• Title/Summary/Keyword: FFT signal Analyzer

Search Result 23, Processing Time 0.033 seconds

SCPI(Standard Commands for Programmable Instrument) Commands for FFT Analysis (FFT 분석을 위한 SCPI(Standard Commands for Programmable Instrument) 명령어)

  • 노승환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1384-1387
    • /
    • 1996
  • SCPI(Standard Commands for Programmable Instrument) is a standard command sets designed for controlling various types of instruments. In order to control FFT(Fast Fourier Transform) analyzing device using SCPI it is required to support sweep measurement function. We defined SCPI command set for FFT analysis and developed parser of defined command set using lex(Lexical Analyzer Generator) and yacc(Yet Another Compiler Compiler). After developing FFT analyzing test was performed with that parser. Up to audible signal frequency the result of FFT analysis was accurate and that result was agree with that of conventional FFT analyzer. As a result it is proved that various types of instruments including sweep measurement instrument can be controlled with appropriate SCPI command sets. Also when developing new instruments the method used in this experiment will contribute to reducing the time required to develop the SCPI parser and increasing reliability.

  • PDF

Implementation of a General Purpose DSP board using the ADSP-2105 Digital Signal Processor and its application to a real-time FFT analyzer (ADSP-2105를 이용한 범용 DSP 보드의 제작 및 이를 이용한 실시간 FFT 분석기의 구현)

  • 조철희
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06c
    • /
    • pp.61-64
    • /
    • 1994
  • 디지털 신호를 처리하기 위해 특별히 제작된 ADSP-2105는 빠른 Fied-point 연산과 Harvard-architecture로 구조화됐기 때문에 빠른 수행연산을 할 수 가 있다. 본 논문은 이 DSP 프로세서를 이용해 음성신호의 실시간 FFT 분석에 관한 방법을 소개한다. 실시간 FFT 분석기로서의 DSP 보드는 크게 음성신호를 받는 입력부분과 FFT를 계산하는 FFT 부분으로 나뉘어지는데, 입력부분은 AD1849로 8KHz로 데이터를 샘플링해 받게 되었고, FFT 부분은 실제로 DSP가 FFT를 수행하는 부분으로 되어있다. 실시간 처리를 구현하기 위해 입력 부분은 두 개의 뱅크로 만들어 한 뱅크에서 음성신호를 받아들이는 동안에 다른 뱅크에서는 FFT를 계산하도록 되어있어서 DSP 보드는 항시 음성신호를 샘플링 할 수 있는 상태를 유지할 수 있다. 그리고 FFT 처리부는 빠른 처리로 음성신호를 샘츨링할 뱅크가 채워지기 전에 실행되게 프로그램되어 있어 실제적으로 모든 음성데이타를 FFT 하게 되어있다.

  • PDF

Design and Construction of a FFT Analyzer Using a Microcomputer (마이크로컴퓨터를 이용한 FFT 분석기의 설계 및 제작)

  • Lee, Hyeun Tae;Kim, Jung Gyu;Lee, Sang Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.6
    • /
    • pp.944-949
    • /
    • 1986
  • By improving the ability of arithmatic processing with an arithmatic processor in a microcomputer and realizing the data input system for real time analysis, an FFT analyzer that is usable within the range of audio frequency is designed and constructed. The input signal passes through a gain programmable pre-amplifier and anti-aliasing lowpass filter into an analogditital converter to be converted into digital form. The converted input data is processed by an Apple II microcomputer. The results of the processing are displayed using a microcomputer display unit and can be copied on a printer or stored in a floppy disk.

  • PDF

Development of Data Acquistion and Processing System for the Analysis of Biophysiological signal (생체신호 처리를 위한 시스템 개발)

  • 이준하;이상학;신현진
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • This study describes the design of the biophysiological signal processing analyzer which can collect and analyze the biosignal raw data. System hardware is consisted of the IBM PC AT. pre-amplifier. AID converter, Counter/Timer. and RS-232C processor. Biophysiological signal data were processed by the software digital filter. FFT and graphic processing routine. The tachogram and FFT of the the peak to peak interval time was accomplished by the Graphic user interface software using the biophysiological signal processed data. Using this system. the powerspectrum of the heart rate variability during the long term could be observed. Experimental results of this system approach our purpose. which is improved the cost performance. easy to use. reducing raw-data noise and optimizing model for digital filter.

