• 제목/요약/키워드: FLASH radiotherapy

검색결과 5건 처리시간 0.02초

Electron beam scattering device for FLASH preclinical studies with 6-MeV LINAC

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Hee Chang;Lee, Kyohyun;Kim, Seung Heon;Lee, Dong Eun;Jang, Kyoung Won
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1289-1296
    • /
    • 2021
  • In this study, an electron-scattering device was fabricated to practically use the ultra-high dose rate electron beams for the FLASH preclinical research in Dongnam Institute of Radiological and Medical Sciences. The Dongnam Institute of Radiological and Medical Sciences has been involved in the investigation of linear accelerators for preclinical research and has recently implemented FLASH electron beams. To determine the geometry of the scattering device for the FLASH preclinical research with a 6-MeV linear accelerator, the Monte Carlo N-particle transport code was exploited. By employing the fabricated scattering device, the off-axis and depth dose distributions were measured with radiochromic films. The generated mean energy of electron beams via the scattering device was 4.3 MeV, and the symmetry and flatness of the off-axis dose distribution were 0.11% and 2.33%, respectively. Finally, the doses per pulse were obtained as a function of the source to surface distance (SSD); the measured dose per pulse varied from 4.0 to 0.2 Gy/pulse at an SSD range of 20-90 cm. At an SSD of 30 cm with a 100-Hz repetition rate, the dose rate was 180 Gy/s, which is sufficient for the preclinical FLASH studies.

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구 (A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging)

  • 윤성익;권수일;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.105-113
    • /
    • 1998
  • 고에너지 광자선을 발생시키는 의료용선형가속기의 선질은 경우에 따라 변이를 가져오게 된다. 이러한 변이를 정확하게 판정하여 줄 수 있는 방사선측정법의 활용은 매우 중요하다. 보편적으로 광자선의 측정에 있어서 전리함의 사용이 아주 빈번하였으나 전자포탈영상장치(EPID)의 등장은 새로운 방사선측정법에 대한 가능성의 시작을 예견해준다. 실험은 6MV 광자선의 대칭성, Light/Radiation congruence, 그리고 Wedge filter를 통한 간편한 에너지의 변화에측과 위치의 정확도에 대하여 측정을 시행하였다. 사실 방사선측정의 대표적인 방법은 물팬톰-전리함응 이용한 모델인데 본 실험에서는 영상의 화소가 지니는 디지탈 값을 적절한 소프트웨어로 읽어내어서 데이터를 환산하여 결과를 얻었다. 선행실험에서 얻은 상대선량률을 적용하여 대칭성에서는 조사야영역이 l0$\times$10$cm^2$ 일 때 횡축과 종축에서 1.2%, 1.2%로 비교적 오차가 적었다. 그리고 Light/Radiation field congruence 여부는 횡축이 0.3%, 그리고 종축이 0.2%로서 예상한 기대값에 접근하였다. 다음으로 wedge filter를 활용한 에너지의 변이와 위치의 정확도에 대한 움직임을 알 수 있었다.

  • PDF

일개 한방병원에 내원한 유방암 환자의 특성 및 치료 분석 (Analysis of the Characteristics and Treatment of Breast Cancer Patients in a Korean Medicine Hospital)

  • 김규태;황영식;이진욱;박승혁;이진무;이창훈;장준복;황덕상
    • 대한한방부인과학회지
    • /
    • 제32권4호
    • /
    • pp.132-143
    • /
    • 2019
  • Objectives: The purpose of this study is to provide basic information on Korean medical research and treatment through analysis of breast cancer patients, who visited ${\bigcirc}{\bigcirc}$ university Korean medicine hospital. Methods: To analyze characteristics of breast cancer patients who visited korean medicine hospital, we searched medical records from January 1, 2016 to May 13, 2019, and 86 breast cancer patients were analyzed. Results: 1. The general characteristics of the subjects are as follows. The average age was $47.65{\pm}9.62years$ and 40's was the most (46.51%). The average height was $159.78{\pm}4.91cm$ and the average weight was $57.29{\pm}9.34kg$. The average body mass index (BMI) of the patients was $22.40{\pm}3.50kg/m^2$. 2. The stage distribution record indicated stage0 (9.72%), stageI (31.94%), stageII (34.72%), stageIII (20.83%) and stageIV (2.78%). 14 patients with unknown stage were excluded. 3. Before coming to the korean medicine hospital, of the 86 patients, 72 (83.72%) patients received surgical therapy, 55 (63.95%) patients received chemotherapy and 44 (51.16%) patients received radiotherapy. 11 (12.79%) patients chose oriental medicine as their primary treatment option. 4. The mean duration from diagnosis to hospital visit was $13.87{\pm}15.53months$. Among the total 86 patients, 46 (53.49%) patients visited for symptom relief during the follow-up period. 5. The most common symptom was general weakness in 29 (33.72%) patients, followed by hot flash, myalgia, insomnia, digestion disorder, numbness, edema, arthralgia, operation site pain, cold sensation and mastalgia. 6. Among 86 patients, 55 (63.95%) patients received acupuncture and moxibustion together. The most prescribed herbal medicine to subjects was Sibjeondaebo-tang-gamibang and Cheonhye-dan (25%). Conclusions: These results could be helpful to provide basic data on the Korean medical approach of breast cancer patients.