• Title/Summary/Keyword: FLOW-THROUGH METHOD

Search Result 2,862, Processing Time 0.03 seconds

System-level Analysis of a Fan-motor Assembly for Vacuum Cleaner (진공청소기용 팬-모터 어셈블리의 시스템-레벨 분석)

  • Park, Chang-Hwan;Park, Kyung-Hyun;Chang, Kyung-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • A fan-motor assembly in a vacuum cleaner is analyzed through system-level analysis method. This system consisted of three components, a fan, motor, and the flow resistance of the motor, or of the vacuum cleaner. System-level analysis method is characterized by the combination of torque matching at a constant throttling condition between the fan and the motor and the pressure drop at a constant flow rate due to the flow resistance of the motor, or of the vacuum cleaner. The performance characteristics of the fan-motor assembly and the vacuum cleaner system could be predicted over the whole range of operation, based on the characteristics of each component. The predicted performance of the vacuum cleaner system through system-level analysis agreed well with the experimental results within 4.5% difference of pressure and 6% difference of the efficiency. The effect of flow resistance of a motor is investigated and it is found that the efficiency decrease of fan-motor assembly at the constant flow rate due to the flow resistance of a motor is determined by the flow resistance ratio(FRR), which is defined as a ratio of flow resistance of motor and the flow resistance of a constant throttling condition of a given point. The fan-motor assembly(S2 model) was modified to reduce the FRR from 9.0% to 2.4% and the experimental result shows that the efficiency of S2 model was improved by about 3% at best efficiency point.

Three Dimensional Unsteady Flow Characteristics inside the Catalytic Converter of 6 Cylinder Gasoline Engine (6기통 가솔린 엔진에 장착된 촉매변환기 내의 3차원 비정상 유동특성 해석)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.108-120
    • /
    • 1998
  • A theoretical study of three-dimensional unsteady compressible non-reacting flow inside double flow of monolith catalytic converter system attached to 6-cylinder engine was performed for the achievement of performance improvement, reduction of light-off time, and longer service life by improving the flow distribution of pulsating exhaust gases. The differences between unsteady and steady-state flow were evaluated through the numerical computations. To obtains the boundary conditions to a numerical analysis, one dimensional non-steady gas dynamic calculation was also performed by using the method of characteristics in intake and exhaust system. Studies indicate that unsteady representation is necessary because pulsation of gas velocity may affect gas flow uniformity within the monolith. The simulation results also show that the level of flow maldistribution in the monolith heavily depends on curvature and angles of separation streamline of mixing pipe that homogenizes the exhaust gas from individual cylinders. It is also found that on dual flow converter systems, there is severe interactions of each pulsating exhaust gas flow and the length of mixing pipe and junction geometry influence greatly on the degree of flow distribution.

  • PDF

A Study of Atmospheric-pressure Dielectric Barrier Discharge (DBD) Volume Plasma Jet Generation According to the Flow Rate (유량에 따른 대기압 유전체 전위장벽방전(DBD) 플라즈마 젯 발생에 관한 연구)

  • Byeong-Ho Jeong
    • Journal of Industrial Convergence
    • /
    • v.21 no.7
    • /
    • pp.83-92
    • /
    • 2023
  • The bullet shape of the plasma jet using the atmospheric-pressure dielectric barrier discharge method changes depending on the applied fluid rate and the intensity of the electric field. This changes appear as a difference in spectral distribution due to a difference in density of the DBD plasma jet. It is an important factor in utilizing the plasma device that difference between the occurrence of active species and the intensity through the analysis of the spectrum of the generated plasma jet. In this paper, a plasma jet generator of the atmospheric pressure volume DBD method using Ar gas was make a prototype in accordance with the proposed design method. The characteristics jet fluid rate analysis of Ar gas was accomplished through simulation to determine the dependence of flow rate for the generation of plasma jets, and the characteristics of plasma jets using spectrometers were analyzed in the prototype system to generate optimal plasma jet bullet shapes through MFC flow control. Through the design method of the proposed system, the method of establishing the optimal plasma jet characteristics in the device and the results of active species on the EOS were verified.

Thw Characteristic of Supersonic Flow with Condensation along a Wavy Wall of Small Amplitute in Channel (미소진폭 파형벽을 가진 유로내에서 凝縮을 수반하는 超音速 유동의 特性 - 수치해석 결과)

  • 김병지;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1990-1997
    • /
    • 1992
  • The characteristic of supersonic flow with condensation along a wavy wall of small amplitude in channel is investigated through the direct marching method of characteristics. The very complex problem that may appear where the overlapping of the same family characteristics occurs, can be satisfactorily solved by means of the modified method suggested by Zucrow. In the present study for the case of supersonic moist air flow, the dependency of location of formation and reflection of oblique shock wave generated by the wavy wall, and the distributions of flow properties, on the relative humidity and temperature at the entrance of wavy wall is clarified by plots of streamline, ios-Mach umber and ios-flow properties. Also, it is confirmed that the wavy wall plays an important key role in the formation of oblique shock wave, and that the effect of condensation on the flow field appears apparently.

