• 제목/요약/키워드: FLEX

검색결과 446건 처리시간 0.02초

OrcaFlex를 이용한 심해 SCR 구조 해석 (Structural Analysis of Deepwater Steel Catenary Riser using OrcaFlex)

  • 박규식;최한석;김도균;유수영;강수창
    • 한국해양공학회지
    • /
    • 제29권1호
    • /
    • pp.16-27
    • /
    • 2015
  • The design challenges when attempting to obtain sufficient strength for a deepwater steel catenary riser (SCR) include high stress near the hang-off location, an elevated beam-column buckling load due to the effective compression in the touchdown zone (TDZ), and increased stress and low-cycle fatigue damage in the TDZ. Therefore, a systematic strength analysis is required for the proper design of an SCR. However, deepwater SCR analysis is a new research area. Thus, the objective of this study was to develop an overall analysis procedure for a deepwater SCR. The structural behavior of a deepwater SCR under various environmental loading conditions was investigated, and a sensitivity analysis was conducted with respect to various parameters such as the SCR weight, weight of the internal contents, hang-off angle (HOA), and vertical soil stiffness. Based on a deepwater SCR design example, it was found that the maximum stress of an SCR occurred at a hang-off location under parallel loading direction with respect to the riser plane, except for a wave dominant dynamic survival loading condition. Furthermore, the tensile stress governed the total stress of the SCRs, whereas the bending stress governed the total stress at the TDZ. The weight of the SCR and internal contents affected the maximum stress of the SCR more than the HOA and vertical soil stiffness, because the weight of the SCR, including the internal contents, was directly related to its tensile stress.

굽힘 센서신호를 이용한 인공의수의 제어 (Control of an Artificial Arm using Flex Sensor Signal)

  • 유재명;김영탁
    • 한국지능시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.738-743
    • /
    • 2007
  • 본 연구는, 팔(하완)을 잃은 장애자용 인공 의수를 장애자가 자신의 의도에 따라 제어하기 위한 센서 시스템과 제어알고리즘에 관한 것이다. 먼저 장애자의 여러 가지 동작 의도를 검출할 수 있는 센싱 시스템을 연구하고 이 센싱 시스템으로부터 발생된 신호를 사용하여 인공의수를 제어하는 방법에 대하여 연구한다. 센서로서는 전기 저항식 굽힘 센서를 사용한다. 이 굽힘 센서를 팔의 상완 이두근과 오구완근에 각각 1개씩 단단히 부착한다. 부착된 센서로부터 출력된 신호는 근육의 굴곡량을 나타내며 팔의 동작의도를 판단 할 수 있는 신호처리 시스템을 통과시켜 하완의 굴곡과 신전 운동, 손의 내전과 외전 운동을 구별한다. 그리고 구별된 신호로부터 실제 팔의 운동 각도를 추정하여 인공의수의 각도를 제어한다. 본 연구의 효용성을 증명하기 위해 2개의 액추에이터와 포텐셔미터를 가진 간단한 인공의수를 제작하여 제어 실험을 하였다. 실험에서 실제 팔의 각도와 인공의수의 제어 각도 사이에는 센서 외부에서 발생되는 노이즈 및 인공의수의 회전 관성, 기계적인 마찰 등으로 인한 오차가 발생하였다. 따라서 오차 값과 오차의 변화 값에 근거한 퍼지 제어 알고리듬을 이용하여 재 실험을 한 결과 하완의 굴곡/신전 운동에서는 평균 약 4도, 손의 회내/외 운동에서는 평균 약 3도의 오차가 측정되어, 퍼지제어기를 설치한 이전보다 오차가 크게 개선되었다.

