• Title/Summary/Keyword: FE-simulations

Search Result 242, Processing Time 0.022 seconds

Empirical Relationship Between SP-curves and Tensile Properties in Mn-Mo-Ni Low Alloy Steels (Mn-Mo-Ni 저합금강의 SP-곡선과 인장물성과의 실험적 관계)

  • Lee, Jae-Bong;Kim, Min-Chul;Park, Jai-Hak;Lee, Bong-Sang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.554-562
    • /
    • 2004
  • An empirical relationship between parameters from SP curves and tensile properties has been systematically investigated by experimental tests and FEM simulations. A series of SP and tensile tests were performed. SP tests were also simulated by FE analysis with various tensile properties. It was found that the yield loads(Py) and the maximum loads( $P_{MAX}$) in SP curves were linearly related with the yield strength($\sigma$$_{o}$) and the tensile strength($\sigma$$_{UTS}$), respectively. The yield loads defined from the intersection point of two lines tangent to the elastic bending region and plastic bending region showed better relation to the yield strength than those from offset line. The maximum loads in SP curves showing plastic instability region was linearly related with the tensile strengths. The slope of SP curves in simulation results had a close correlation with the hardening coefficient and hardening strength as well.l.l.l.

Experimental and Theoretical Investigations on the Fracture Criteria for Structural Steels (구조물용 강재의 파단기준에 대한 실험 및 이론 연구)

  • Choung, Joon-Mo;Cho, Sang-Rai
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Six smooth flat tensile specimens and eighteen punch specimens with three different thicknesses were machined from steel of JIS G3131 SPHC. In addition to punch tests, incremental tensile tests were conducted to obtain average true flow stress - logarithmic true strain curves. Through parametric FE simulations for the tensile specimens, material parameters related to GTN model were identified. Using indenters with three kinds of radius, punch tests were carried out to obtain fracture characteristics of punch specimens. Numerical analyses using both fracture models, GTN and $J_2$ plasticity model, gave that the former estimated well the fracture of punch specimen but the latter did not. A new concept for critical size of plate elements was introduced based on minimum relative sharpness between contact structures. Consequently, a new criterion for critical element size was proposed to be less than 20% of minimum relative radius of interacting structures.

Improvement on the Formability of Magnesium Alloy Sheet by Heating and Cooling Method (가열냉각방법에 의한 마그네슘합금의 판재성형성 개선)

  • Kang Dae-Min;Manabe Ken-ich
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this study is to confirm the improvement of formability of AZ31 magnesium alloy sheet by using local heating and cooling technique. For this, the experiments of warm deep drawing were done under the temperatures of $100^{\circ}C\~400^{\circ}C$, and the punch velocity of 10, 100mm/min. Also FE analysis under the temperatures of blankholder and die of $150^{\circ}C,\;225^{\circ}C\;and\;300^{\circ}C$ for tools(holder and die) was executed with considering heat teansfer. From the results, the formability of AZ31 magnesium alloy, espicially the temperatures of $225^{\circ}C\~250^{\circ}C$ for tools(holder and die)improved remarkably. And the experiments and simulations showed that necking under room temperature for tools occured under the part of punch shoulder while at $300^{\circ}C$ for tools, at the part of die shoulder.

Optimized finite element model updating method for damage detection using limited sensor information

  • Cheng, L.;Xie, H.C.;Spencer, B.F. Jr.;Giles, R.K.
    • Smart Structures and Systems
    • /
    • v.5 no.6
    • /
    • pp.681-697
    • /
    • 2009
  • Limited, noisy data in vibration testing is a hindrance to the development of structural damage detection. This paper presents a method for optimizing sensor placement and performing damage detection using finite element model updating. Sensitivity analysis of the modal flexibility matrix determines the optimal sensor locations for collecting information on structural damage. The optimal sensor locations require the instrumentation of only a limited number of degrees of freedom. Using noisy modal data from only these limited sensor locations, a method based on model updating and changes in the flexibility matrix successfully determines the location and severity of the imposed damage in numerical simulations. In addition, a steel cantilever beam experiment performed in the laboratory that considered the effects of model error and noise tested the validity of the method. The results show that the proposed approach effectively and robustly detects structural damage using limited, optimal sensor information.