Analysis of Compressible Flow Fields in a High Voltage Gas Circuit Breaker (초고압 가스차단기 내부의 압축성 유동장 해석)

  • Lee, J.C.;Oh, I.S.;Kim, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.305-310
    • /
    • 2001
  • This paper presents the computational method for analyzing the compressible flow fields in a high voltage gas circuit breaker. There are many difficult problems in analyzing the gas flow in GCB due to complex geometry, moving boundary, shock wave and so on. In particular, the distortion problem of the grid due to the movement of moving parts can be worked out by the fixed grid technique. Numerical simulations are based on a fully implicit finite volume method of the compressible Reynolds-averaged Navier-Stokes equations to obtain the pressure, density, and velocity through the entire interruption process. The presented method is applied to the real circuit breaker model and the pressure in front of the piston is good agreement with the experimental one.

  • PDF

Numerical Analysis of Unsteady Viscous Flow Through a Weis-Fogh Type Ship Propulsion Mechanism Using the Advanced Vortex Method

  • Ro Ki-Deok;Kang Myeong-Hun;Kong Tae-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.769-778
    • /
    • 2005
  • The velocity and pressure fields of a ship's Weis-Fogh type propulsion mechanism are studied in this paper using an advanced vortex method. The wing (NACA0010 airfoil) and channel are approximated by source and vortex panels. and free vortices are introduced away from the body surfaces. The viscous diffusion of fluid is represented using the core-spreading model to the discrete vortices. The velocity is calculated on the basis of the generalized Biot-Savart law and the pressure field is calculated from an integral, based on the instantaneous velocity and vorticity distributions in the flow field. Two-dimensional unsteady viscous flow calculations of this propulsion mechanism are shown. and the calculated results agree qualitatively with the measured thrust and drag due to un-modeled large fluctuations in the measured data.

A Time-Derivative Preconditioning Method for Compressible Flows at All Speeds (Preconditioning을 이용한 전속도 영역에 대한 압축성 유체유동해석)

  • 최윤호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1840-1850
    • /
    • 1994
  • Enhancement of numerical algorithms for low speed compressible flow will be considered. Contemporary time-marching algorithm has been widely accepted and applied as the method of choice for transonic, supersonic and hypersonic flows. In the low Mach number regime, time-marching algorithms do not fare as well. When the velocity is small, eigenvalues of the system of compressible equations differ widely so that the system becomes very stiff and the convergence becomes very slow. This characteristic can lead to difficulties in computations of many practical engineering problems. In the present approach, the time-derivative preconditioning method will be used to control the eigenvalue stiffness and to extend computational capabilities over a wide range of flow conditions (from very low Mach number to supersonic flow). Computational capabilities of the above algorithm will be demonstrated through computation of a variety of practical engineering problems.

An approach for the functional extension of the remote measurement method of unsteady flow rate

  • Yokota, Shin-ichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.235-239
    • /
    • 1992
  • The paper describes an approach for estimating unsteady flow rate through oil hydraulic pipelines and components in real time. Recently we have proposed following three unsteady flow rate measurement approaches; RIFM, QIFM and TPFM, in which hydraulic pipeline dynamics are made use of. In this paper, we firstly propose new approaches, i.e, an interpolation and an extrapolation methods in combination with RIFM and TPFM. In the interpolation method, unsteady flow rate at the arbitrary internal location along the pipeline between two points for measuring the two point pressure can be estimated. In this paper, the accuracy and dynamic response of interpolation method are mainly experimentally investigated in detail.

  • PDF

Review Methods of Pumping Effciency using the Concrete flow Table Test (콘크리트 플로 테이블 테스트를 활용한 압송성 검토 방법)

  • Kwon, Hae-Won;Gong, Min-Ho;Kim, Bong-Sup;Yu, Jong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.9-10
    • /
    • 2016
  • This study is purposed to review the confirm method of pumping efficiency using the concrete flow table test in Korea environment. This test method is registered as the "EN 12350-5, Testing fresh concrete. Flow table test" in Eurocode. When applying this test in the Korea construction environment, we reviewed that reasonably apply on the Korean construction Environment. As a result, test results analysis showed that the reality looks a big difference. Its cause is believed to be due to the shape of coarse & fine aggregate. But it will be better predict method, through the correlation analysis of construction data and the standard(Placing Concrete by pumping Methods(ACI Manual of concrete Practice 304.2R-96)).

  • PDF

Aerodynamic Design of the Axial Fan (축류 송풍기의 공력학적 설계)

  • Sohn, Sang-Bum;Joo, Won-Gu;Cho, Kang-Rae;Nam, Hyung-Baik;Yoon, In-Kyu;Nam, Leem-Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.22-28
    • /
    • 1999
  • In this study, a preliminary design method of the axial fan was systematically established based on the two-dimensional cascade theory. Flow deviation, lift coefficient, distribution of velocity and pressure coefficient on blade surfaces were predicted by an inviscid flow theory of Martensen method, which was also applied to select an airfoil for required performance in the present design process. The aerodynamic performance of designed blades can be predicted quickly and reasonably by using the through-flow calculation method in the preliminary design process. It would be recommendable to adopt three-dimensional viscous flow calculation at the final design refinement stage.

  • PDF