• Title/Summary/Keyword: FHA

Search Result 46, Processing Time 0.023 seconds

Research on the Multi - purpose Nd:YAG Laser Power System using LLC Converter (LLC 공진형 컨버터를 사용한 다용도 Nd:YAG 레이저 전원장치 설계)

  • Zheng, Tao;Kim, Hee-Je;Lee, Jae-cheol;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.885-890
    • /
    • 2015
  • LLC resonant converter has been widely used because of its high efficiency and high energy density. In this paper, we designed a LLC resonant converter as the main power supply of the Nd:YAG pulse laser. First harmonic approximation (FHA) is used to model the LLC resonant converter. FHA equivalent circuit model and the transfer function of the LLC resonant converter is proposed. Soft start technology is also used to suppress the surge current. The laser output simulation test result is identical with the practical test, the laser energy of every pulse can reach up to 2.5J, and the pulse per second (PPS) can be adjusted from 6 to 18. The power system is verified stable and reliable by both of the simulation and experiment results.

Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study

  • Woo, Hyun-Wook;Cho, Sung-Am;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.128-131
    • /
    • 2018
  • PURPOSE. This study aimed to evaluate the marginal discrepancy of full-arch frameworks in implant-supported prostheses fabricated using pre-sintered soft alloy (PSA). MATERIALS AND METHODS. Full-arch metal frameworks were fabricated on the edentulous implant model using casting alloy (CA), fully-sintered hard alloy (FHA), and PSA (n = 4 in each group). To evaluate the misfit of the framework to the abutments, the absolute marginal discrepancy (AMD) values of the frameworks were measured in cross-sectional images that had been drawn as part of the triple-scan protocol. The AMD values were compared among the tested alloy groups using the Kruskal-Wallis test, with a post hoc Mann-Whitney U test (${\alpha}=.05$). RESULTS. The FHA and PSA groups showed lower marginal discrepancies than the CA group (P<.001). However, the FHA group did not differ significantly from the PSA group. CONCLUSION. Soft alloy milling is comparable to hard alloy milling, and it is more precise than casting in terms of the marginal fit of implant-supported, full-arch prostheses.

A Study on the Control Characteristics of FHA by Using ERF and Industrial Controller (ERF와 산업용 콘트롤러를 이용한 FHA의 제어특성에 관한 연구)

  • Jang Sung-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.1
    • /
    • pp.95-100
    • /
    • 2005
  • Making the best use of the features of the electro-rheological(ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. In addition, the performance of the plate type ER-Valve is investigated by change the particle concentration of the ER fluid. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power control system. Using the minかnぉd pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system fir the ER Valve which occurs from industrial controller(PLC).

Protein Polvmorphisms and llariations of Wild House Rat (Rattus norueRicus) Population in Korea (한국산 야생집쥐(Rattus nowegicus) 집단의 단백질 다형과 유전적 변이)

  • 김남근;이하규이정주
    • The Korean Journal of Zoology
    • /
    • v.36 no.2
    • /
    • pp.193-199
    • /
    • 1993
  • The protein po;vmorphisms and allele frequencies of wild house rat (Rattus norvegicus) population in Korea were studied. The studied proteins and enzymes were transferrin (Tf), albumin (Alb), fumarate hvdratase (FH), phospho!loucomutase (PGM), lactate dehvdrogenase A (LDHA) and lactate dehvdrogenase B (LDHB). There were two transferrin alleles, TP and Tf in Korean wild house rat popu1ation. The Tf2 allele was found for the first time by a starch gel, and confirmed by a polvacrvlamide gel isoelectric focusing and immunoblotting. The allele frequencies of TP and TF were 0.985 and 0.015, respectively. Two common alleles fumarate hydratase, FHa and FHb were found, and frequencies of FHa and FPP were calculated to be 0.714 and 0.286, respectively. The kequenw of FH in Korean wild house rat was higher than that of Finnish and Czechoslovakian population. Alb, PGM, LDHA and LDHB are only one phenotype each and all. Therefore, these proteins seem to be monomorphic in Korean wild house rat population.

  • PDF

Safety Levels Apportionment in Railway System

  • Rafrafi, Meriem;El Koursi, El Miloudi;Bourdeaud'Huy, Thomas
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.157-168
    • /
    • 2008
  • The creation of a single European rail transport market it is important to increase confidence between the actors on the market and between member states who shall ensure that railway safety is generally maintained and, where reasonably practicable, continuously improved. For this purpose the European railway safety directive introduces a mechanism to adopt a Common Safety Targets (CST) expressed in risk acceptance criteria for individuals and for society. This paper focuses on the apportionment of safety targets for European railway system. We develop a generic approach based on the Functional Hazard Analysis (FHA), to analyse the safety of railway systems for a unified European network and to comply with the CSTs required by the European railway Safety Directive. We suggest to combine the FHA technique with the functional railway architecture to allocate the safety targets to the railway functions.