RIA기반의 웹 콘텐츠 관리에 관한 설계 및 구현 (Design and Implementation of Web Contents Management System based on RIA)

  • 서준오;김철원
    • 한국전자통신학회논문지
    • /
    • 제10권10호
    • /
    • pp.1109-1114
    • /
    • 2015
  • 본 논문은 RIA 기술 중 하나인 어도비 플렉스 프레임워크를 기반으로 하는 CMS를 설계 구현 한다. 플렉스는 기존 HTML+CSS+Javascript 등으로 이루어진 마크업 언어 위에 다양한 시각적 컴포넌트를 쉽게 추가 할 수 있어 보다 역동적인 웹사이트를 구현할 수 있게 해준다. HTTP요청 처리는 MVC기반의 스프링 프레임워크를 사용한다. 스프링 프레임워크는 자바 플랫폼을 위한 오픈소스 프레임워크로 동적인 웹 사이트를 개발하기 위한 여러 가지 서비스를 제공하고 있으며, 대한민국 공공기관의 웹 서비스 개발 시 사용을 권장하고 있는 전자정부 표준프레임워크의 기반 기술로 쓰이고 있다. 갈수록 방대해져 가는 웹 콘텐츠들을 보다 효율적으로 생산 관리하는 방법을 제시한다.

팔목 부착형 생체신호 측정기기에 사용가능한 방사패턴 재구성 안테나 설계 및 인체 SAR 영향 분석 (Design of Radiation Pattern Reconfigurable Antenna for Vital Signal Sensing Device Attached on Wristband and SAR Analysis on Human body)

  • 이창민;정창원
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.666-670
    • /
    • 2015
  • 본 논문은 생체신호를 측정하는 팔목부착용 Fitbit Flex상에 구현된 방사패턴 재구성 안테나에 관련된 논문이다. 또한 본 논문에서 제안하는 루프-다이폴 방사패턴 재구성 안테나의 인체 내 부위별 전자파 흡수율 (Specific Absorption Rate; SAR)에 관한 논문이다. 본 논문의 루프-다이폴 방사패턴 재구성 안테나는 두 개의 RF 스위치를 사용하여 서로 반대방향의 두 가지 방사패턴을 구현한다. 방사패턴 재구성 안테나는 블루투스 (Bluetooth) 통신 대역 (2.4 - 2.485 GHz)을 사용하며, 최대이득은 1.96 dBi이다. SAR 시뮬레이션 결과로 블루투스 입력 평균전력 0.04 W가 팔목을 포함하는 인체 내 다섯 개 부위 (두부, 가슴, 배, 등, 팔목)에 입력되었을 때 Federal Communication Commission (FCC)의 기준인 단위 1 g 당 1.6 W/kg을 모두 만족함을 확인하였다. 또한 최대 SAR 값은 두부에서 1.12 W/kg이다.

Low Magnetic Field MRI Visibility of Rubber-Based Markers

  • Kim, Jeong Ho;Jung, Seongmoon;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.89-93
    • /
    • 2019
  • Purpose: This study aims to develop new markers based on silicone rubber and urethane rubber to enhance visibility in low magnetic field magnetic resonance (MR) imaging. Methods: Four types of markers were fabricated using two different base materials. Two of the markers were composed of two different types of silicone rubber: DragonSkin™ 10 MEDIUM and BodyDouble™ SILK. The other two markers were composed of types of urethane rubber: PMC™ 780 DRY and VytaFlex™ 20. Silicone oil (KF-96 1000cs) was added to the fabricated markers. The allocated amount of oil was 20% of the weight (wt%) of each respective marker. The MR images of the markers, with and without the silicone oil, were acquired using MRIdian with a low magnetic field of 0.35 T. The signal intensities of each MR image for the markers were analyzed using ImageJ software and the visibility for each was compared. Results: The highest signal intensity was observed in VytaFlex™ 20 (279.67±3.57). Large differences in the signal intensities (e.g., 627% in relative difference between BodyDouble™ SILK and VytaFlex™ 20) among the markers were observed. However, the maximum difference between the signal intensities of the markers with the silicone oil showed only a 62% relative difference between PMC™ 780 DRY and DragonSkin™ 10 MEDIUM. An increase in the signal intensity of the markers with the silicone oil was observed in all markers. Conclusions: New markers were successfully fabricated. Among the markers, DragonSkin™ 10 MEDIUM with silicone oil showed the highest MR signal intensity.

