• Title/Summary/Keyword: FLEX

Search Result 448, Processing Time 0.029 seconds

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

Characteristics of Air Quality in the West Coastal Urban Atmosphere; Characteristics of VOCs Concentration Measured from an Industrial Complex Monitoring Station at Gunsan and a Roadside Station at Jeonju (서해연안 도시지역의 대기질 특성 연구: 군산시 산업단지와 전주시 도로변에서 VOCs 농도분포 특성 연구)

  • Ryoo, Jae-Youn;Kim, Deug-Soo;Chae, Soo-Cheon;Nam, Tu-Cheon;Choi, Yang-Seock
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.633-648
    • /
    • 2010
  • The study was performed to elucidate the characteristics of VOCs at distinct monitoring sites in urban atmosphere; one is at a roadside in downtown inland city of Jeonju, and the other is at an industrial site in Gunsan near coastal area. The ambient samples were collected for 24 hours in two-bed adsorbent tubes by using MTS-32 sequential tube sampler equipped with Flex air pump every 16 days in a roadside and a industrial complex from February to November in 2009. VOCs were determined by thermal desorption coupled with GC/MSD. Major individual VOCs in roadside samples were shown as following order in magnitude: toluene>m,p-xylene>ethyl benzene>decanal; and those in the industrial complex samples were as follows: toluene>ethanol>ethyl acetate>decanal>m,pxylene. High benzene concentration in the roadside was more frequently occurred than in the industrial complex. However ambient level of toluene in the industrial complex was higher than that in the road side. Results from roadside sample analysis showed that nonane and 1,2,4-trimethylbenzene were very frequently observed with higher concentrations than those in the industrial complex. It seems that nonane and 1,2,4-trimethylbenzene could be the source characteristics for the roadside air. From the diurnal variation, it was found that concentrations of benzene, ethylbenzene, xylene, nonane and 1,2,4-trimethylbenznene in the roadside were higher during rush hours; but those in the industrial complex were higher from 10 to 16 LST when the industrial activities were animated. On weekly base, the concentration of benzene, toluene, ethylbenzene and m,p-xylene in the roadside were higher specifically on Wednesday, but those in the industrial complex were higher on Sunday. It was found that the general trends of VOCs levels at both sites significantly influence on seasonal changes. The results of factor analysis showed that the VOCs in the roadside were mainly affected by the emission of vehicles and the evaporation of diesel fuel, meanwhile those in the industrial complex were influenced by the evaporation of solvents and vehicular emission.

Isokinetic Evaluation of Plantarflexors with Knee Position (슬관절의 자세에 따른 족관절 저측굴곡근의 등속성 근력 평가)

  • Bae Sung-Soo;Lee Hyun-Ok;Lee Keun-Heui
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.145-152
    • /
    • 2000
  • Pcak torque. angle of peak torque occurrence. total work, average power. endurance of the ankle plantar flexors were studied with the knee positioned $0^{\circ}\;and\;90^{\circ}$ flexion. Plantar flexors of 20 students were tested on Cybex 6000 dynamometer. The results were as fallows ; 1. The peak torque values were significantly higher with knee extension than knee $90^{\circ}$ flexion. 2. The angle of peak torque occurrence were earlier with knee extension than knee $90^{\circ}$ flexion, but no significant. 3. The total work were significantly higher with knee extension than knee $90^{\circ}$ flexion. at$30^{\circ}/sec$, but no significant at $90^{\circ}/sec$ 4. The endurance ratio were higher significantly with knee $90^{\circ}$ flex ion than knee extension 5. The mean average power were significantly higher with knee extension than knee $90^{\circ}$ flextion

  • PDF

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

3-D Kinematic comparison of One Hand Backhand Stroke and Two Hand Backhand Stroke in Tennis (테니스 한손 백핸드 스트로크와 양손 백핸드 스트로크 동작의 3차원 운동학적 비교 분석)