Probabilistic Strength at Serviceability Limit State for Normal and SBHS Slender Stiffened Plates Under Uniaxial Compression

  • Rahman, Mahmudur;Okui, Yoshiaki;Anwer, Muhammad Atif
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1397-1409
    • /
    • 2018
  • Stiffened plates with high slenderness parameters show large out-of-plane deflections, due to elastic buckling, which may occur before the plates reach their ultimate strength. From a serviceability point of view, restriction of out-of-plane deflections exceeding the fabrication tolerance is of primary importance. Compressive strength at the serviceability limit state (SLS) for slender stiffened plates under uniaxial stress was investigated through nonlinear elasto-plastic finite element analysis, considering both geometric and material nonlinearity. Both normal and high-performance steel were considered in the study. The SLS was defined based on a deflection limit and an elastic buckling strength. Probabilistic distributions of the SLS strengths were obtained through Monte Carlo simulations, in association with the response surface method. On the basis of the obtained statistical distributions, partial safety factors were proposed for SLS. Comparisons with the ultimate strength of different design codes e.g. Japanese Code, AASHTO, and Canadian Code indicate that AASHTO and Canadian Code provide significantly conservative design, while Japanese Code matches well with a 5% non-exceedance probability for compressive strength at SLS.

Optimum stiffness values for impact element models to determine pounding forces between adjacent buildings

  • Jaradat, Yazan;Far, Harry
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.293-304
    • /
    • 2021
  • Structural failure due to seismic pounding between two adjacent buildings is one of the major concerns in the context of structural damage. Pounding between adjacent structures is a commonly observed phenomenon during major earthquakes. When modelling the structural response, stiffness of impact spring elements is considered to be one of the most important parameters when the impact force during collision of adjacent buildings is calculated. Determining valid and realistic stiffness values is essential in numerical simulations of pounding forces between adjacent buildings in order to achieve reasonable results. Several impact model stiffness values have been presented by various researchers to simulate pounding forces between adjacent structures. These values were mathematically calculated or estimated. In this study, a linear spring impact element model is used to simulate the pounding forces between two adjacent structures. An experimental model reported in literature was adopted to investigate the effect of different impact element stiffness k on the force intensity and number of impacts simulated by Finite Element (FE) analysis. Several numerical analyses have been conducted using SAP2000 and the collected results were used for further mathematical evaluations. The results of this study concluded the major factors that may actualise the stiffness value for impact element models. The number of impacts and the maximum impact force were found to be the core concept for finding the optimal range of stiffness values. For the experimental model investigated, the range of optimal stiffness values has also been presented and discussed.

Prediction of shear strength and drift capacity of corroded reinforced concrete structural shear walls

  • Yang, Zhihong;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • v.83 no.2
    • /
    • pp.245-257
    • /
    • 2022
  • As the main lateral load resisting system in high-rise reinforced concrete structures, the mechanical performance of shear wall has a significant impact on the structure, especially for high-rise buildings. Steel corrosion has been recognized as an important factor affecting the mechanical performance and durability of the reinforced concrete structures. To investigate the effect on the seismic behaviour of corroded reinforced concrete shear wall induced by corrosion, analytical investigations and simulations were done to observe the effect of corrosion on the ultimate seismic capacity and drift capacity of shear walls. To ensure the accuracy of the simulation software, several validations were made using both non-corroded and corroded reinforced concrete shear walls based on some test results in previous literature. Thereafter, a parametric study, including 200 FE models, was done to study the influence of some critical parameters on corroded structural shear walls with boundary element. These parameters include corrosion levels, axial force ratio, aspect ratio, and concrete compressive strength. The results obtained would then be used to propose equations to predict the seismic resistance and drift capacity of shear walls with various corrosion levels.