고속 페이징 시스템을 위한 FLEX 프로토콜 신호처리기의 구현 (Implementation of a FLEX Protocol Signal Processor for High Speed Paging System)

  • 강민섭;이태응
    • 대한전자공학회논문지SD
    • /
    • 제38권1호
    • /
    • pp.69-78
    • /
    • 2001
  • 본 논문은 휴대용 고속 페이징 시스템을 위한 FLEXTM 프로토콜 신호 처리기의 설계 및 FPGA 구현에 관한 것이다. 본 논문에서는 A/D 변환기의 입력 단에서 수신된 interleaved 4-level 비트 심볼 데이터의 동기를 위한 심볼 동기 알고리듬과 (31,21)BCH 부호에 대해 실시간 2중 오류정정이 가능한 개선된 복호 알고리듬을 제안한다. 설계된 프로토콜 신호처리기는 6개의 기능 모듈로 구성되어 있으며, 각 모듈은 VHDL(VHSIC Hardware Description Language)로 모델링을 행하였다. 제안된 프로토콜 신호기는 Axil-320 워크스테이션 상에서 Synopsys/sup TM/툴을 이용하여 기능 시뮬레이션 및 논리합성(Altera 10K 라이브러리 이용)을 수행하였다. 논리합성 결과 전체 셀의 수는 약 2,631이었다 또한, 설계된 FPGA 칩의 설계검증을 위하여 Altera MAX+ PLUS Ⅱ 상에서 타이밍 시뮬레이션을 수행하였다. PCB 상에서 testbed를 구축한 후, Logic Analyzer를 이용하여 제작된 FPGA 칩의 동작상태를 확인하였고, 실험을 통하여 제작된 칩이 정확히 동작함을 확인하였다.

  • PDF

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

세 종류의 Stainless Steel File을 이용한 만곡근관 형성 후 근관형태 변화에 관한 비교 연구 (A Comparison of Three Stainless Steel Instruments in the Preparation of Curved Root Canals in vitro)

  • Young-Tae Kim;Seung-Ho Baek;Kwang-Sik Bae;Sung-Sam Lim;Soo-Han Yoon
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.9-15
    • /
    • 2001
  • 통상적인 근관형성 과정에서 근관형태의 직선화 경향을 발견할 수 있으며, 그 결과 만곡이 심한 근관에서 이상적인 근관형태를 얻기가 어렵다. 이를 극복하기 위한 많은 기구들과 근관 성형법들이 개선되고 소개되었다. 본 연구에서는 최근에 개발된 직사각형의 단면을 가지는 stainless steel file인 RT file과 Flex-R file, K-file을 이용하여 만곡근관 형성 후 최종 근관형태를 비교하여 각 file을 평가하고자 한다. 본 실험은 Bramante등의 방법을 변형하여 술 전의 근관형태와 술 후의 근관형태를 비교하였다. Schneider의 방법을 변형하여 3차원적 만곡을 계산하여 12도에서 36도 이내에 만곡도를 가진 근관을 선택하였다. 49개의 발거된 상악대구치 협측근관이나 하악대구치 근심근관을 3개의 군으로 나누고 레진과 플라스틱으로 제작된 mold에 투명한 교정용 레진으로 매몰하였다. 근첨에서 2.5, 5, 8mm지점에서 절단하여 각 mold에서 재조립한 후 다음과 같이 근관형성을 시행하였다. 제 1군은 SS K-file을 이용하여 step-back 방법 ; 제 2군은 Flex-R file을 이용하여 balanced force 방법 ; 제 3군은 RT file을 이용하여 step-back 방법으로 근관 형성하였다. 술 전과 술 후에 각 시편들을 체현미경으로 사진촬영하여 근관 중심 위치 이동률, 근관형성으로 삭제된 상아질양, 근관형성 후 모양을 Sigma scan/ image software program으로 계산하고 One way ANOVA로 통계적 유의성을 검증하여 다음과 같은 결론을 얻었다. 1. RT file이 치근단에서 K-file보다 유의성 있게 근관의 중심을 유지하는 것으로 보였다. 치아 중앙부에서는 RT file과 Flex-R file이 K-file에 대해 유의성 있게 우수한 것으로 나타났다. 2. 근관형성 후 삭제된 상아질양에서는 치근단에서 RT file이 적게 나왔으나 유의성은 없었다. 3. 근관형성 후 절단면 모양은 원형, 타원형, 불규칙한 형태들이 다양하게 나타났고 각 군간에 유의성 있는 차이는 없었다.

