed digitally by hardware which is implemented by 32bit DSP. The experiments show the validity of the algorithm we presented.

  • PDF

Development of Language Study Machine Using Voice Recognition Technology (음성인식 기술을 이용한 대화식 언어 학습기 개발)

  • Yoo, Jae-Tack;Yoon, Tae-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.201-203
    • /
    • 2005
  • The best method to study language is to talking with a native speaker. A voice recognition technology can be used to develope a language study machine. SD(Speaker dependant) and SI(speaker independant) voice recognition method is used for the language study machine. MP3 Player. FM Radio. Alarm clock functions are added to enhance the value of the product. The machine is designed with a DSP(Digital Signal Processing) chip for voice recognition. MP3 encoder/decoder chip. FM tumer and SD flash memory card. This paper deals with the application of SD ad SD voice recognition. flash memory file system. PC download function using USB ports, English conversation text function by the use of SD flash memory. LCD display control. MP3 encoding and decoding, etc. The study contents are saved in SD flash memory. This machine can be helpful from child to adult by changing the SD flash memory.

  • PDF

Correlation Algorithm for High-Precision Measurement in FM-CW Radar Level Meters (FM-CW 레이더 거리계의 비트 신호 스펙트럼 상관성을 이용한 고정밀 측정 알고리듬)

  • Kim, Jeong-Mok;Lim, Zong-Soo;Chun, Joong-Chang;Kim, Tae-Soo;Shim, Jae-Ryun;Park, Wee-Sang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.38-44
    • /
    • 2001
  • In this paper, for the microwave level meter based on the FM-CW radar, we analyze the spectrum correlation of beat signals and propose a measurement algorithm using the theory. For industrial applications, level meters must have high precision, which requires a good linearity of VCO. But, in practice, it is very complicated or very expensive to make VCO linear enough to be acceptable in the industrial field. We propose a measurement algorithm using the fact that there exists a peak in the spectrum correlation of beat signals when range difference is sufficiently small. This makes it possible to determine the range difference in a precise manner even using a practical VCO. We present some experimental results to show the validity of this algorithm.

  • PDF

Improving the Performance of the Capon Algorithm by Nulling Elements of an Inverse Covariance Matrix (공분산 역행렬 원소 제거 기법을 이용한 Capon 알고리듬의 성능 개선)

  • Kim, Seong-Min;Kang, Dong-Hoon;Lee, Yong-Wook;Nah, Sun-Phil;Oh, Wang-Rok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.5
    • /
    • pp.96-101
    • /
    • 2011
  • It is well known that the Capon algorithm offers better resolution compared to that of the FM (Fourier method) algorithm by minimizing the total output power while maintaining a constant gain in the look direction. Unfortunately, the DoA (Direction of Arrival) estimation performance of the Capon algorithm is drastically degraded when the SNR of received signal is low and thus, it cannot distinguish among signal sources which have similar incidence angles. In this paper, we propose a novel scheme enhancing the resolution of the Capon algorithm by ing all rows except the first row of an inverse covariance matrix.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

Heartbeat Detection based on Signal Reflected from Antenna in Mobile Device (휴대기기에서의 안테나 반사 신호를 이용한 심박 신호 검출)

  • An, Yong-Jun;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.643-649
    • /
    • 2013
  • In this paper, human heartbeat detection using signal reflected from the antenna which is varied reflection coefficient by near field variation of the antenna. For detection reflected signal from antenna, 20 dB directional coupler is used because of not affecting transmitting signal. Variance of reflection coefficient of dipole antenna is about 0.07 dB which is too small the distinction between heartbeat and noise. Sensitivity increasing method is applied and heartbeat is clearly detected. Due to phase and magnitude errors come from discrete value components, antenna is located some points in experiments ro find optimum sensitivity position. And providing verification of using communication signal, heartbeat detection when frequency modulated signal which have 4 MHz bandwidth is applied.

A Study on the Transmission Characteristics of 400MHz Signal in a Building (400MHz 대역 신호의 건물내 전달 특성에 관한 연구)

  • 차용성;강병권
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.17-20
    • /
    • 2001
  • In this paper, we realized a transceiver system for short distance communication with a commercial RF module working in ISM band. Also we measured system performance by transmitting baseband data in a building and then we compared the demodulated data bits with stored data bits in a PC connected with demodulator. The RF module In the experiments works only in the bandwidth of 424MHz-429MHz. The signal level degrades as the distance between transmitter and receiver increases. We measured the signal level and bit error and present the measured results with various locations in the building. And it is concluded that the measured data may be used in the design of short distance network in a building.

  • PDF

Improved Design of the Microwave Level Meter upon VCO Nonlinearity (마이크로파 거리계의 VCO 비선형성에 의한 시스템 특성 분석 및 개선 방안 연구)

  • 전중창;김정목임종수
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.331-334
    • /
    • 1998
  • In this paper, we have presented an improved design of the microwave level meter based on the principle of FM-CW radar. First, we have analyzed the effect of VCO nonlinearity on the spectral broadening of the beat signal, and presented a new type of design theory to linearize VCO tuning curve adopting FFT algorithm. Simulation results for a VCO having the linearity of 25% have been presented, which show the usefulness of the design algorithm.

  • PDF

Comparison of Computation Complexity for Digital Pulse Compressor (디지털 펄스압축기의 연산 양 비교)

  • 신현익;김상규;조태훈;김환우
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2196-2199
    • /
    • 2003
  • With the development of digital signal processor(DSP), digital pulse compressor (DPC) is commonly used in radar systems. A DPC is implemented by using finite impulse response(FIR) filter algorithm in time domain or fast Fourier transform(FFT) algorithm in frequency domain. This paper compares the computation complexity tot these two methods and calculates boundary Fm filter taps that determine which of the two methods is better based on computation amount. Also, it shows that the boundary FIR filter taps for DSP, ADSP21060, and those for computation complexity have similar characteristic.

  • PDF

Implementation of an RF Module for 2.4GHz Wireless Audio/Video Transmission (2.4GHz 무선 음성/영상 송신용 RF 모듈 구현)

  • 김거성;권덕기;박종태;유종근
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.55-58
    • /
    • 2002
  • This paper describes an RF module for 2.4GHz wireless audio/video transmission. The pre-processed baseband input signals are FM-modulated using a VCO and then transmitted through an antenna after RF filtering. The designed circuits are implemented using a Teflon board of which the size is 52mm${\times}$62mm. The measured maximum output signal levels are around -3dBm and the harmonics are less than -450dBc. The manufactured module consumes 130mA from a 8V supply.

  • PDF