  • Choi, Ji-Young;Shin, Je-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.85-95
    • /
    • 2005
  • The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle during One Hand Backhand Stroke and Two Hand Backhand in tennis. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and racket head direction were defined. 1. In three dimensional maximum linear velocity of racket head the X axis and Y axis(horizontal direction) showed $-11.04{\pm}2.69m/sec$, $-9.31{\pm}0.49m/sec$ before impact, the z axis(vertical direction) maximum linear velocity of racket head did not show at impact but after impact this will resulted influence upon hitting ball. It could be suggest that Y axis velocity of racket head influence on ball direction and z axis velocity influence on ball spin after impact. The stance distance between right foot and left foot was mean $75.4{\pm}5.86cm$ during one hand backhand stroke and $72.6{\pm}4.67cm$ during two hand backhand stroke. 2. The three dimensional anatomical angular displacement of trunk in interna rotation-external rotation showed most important role in backhand stroke. and is follwed by flexion-extension. the three dimensional anatomical angular displacement of trunk did not show significant difference between one hand backhand stroke and two hand backhand stroke but the three dimensional anatomical angular displacement of trunk was bigger than one hand backhand stroke. 3. while backhand stroke, the flexion-extension and adduction-abduction of right shoulder joint showed significant different between one hand backhand stroke and two hand backhand stroke. the three dimensional anatomical angular displacement of right shoulder joint showed more flex and abduct in one hand backhand stroke. 4. The three dimensional anatomical angular displacement of left shoulder showed flexion, adduction, and external rotation at impact. after impact, The angular displacement as adduction-abduction of left shoulder changed motion direction as abduction. angular displacement of left shoulder as flexion-extension showed bigger than the right shoulder.

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF

Biomechanical Analysis of a Combined Interspinous Spacer with a Posterior Lumbar Fusion with Pedicle Screws (척추경나사못을 이용한 유합술과 동반 시술된 극돌기간 삽입기구의 생체역학적 연구)

  • Kim, Y.H.;Park, E.Y.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Recently, during the multi-level fusion with pedicle screws, interspinous spacer are sometimes substituted for the most superior level of the fusion in an attempt to reduce the number of fusion level and likelihood of degeneration process at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the interspinous spacer combined with posterior lumbar fusion with a previously-validated 3-dimensional FE model of the intact lumbar spine (L1-S1). The post-operative models were made by modifying the intact model to simulate the implantation of interspinous spacer and pedicle screws at the L3-4 and L4-5. Four different configurations of the post-op model were considered: (1) a normal spinal model; (2) Type 1, one-level fusion using posterior pedicle screws at the L4-5; (3) Type 2, two-level (L3-5) fusion; (4) Type 3, Type 1 plus Coflex$^{TM}$ at the L3-4. hybrid protocol (intact: 10 Nm) with a compressive follower load of 400N were used to flex, extend, axially rotate and laterally bend the FE model. As compared to the intact model, Type 2 showed the greatest increase in Range of motion (ROM) at the adjacent level (L2-3), followed Type 3, and Type 1 depending on the loading type. At L3-4, ROM of Type 2 was reduced by 34~56% regardless of loading mode, as compared to decrease of 55% in Type 3 only in extension. In case of normal bone strength model (Type 3_Normal), PVMS at the process and the pedicle remained less than 20% of their yield strengths regardless of loading, except in extension (about 35%). However, for the osteoporotic model (Type 3_Osteoporotic), it reached up to 56% in extension indicating increased susceptibility to fracture. This study suggested that substitution of the superior level fusion with the interspinous spacer in multi-level fusion may be able to offer similar biomechanical outcome and stability while reducing likelihood of adjacent level degeneration.

Early Life History of the Red Marbled Rockfish, Sebastiscus tertius (Barsukov et Chen) 1. Egg Morphology and Development of Larvae and Juveniles (붉은쏨뱅이, Sebastiscus tertius (Barsukov et Chen)의 초기생활사 1. 난의 형태 및 산출 자치어의 성장에 따른 형태발달)

  • 김광수;임상구;한경호;오성현;노병율
    • Journal of Aquaculture
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 1999
  • From January 1997 to May, the red marbled rockfish, Sebastiscus tertius (Barsukov et Chen) was reared in the laboratory, and observed the morphological characteristies of egg and development of larvae and juveniles. The egg is spherical in shape colorless and transparent, measuring 0.72~0.80mm in diameter (mean 0.75mm, n=50). The naturally bearing larvae were 3.79~3.97mm in total length with 7~8+15~16=22~24 myomeres, and mouth and anus were open. Melanophores were present on the yolk of the larva and ventral margins of the tail. The 1~2 days after bearing larvae measured 3.90~4.13mm in total length, and transformed to postlarval stage, and yolk sac were completely resorbed. On the lower jaw melanophores were present. Total length of the larvae was 4.23~4.60mm in total length (11 days after bearing), number of elongated pectoral fin rays was 9~10, and melanophores distributed on the top of head, around the intestine tube, ventral margins of the tail and on the pectoral fin. In 21 days after bearing, the larva were 5.83~7.10mm in total length, and the caudal notochord flex $45^{\circ}$. Individuals of 9.80~12.36mm in total length (33 days after bearing) are regarded to have reached to the juvenile stage with all the fins were developed.