  • PDF

3D 프린팅 기법을 이용한 하모닉 드라이브(Harmonic Drive) 설계 및 응용 분석 (Design of a Novel 3D Printed Harmonic Drive and Analysis of its Application)

  • 김상현;변창섭;이철희
    • Tribology and Lubricants
    • /
    • 제38권1호
    • /
    • pp.27-31
    • /
    • 2022
  • Harmonic drives have attracted increasing attention with the development of materials, parts, and related equipment. Harmonic drives exhibit high deceleration, high accuracy, and light weight. The stiffness of flexible splines according to the radial load is studied using a commercial FEM program to design the structure of the flexible spline and finite element to improve the weight and price competitiveness of harmonic drives. In addition, several studies have measured and compared friction coefficients based on 3D printed tread patterns. However, owing to the characteristics of plastic materials, a decrease in stiffness in the radial direction is inevitable. To prevent a decrease in stiffness in the radial direction, we designed and manufactured flex splines with a wrinkle shape. Through structural analysis, the reaction force and stiffness in the radial direction were determined. In addition, the maximum angle of the mound was derived by theoretical calculations, and the performance of the harmonic drive was compared with the results obtained in the mound experiment. Structural analysis shows that the shape of wrinkles decreased the stress and reaction force and increased the safety factor in comparison with that of the circular shape. During performance verification through continuous experiments, the developed harmonic drive showed continuous performance similar to that of an actual tank model. It is expected that the flex spline with a compliant spring and wrinkle shape will prevent a decrease in the radial stiffness.

Influence of access cavity design on calcium hydroxide removal using different cleaning protocols: a confocal laser scanning microscopy study

  • Seda Falakaloglu;Merve Yeniceri Ozata;Betul Gunes;Emmanuel Joao Nogueira Leal Silva;Mustafa Gundogar;Burcu Gucyetmez Topal
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.25.1-25.13
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of endodontic access cavities design on the removal of calcium hydroxide medication of the apical third of mandibular incisor root canal walls and dentinal tubules with different cleaning protocols: EDDY sonic activation, Er,Cr:YSGG laser-activated irrigation, or conventional irrigation with IrriFlex. Materials and Methods: Seventy-eight extracted human mandibular incisors were assigned to 6 experimental groups (n = 13) according to the endodontic access cavity and cleaning protocol for calcium hydroxide removal: traditional access cavity (TradAC)/EDDY; ultraconservative access cavity performed in the incisal edge (UltraAC.Inc)/EDDY; TradAC/Er,Cr:YSGG; UltraAC. Inc/Er,Cr:YSGG; TradAC/IrriFlex; or UltraAC.Inc/IrriFlex. Confocal laser scanning microscopy images were used to measure the non-penetration percentage, maximum residual calcium hydroxide penetration depth, and penetration area at 2 and 4 mm from the apex. Data were statistically analyzed using Shapiro-Wilk and WRS2 package for 2-way comparison of non-normally distributed parameters (depth of penetration, area of penetration, and percentage of non-penetration) according to cavity and cleaning protocol with the significance level set at 5%. Results: The effect of cavity and cleaning protocol interactions on penetration depth, penetration area and non-penetration percentage was not found statistically significant at 2 and 4 mm levels (p > 0.05). Conclusions: The present study demonstrated that TradAC or UltraAC.Inc preparations with different cleaning protocols in extracted mandibular incisors did not influence the remaining calcium hydroxide at 2 and 4 mm from the apex.