• 제목/요약/키워드: FE analysis method

검색결과 1,523건 처리시간 0.025초

항공기 지상 진동 시험 및 동특성 모델의 개선 (The Ground Vibration Test on an Aircraft and FE Model Update)

  • 유홍주;변관화;박금룡
    • 소음진동
    • /
    • 제8권4호
    • /
    • pp.690-699
    • /
    • 1998
  • This paper discusses the techniques, procedures and the results of the ground vibration test(GVT) performed on the development aircraft and the simple procedure of FE model updating technique from the GVT results. The GVT was carried out using random excitation technique with MIMO(Multi-Input-Multi-Output) data acquistion method, and taking full advantage of poly-reference global parameter estimation technique to identify the vibration modes. In dynamic FE modeling, the aircraft was represented by beam elements and all dynamic analysis was performed using MSC/NASTRAN for this model. In updating procedure, the stiffness of the beam model was adjusted iteratively so as to get the natural frequencies and mode shapes close to the GVT results.

  • PDF

수소제조를 위한 다공성 FeCrAl 금속 합금 Foam의 NiO 촉매 담지 및 미세구조 분석 (Synthesis and Microstructure Analysis of NiO Catalysts Coated on the FeCrAl Metal Alloy Foam for Hydrogen Production)

  • 이유진;안건형;박만호;이창우;최상현;정주용;조성종;이근재;안효진
    • 한국재료학회지
    • /
    • 제24권8호
    • /
    • pp.393-400
    • /
    • 2014
  • NiO catalysts were successfully coated onto FeCrAl metal alloy foam as a catalyst support via a dip-coating method. To demonstrate the optimum amount of NiO catalyst on the FeCrAl metal alloy foam, the molar concentration of the Ni precursor in a coating solution was controlled, with five different amounts of 0.4 M, 0.6 M, 0.8 M, 1.0 M, and 1.2 M for a dip-coating process. The structural, morphological, and chemical bonding properties of the NiO-catalyst-coated FeCrAl metal alloy foam samples were assessed by means of field-emission scanning electron microscopy(FESEM), scanning electron microscopy-energy dispersive spectroscopy(SEM-EDS), X-ray diffraction(XRD), and X-ray photoelectron spectroscopy(XPS). In particular, when the FeCrAl metal alloy foam samples were coated using a coating solution with a 0.8 M Ni precursor, well-dispersed NiO catalysts on the FeCrAl metal alloy foam compared to the other samples were confirmed. Also, the XPS results exhibited the chemical bonding states of the NiO phases and the FeCrAl metal alloy foam. The results showed that a dip-coating method is one of best ways to coat well-dispersed NiO catalysts onto FeCrAl metal alloy foam.

METHOD OF FATIGUE LIFE PREDICTION FOR SPOT WELDED STRUCTURE

  • Okabe, A.;Kaneko, T.;Tomioka, N.
    • International Journal of Automotive Technology
    • /
    • 제7권3호
    • /
    • pp.353-360
    • /
    • 2006
  • The nominal structural stress calculation method proposed by Radaj has included some problems as follows: (a) How the value of the diameter D is decided in the method; (b) It is not possible to estimate nominal structural stress of the spot welded joints with the balanced sheet in-plane load that no general loads are obtained by FE shell analysis. In this paper, the new method for calculating nominal structural stress was proposed to solve above-mentioned problems. The proposed method calculates the nominal structural stress through the circular plate theory in theory of elasticity. This theoretical analysis uses not only general loads but also nodal displacements around spot welding provided by FE shell analysis as boundary condition. Fatigue test data of various spot-welded joints could be arranged in a narrow bandwidth on S-N chart using the nominal structural stresses calculated by proposed method. The fatigue life prediction method using the proposed method for calculating nominal structural stress is useful for the prior evaluation technique that can predict the fatigue life of spot welding by CAE.