  • PDF

A Study on Creep Effect of Synthetic Fiber Rope Mooring System on Motion Response of Vessel and Tension of Mooring Line (섬유로프 계류시스템의 크리프 효과가 부유체의 운동응답 및 계류선의 장력 변화에 미치는 영향에 관한 연구)

  • Park, Sung Min;Lee, Seung Jae;Kang, Soo Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.151-160
    • /
    • 2017
  • Growing demand and rapid development of the synthetic fiber rope in mooring system have taken place since it has been used in deep water platform lately. Unlike a chain mooring, synthetic fiber rope composed of lightweight materials such as Polyester(polyethylene terephthalate), HMPE(high modulus polyethylene) and Aramid(aromatic polyamide). Non-linear stiffness and another failure mode are distinct characteristics of synthetic fiber rope when compared to mooring chain. When these ropes are exposed to environmental load for a long time, the length of rope will be increased permanently. This is called 'the creep phenomenon'. Due to the phenomenon, The initial characteristics of mooring systems would be changed because the length and stiffness of the rope have been changed as time goes on. The changed characteristics of fiber rope cause different mooring tension and vessel offset compared to the initial design condition. Commercial mooring analysis software that widely used in industries is unable to take into account this phenomenon automatically. Even though the American Petroleum Institute (API) or other classification rules present some standard or criteria with respect to length and stiffness of a mooring line, simulation guide considers the mechanical properties that is not mentioned in such rules. In this paper, the effect of creep phenomenon in the fiber rope mooring system under specific environment condition is investigated. Desiged mooring system for a Mobile Offshore Drilling Unit(MODU) with HMPE rope which has the highest creep is analyzed in a time domain in order to investigate the effects creep phenomenon to vessel offset and mooring tension. We have developed a new procedure to an analysis of mooring system reflecting the creep phenomenon and it is validated through a time domain simulation using non-linear mooring analysis software, OrcaFlex. The result shows that the creep phenomenon should be considered in analysis procedure because it affects the length and stiffness of synthetic fiber rope in case of high water temperature and permanent mooring system.

Vegetation and flora of Hibiscus hamabo inhabited naturally in Soan Island

  • Ahn, Young-Hee;Chung, Kyu-Hwan;Park, Hee-Seung
    • Journal of Environmental Science International
    • /
    • v.12 no.11
    • /
    • pp.1181-1187
    • /
    • 2003
  • Hibiscus hamabo, called "Hwang-geun", growing about 3m in height is a deciduous shrub or subtree of Malvaceae. Because the number of these species is very limited in the world, the Ministry of Environment has designated H. hamabo as a preserved plant. The Korea Forest Service also protects it strictly by law since H. hamabo is an out-of-the-way plant and possibly may be exterminated soon in Korea. Investigation for distribution and ecological characteristics of the habitat for H. hamabo was carried out on Soan Island. Two wild H. hamabo were found at the forest edge (equation omitted) along the sea coast located in the southern part of Soan Island and this was the first report in the Korean academic world. These two wild H. hamabos were growing in a naturally inhibited area. The diameters at the base were 12cm and 15cm. The Tree heights were 150cm and 210cm and the number of branches of each wild H. hamabo was 4 and 7. However, the present condition of these plants was not good. Environmental conditions of the naturally inhibited area of H. hamabo were very mild because it is located at the edge of the forest and is always sunny during the daytime since the slope of the inhibited area is facing South. The ground drained very well since the soil was made of gravels and sand. Because the percent of vegetation of the subtree layer where H. hamabo was growing was 40%, the cover degree and sociability of flex crenata trees and Eurya japonica were found to be high. In the naturally inhibited area of H. hamabo, a dominant value of Rubus parvifolius in the lower part of the herb layer was very high and many plants in Compositae, such as Artemisia princeps var. orientalis and Erigeron annuus, were also present. A dominant value of liana, such as Vitis thunbergii var. sinuata, Rosa multiflora, Clematis terniflora and Hedera rhombea, and Gramineae plants that rhizomes were well developed and aggressively propagated, such as Miscanthus sinensis var. purpurascens, Phragmites communis, Spodiopogon cotulifer and Oplismenus undulatifolius which were surveyed as high, too. These results imply that H. hamabo might be exterminated soon through a natural selection if the proper management of the naturally inhibited area of H. hamabo is not conducted continually.