  • PDF

The Study of Criteria Weight for Taiwan National Quality Award by Fuzzy Hierarchical Analysis

  • Li, Shao-Chang;Fu, Hsin-Pin
    • International Journal of Quality Innovation
    • /
    • v.7 no.2
    • /
    • pp.83-96
    • /
    • 2006
  • In this paper, fuzzy hierarchical analysis (FHA) is used to explore the process by which the criteria weights of the Taiwan National Quality Award (TNQA) are assigned by TNQA committee members. Each member is allowed to employ fuzzy scales in place of exact scales. Each pairwise comparison of criteria is made through a questionnaire from each TNQA committee member. The membership function of trapezoidal fuzzy numbers is introduced to specify TNQA committee members' intentions. After FHA, the reasonable range of each criterion weight of TNQA is determined. The current criteria weights of TNQA are properly verified.

Resonant Tank Design Considerations and Implementation of a LLC Resonant Converter with a Wide Battery Voltage Range

  • Sun, Wenjin;Wu, Hongfei;Hu, Haibing;Xing, Yan
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1446-1455
    • /
    • 2015
  • This paper illustrates resonant tank design considerations and the implementation of a LLC resonant converter with a wide battery voltage range based on the fundamental harmonic approximation (FHA) analysis. Unlike the conventional design at zero load, the parameter K (the ratio of the transformer magnetizing inductor Lm to the resonant inductor Lr) of the LLC converter in this paper is designed with two charging points, (Vo_min, Io_max1) and (Vo_max, Io_max2), according to the battery charging strategy. A 2.9kW prototype with an output voltage range of 36V to 72V dc is built to verify the design. It achieves a peak efficiency of 96%.

The Effect of Different Head Positions in Sitting on Head/Shoulder Posture and Muscle Activity (앉은 자세에서 머리 위치가 머리/어깨의 자세와 근활성도에 미치는 영향)

  • Kwon, Jung-Won;Nam, Seok-Hyun;Choi, Yong-Won;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2013
  • Purpose: This study was to investigate whether the two different head postures, natural and ideal head posture, affect head/shoulder posture and muscle activity. Methods: Thirty healthy subjects with the forward head and round shoulder posture were participated in this study. This study utilized a within-subjects design with subjects being positioned into two sitting positions: natural head posture (NHP) and ideal head posture (IHP). Forward head angle (FHA) and forward shoulder angle (FSA) of each subject were measured for assessing the head/shoulder posture and muscle activities of upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA) during the forward overhead reaching. Results: There were significant increases in both FHA and FSA after taking IHP, which showed greater angles than in taking NHP. In change of muscle activities, there were significant decreases in both LT and SA after taking IHP, which showed lower activities than in taking a NHP, whereas there was no significant change in UT. Conclusion: These findings demonstrate that postural alterations associated with forward head and rounded shoulder postures could alter scapular kinetics and muscle activity during the forward overhead reaching.

Design Methodology for Transformers Including Integrated and Center-tapped Structures for LLC Resonant Converters

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.215-223
    • /
    • 2009
  • A design methodology for transformers including integrated and center-tapped structures for LLC resonant converters is proposed. In the LLC resonant converter, the resonant inductor in the primary side can be merged in the transformer as a leakage inductance. And, the absence of the secondary filter inductor creates low voltage stress on the secondary rectifiers and is cost-effective. A center-tapped structure of the transformer secondary side is widely used in commercial applications because of its higher efficiency and lower cost than full-bridge structures in the rectifying stages. However, this transformer structure has problems of resonance imbalance and transformer inefficiency caused by leakage inductance imbalance in the secondary side and the position of the air-gap in the transformer, respectively. In this paper, gain curves and soft-switching conditions are derived by first harmonic approximation (FHA) and operating circuit simulation. In addition, the effects of the transformer including integrated and center-tapped structures are analyzed by new FHA models and simulations to obtain an optimal design. Finally, the effects of the air-gap position are analyzed by an electromagnetic field simulator. The proposed analysis and design are verified by experimental results with a 385W LLC resonant converter.

A Study on the Control Characteristics of ER Valve-FHA System and Durability Test

  • Jang Sung-Cheol;Chang Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1621-1631
    • /
    • 2005
  • In this paper, making the best use of the features of the electro-rheological (ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power industry. Using the manufactured pressure control valve, a one-link manipulator with FHA (Flexible Hydraulic Actuator) is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller. After having durability test, shear stress increased regularly because of starch particles crushed by pump and particle size that was almost the same. Moreover, Ra of copper electrode increased about 1.56 times rather than before those of performing durability test, and Rz increased about 2.2 times.