전달함수합성법을 이용한 차량용 에어컨 컴프레서 브라켓의 동특성 해석 (Dynamic Analysis of Compressor Mounting Bracket using FRF-based Substructuring Method)

  • 정홍석;서세영;이두호;김찬묵
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.194-200
    • /
    • 2000
  • Researches on the FRF-based substructuring method have been mainly focused on vibratory response analysis. Present study is concerned about the application of the method to the dynamic stress analysis of a compressor mounting bracket in a passenger car. This is performed by using reaction forces that can be obtained by the FRF-based substructuring method. The air-conditioner system, composed of a compressor, a bracket and a test jig, is analyzed by using the FRF-based substructuring method. The experimental and numerical FRFs are combined to calculate the system responses and reaction forces at the connection point. The dynamic reaction forces plugged into the bracket FE model to compute the compute the stresses of the bracket. Dynamic stresses by the present method are compared with those from FE model. The comparison shows possibility of practical usage of the method for the real problem.

  • PDF

하중기반 유한요소모델에 의한 FRP 보강 철근콘크리트 기둥의 비선형 해석 (Nonlinear Analysis of FRP Strengthened Reinforced Concrete Columns by Force-Based Finite Element Model)

  • 조창근
    • 콘크리트학회논문집
    • /
    • 제25권5호
    • /
    • pp.529-537
    • /
    • 2013
  • 이 연구의 목적은 하중기반 유한요소 정식화에 의한 FRP 보강된 철근콘크리트 보 또는 기둥 부재의 비선형 층상화의 등매개 골조 유한요소모델을 개발하는데 있다. 단면에서 콘크리트는 3축 응력-변형률 관계로 모델화하고 FRP 피복층은 2차원의 적층복합재료로 모델화하였다. 하중기반 유한요소의 요소강성행렬은 변위형상함수의 가정이 없고 하중보간함수를 갖고 있다. 횡 하중을 받는 GFRP 시트 보강된 철근콘크리트 기둥의 실험에 대해 개발된 하중기반 유한요소모델에 의한 해석을 수행하였다. 기존 강성도법의 유한요소해석과 비교하여 하중기반 유한요소해석은 전체적인 하중-변위 관계 뿐만 아니라 기둥의 소성힌지영역에서의 비선형 변형 및 손상을 보다 정확히 예측해 주었다.

스플라인 이형인발을 위한 중간 다이 단면형상 설계 (Design of the Cross Sectional Shape of Intermediate Die for Shaped Drawing of Spline)

  • 이재은;이태규;이상곤;김병민
    • 소성∙가공
    • /
    • 제17권8호
    • /
    • pp.627-632
    • /
    • 2008
  • The cross sectional shape of intermediate die is one of important parameters to improve dimensional accuracy of final product in shaped drawing process. Until now, it has been designed by the experience or trial and error of the expert. In this study, the cross sectional shape of intermediate die for spline shape is determined by the electric fields analysis and scale factor method. The result of the electric fields analysis and scale factor method have been compared with that of the expert method. The effects of cross sectional shape on the dimensional accuracy were investigated by using FE-simulation. And then the multi-stage shaped drawing experiments were performed to verify the results of FE-simulation. As a result, the cross sectional shape from the electric fields analysis and scale factor method had the good dimensional accuracy. These two methods can be used for the method to obtain the cross sectional shape of intermediate die in shaped drawing process.

비선형 유한요소법을 이용한 자동차 도어 웨더스트립의 접촉변형에 관한 연구 (A Study on Contact Deformation of Automotive Door Weatherstrip Using Non-linear Finite Element Method)

  • 김병수;문병영;김광훈
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2005
  • In vehicle door system, weatherstrip seals protect passengers form noise, dust, rain and wind out of the vehicle. The higher efficient a weatherstrip is, the more durable it is in contact between the door and body frame. In this study, nonlinear finite element(FE) analysis is performed to obtain cauchy-stresses, displacements and reaction forces of the weatherstrip. Mechanical properties of the weatherstrip is obtained by uniaxial tension test. The MARC which is a commercial software for the nonlinear analysis of a flexible FE model is used. Twenty-one cases of the FE model are developed by using Ogden-foam formulation. In the results of nonlinear FE analysis, the most valuable deformation of the weatherstrip occurred when displacement control value reaches 7.2mm. Severe deformation is observed as the displacement control value become more increased. When the weatherstrip is designed, it would be considered that the displacement value of the weatherstrip has to be less than 7.2mm.