  • PDF

Design and Implementation of A VXIbus Device for FFT Analysis (FFT분석을 위한 VWIbus 디바이스의 설계 및 구현)

  • 강민호;노승환;전동근;문대철;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1754-1766
    • /
    • 1993
  • The application of VXIbus system, an Industry standard, is rapidly spreading with its ability to offer the easiness of integration from GPIB and the fast data transmission from VMEbus system. Compared with VXIbus Register Based Device, VXIbus Message Based Device has a drawback In the aspect of speed. But it is possible to utilize high level ASCII commands to control a Message Based Device, therefore system integration is much easier with Message Based Device than with Register Based Device. And, the FFT analyzer is an instrument for signal analysis which can be inexpensively implemented to be fast and have high resolution. Its wide ability of analysis presents numerous application. So, it is necessary to apply VXIbus system to FFT analyzer. In this paper, the implementation of FFT analyzer is performed using a DSP module and by implementing all A/D conversion circuit and a control module which performs VXIbus interface. The device can be controlled by Slot0 Commender which supports VXIbus Shared Memory Protocol through VXIbus.

  • PDF

Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode (광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정)

  • Yoo, W.J.;Lee, G.S.;Kim, J.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF

A study on the DSP Analysis for the CAT application (CAT 응용을 위한 신호처리 분석에 관한 연구)

  • Jeon, Dong-Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.30-39
    • /
    • 1995
  • In this paper, study on implementation of FFT analyzer applied to CAT, A/D conversion module, DSP module and VXIbus interface module are implemented in hardware and calculation program and control software are implemented in DSP module and VXIbus interface module, respectively. The control of the modules using PC is realized in software. The real time bandwidth of the FFT analyzing device is 100KHz. At sampling rate of 200KHz and with 2048 point FFT, the result of applying sine, triangular and rectangular wave of 20KHz to FFT analyzing device is compared with the FFT analyzed results of Hewlett-Packard 3562A dynamic output range of -40dBV- +30dBV, correct results are obtained and results of applying 10KHz, 20KHz and 50KHz input are compared and the correct values are obtained.

  • PDF

The Measurement Systme of Vibration using Laser (레이져를 이용한 진동측정장치)

  • 진동희;전병철;조종두;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.357-362
    • /
    • 1993
  • In this study low priced laser measurement system was made, so its reliability was investigated Intensity distribution of laser beam measured by devised system and FFT analyzer and their results were examined for proving reliability of devised system. Transmitted laser beam intensity on photodiode changed by eccentrically rotating of disk cam and motor speed. To get results, photodiode and devised amplifier were used for changing voltage. After that, response signal was calculated by signal analysis program. It was found that the vibration of disk cam could be measured by the intensity distribution of laser beam and the same tendency was obtained by FFT. Change of motor speed effected the distribution of laser beam,which was obtained by devised system. Also linear distribution was got by sensitive balancing switch on amplifier according to the transmission of laser beam on photodide.

  • PDF

A Study on Implementation of a VXIbus System Using Shared Memory Protocol (공유메모리 프로토콜을 이용한 VXIbus 시스템 구현에 관한 연구)

  • 노승환;강민호;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1332-1347
    • /
    • 1993
  • Existing instruments are composed independently according to their function and user constructed instrumentation system with those instruments. But in the late 1980s VXI bus enables to construct instrumentation system with various modular type instruments. For an VXI bus system with the word serial protocol, an increase of data size can degrade the system performance. In this paper shared memory protocol is proposed to overcome performance degradation. The shared memory protocol is analyzed using the GSPN and compared with that of the word serial protocol. It is shown that the shared memory protocol has a better performance than the word serial protocol. The VXI bus message based-system with the proposed shared memory protocol is constructed and experimented with signal generating device and FFT analyzing device. Up to 80 KHz input signal the result of FFT analysis is accurate and that result is agree with that of conventional FFT analyzer. In signal generating experiment from 100 KHz to 1.1 GHz sine wave is generated.

  • PDF