Structural behavior of concrete walls reinforced with ferrocement laminates

  • Shaheen, Yousry B.I.;Refat, Hala M.;Mahmoud, Ashraf M.
    • Structural Engineering and Mechanics
    • /
    • v.78 no.4
    • /
    • pp.455-471
    • /
    • 2021
  • The present work focuses on experimental and numerical performance of the ferrocement RC walls reinforced with welded steel mesh, expanded steel mesh, fiber glass mesh and tensar mesh individually. The experimental program comprised twelve RC walls having the dimensions of 450 mm×100 mm×1000 mm under concentric compression loadings. The studied variables are the type of reinforcing materials, the number of mesh layers and volume fraction of reinforcement. The main aim is to assess the influence of engaging the new inventive materials in reinforcing the composite RC walls. Non-linear finite element analysis; (NLFEA) was carried out to simulate the behavior of the composite walls employing ANSYS-10.0 Software. Parametric study is also demonstrated to check out the variables that can mainly influence the mechanical behavior of the model such as the change of wall dimensions. The obtained numerical results indicated the acceptable accuracy of FE simulations in the estimation of experimental values. In addition, the strength gained of specimens reinforced with welded steel mesh was higher by amount 40% compared with those reinforced with expanded steel mesh. Ferrocement specimens tested under axial compression loadings exhibit superior ultimate loads and energy absorbing capacity compared to the conventional reinforced concrete one.

An SDOF model of a four-sided fixed RC wall having an opening for blast response simulation

  • S.H., Sung;H., Ji
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.675-684
    • /
    • 2022
  • The conventional single-degree-of-freedom (SDOF) system is appropriate for dynamic response analysis of paneltype structures without an opening. However, the typical building structures usually have four-sided fixed walls having an opening. Therefore, it may induce a considerable error when dynamic responses are estimated based on the conventional SDOF system, since the SDOF system cannot consider the effect of an opening during the SDOF analysis. For this reason, this study proposes a new SDOF system to consider the effect of an opening by adjusting its load-mass factor. The load-mass factor can be modified based on the assumption that the behaviors of the four-sided fixed wall with an opening is very similar to the behaviors of the same size wall without an opening, when the uniformly distributed blast loaded area is identical. In order to confirm a feasibility of the proposed SDOF system, a series of numerical simulations were carried out for the four-sided fixed reinforced concrete (RC) wall under a blast load. The dynamic responses estimated from the proposed SDOF system and the conventional SDOF system were compared with the dynamic responses evaluated from the finite element (FE) analysis. Especially, for the maximum dynamic responses except for 50% opening case, the proposed SDOF system had about 1.1% to 25.7% normalized errors while the conventional SDOF system had about 4.1% to 49.1% normalized errors.

A numerical study on shear response of concrete-filled stainless steel tubes

  • Sina Kazemzadeh Azad;Brian Uy
    • Steel and Composite Structures
    • /
    • v.48 no.5
    • /
    • pp.507-530
    • /
    • 2023
  • The number of studies investigating the response of concrete-filled tubes (CFTs) under shear has been very limited in the literature. This lack of research has been traditionally reflected in international design standards as rather conservative shear strength predictions for CFTs. The dearth of research on the shear response is even more pronounced for the case of concrete-filled stainless steel tubes (CFSSTs). In line with this, the present study investigates the shear response of circular and square CFSSTs using advanced finite element (FE) analysis. A thorough review of the previous studies on the shear response of carbon steel CFTs is provided along with a summary of past experimental programmes as well as the developed and codified design methods. A comprehensive numerical study is then conducted considering a wide range of circular and square, austenitic and lean duplex CFSSTs with different concrete infills and shear span-to-depth ratios. The effect of the tail length on the shear response is investigated and the minimum required tail length for achieving full shear capacity is established. The simulations are also used to highlight the importance of the dilation of the concrete core in the shear response of concrete-filled tubes and its relationship with the utilised boundary conditions. Furthermore, the numerical results are compared in detail with the predictions of design approaches developed previously for carbon steel CFTs and their accuracy and applicability to the stainless steel counterpart are demonstrated and recommendations are made accordingly.