Dynamic analysis of Pine Flat dam-reservoir system utilizing Hagstrom-Warburton truncation boundary condition

  • Solmaz Dehghanmarvasty;Vahid Lotfi
    • Coupled systems mechanics
    • /
    • 제12권4호
    • /
    • pp.365-389
    • /
    • 2023
  • Dynamic analysis of a typical concrete gravity dam-reservoir system is formulated by FE-(FE-TE) approach (i.e., Finite Element-(Finite Element-Truncation Element)). In this technique, dam and reservoir are discretized by plane solid and fluid finite elements. Moreover, the H-W (i.e., Hagstrom-Warburton) high-order condition imposed at the reservoir truncation boundary. This task is formulated by employing a truncation element at that boundary. It is emphasized that reservoir far-field is excluded from the discretized model. The formulation is initially reviewed which was originally proposed in a previous study. Thereafter, the response of Pine Flat dam-reservoir system is studied due to horizontal and vertical ground motions for two types of reservoir bottom conditions of full reflective and absorptive. It should be emphasized that study is carried out under high order of H-W condition applied on the truncation boundary. The initial part of study is focused on the time harmonic analysis. In this part, it is possible to compare the transfer functions against corresponding responses obtained by FE-(FE-HE) approach (referred to as exact method). Subsequently, the transient analysis is carried out. In that part, it is only possible to compare the results for low and high normalized reservoir length cases. Therefore, the sensitivity of results is controlled due to normalized reservoir length values.

Structural integrity assessment procedure of PCSG unit block using homogenization method

  • Gyogeun Youn;Wanjae Jang;Youngjae Jeon;Kang-Heon Lee;Gyu Mahn Lee;Jae-Seon Lee;Seongmin Chang
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1365-1381
    • /
    • 2023
  • In this paper, a procedure for evaluating the structural integrity of the PCSG (Printed Circuit Steam Generator) unit block is presented with a simplified FE (finite element) analysis technique by applying the homogenization method. The homogenization method converts an inhomogeneous elastic body into a homogeneous elastic body with same mechanical behaviour. This method is effective when the inhomogeneous elastic body has repetitive microstructures, and thus the method was applied to the sheet assembly among the PCSG unit block components. From the method, the homogenized equivalent elastic constants of the sheet assembly were derived. The validity of the determined material properties was verified by comparing the mechanical behaviour with the reference model. Thermo-mechanical analysis was then performed to evaluate the structural integrity of the PCSG unit block, and it was found that the contact region between the steam header and the sheet assembly is a critical point where large bending stress occurs due to the temperature difference.

Postfire reliability analysis of axial load bearing capacity of CFRP retrofitted concrete columns

  • Cai, Bin;Hao, Liyan;Fu, Feng
    • Advances in concrete construction
    • /
    • 제10권4호
    • /
    • pp.289-299
    • /
    • 2020
  • A reliability analysis of the axial compressive load bearing capacity of postfire reinforced concrete (RC) columns strengthened with carbon fiber reinforced polymer (CFRP) sheets was presented. A 3D finite element (FE) model was built for heat transfer analysis using software ABAQUS. Based on the temperature distribution obtained from the FE analysis, the residual axial compressive load bearing capacity of RC columns was worked out using the section method. Formulas for calculating the residual axial compressive load bearing capacity of the columns after fire exposure and the axial compressive load bearing capacity of postfire columns retrofitted with CFRP sheets were developed. Then the Monte Carlo method was used to analyze the reliability of the axial compressive load bearing capacity of the RC columns retrofitted with CFRP sheets using a code developed in MATLAB. The effects of fire exposure time, load ratio, number of CFRP layers, concrete cover thickness, and longitudinal reinforcement ratio on the reliability of the axial compressive load bearing capacity of the columns after fire were investigated. The results show that within 60 minutes of fire exposure time, the reliability index of the RC columns after retrofitting with two layers of CFRPs can meet the requirements of Chinese code GB 50068 (GB 2001) for safety level II. This method is effective and accurate for the reliability analysis of the axial load bearing capacity of postfire reinforced concrete columns retrofitted with CFRP.