• Title/Summary/Keyword: FDG PET-CT

Search Result 407, Processing Time 0.03 seconds

The Prognostic Value of 18F-Fluorodeoxyglucose PET/CT in the Initial Assessment of Primary Tracheal Malignant Tumor: A Retrospective Study

  • Dan Shao;Qiang Gao;You Cheng;Dong-Yang Du;Si-Yun Wang;Shu-Xia Wang
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.425-434
    • /
    • 2021
  • Objective: To investigate the potential value of 18F-fluorodeoxyglucose (FDG) PET/CT in predicting the survival of patients with primary tracheal malignant tumors. Materials and Methods: An analysis of FDG PET/CT findings in 37 primary tracheal malignant tumor patients with a median follow-up period of 43.2 months (range, 10.8-143.2 months) was performed. Cox proportional hazards regression analyses were used to assess the associations between quantitative 18F-FDG PET/CT parameters, other clinic-pathological factors, and overall survival (OS). A risk prognosis model was established according to the independent prognostic factors identified on multivariate analysis. A survival curve determined by the Kaplan-Meier method was used to assess whether the prognosis prediction model could effectively stratify patients with different risks factors. Results: The median survival time of the 37 patients with tracheal tumors was 38.0 months, with a 95% confidence interval of 10.8 to 65.2 months. The 3-year, 5-year and 10-year survival rate were 54.1%, 43.2%, and 16.2%, respectively. The metabolic tumor volume (MTV), total lesion glycolysis (TLG), maximum standardized uptake value, age, pathological type, extension categories, and lymph node stage were included in multivariate analyses. Multivariate analysis showed MTV (p = 0.011), TLG (p = 0.020), pathological type (p = 0.037), and extension categories (p = 0.038) were independent prognostic factors for OS. Additionally, assessment of the survival curve using the Kaplan-Meier method showed that our prognosis prediction model can effectively stratify patients with different risks factors (p < 0.001). Conclusion: This study shows that 18F-FDG PET/CT can predict the survival of patients with primary tracheal malignant tumors. Patients with an MTV > 5.19, a TLG > 16.94 on PET/CT scans, squamous cell carcinoma, and non-E1 were more likely to have a reduced OS.

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

The Diagnostic Utility of PET-CT for the Preoperative Evaluation of Lymph Node Metastasis in Gastric Cancer Patients (위암 환자의 수술 전 림프절 전이 평가를 위한 PET-CT의 진단적 유용성)

  • Park, Sung-Hyuk;Cho, Min-Su;Ryu, Hoon;Bae, Keum-Seok;Kim, Ik-Yong;Kim, Dae-Sung
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.250-255
    • /
    • 2008
  • Purpose: The purpose of this study was to assess the diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for detecting the lymph node (LN) metastasis of gastric cancer. Materials and Methods: 119 patients (M : F=89 : 30; mean age: 64) with gastric cancer were referred for preoperative FDG-PET/CT scanning and spiral enhanced abdominal pelvic CT from June 2006 to July 2008, and these were the subjects of our study. All the patients underwent curative radical gastrectomy and lymph node dissection. A final diagnosis was made for all the patients by the histology of the surgical specimens. Results: Both PET/CT and enhanced CT showed similar sensitivity for detecting regional lymph node metastasis (32.6% vs 39.5%, respectively). PET/CT was more accurate than enhanced CT for detecting regional lymph node metastasis (67.2% vs 63.0%, respectively), and PET/CT showed better specificity (86.8% vs 76.3, respectively) and a better positive predictive value (PPV) (58.3% vs 48.6%, respectively). PET/CT showed better specificity (98.0% vs 88.2%, respectively) and accuracy (79.4% vs 73.9%, respectively) than enhanced CT for detecting early gastric cancer. PET/CT showed better specificity (64.0% vs 52.0%, respectively), a better PPV (60.9% vs 57.1%), a better negative predictive value (NPV) (48.5% vs 46.4%, respectively) and better accuracy (53.6% vs 51.8%, respectively) than enhanced CT for detecting advanced gastric cancer. Conclusion: FDG-PET/CT is more usefulness than enhanced CT for making the preoperative diagnosis of regional LN metastases from gastric cancers.

  • PDF

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

Isolated Splenic Metastasis of Sigmoid Colon Cancer Detected by $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT 에서 발견된 S상 결장암의 단일 비장 전이)

  • An, Young-Sil;Yoon, Joon-Kee;Hong, Seon-Pyo;Choi, Bong-Hoi;Joh, Chul-Woo;Yoon, Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.263-264
    • /
    • 2007
  • Splenic metastasis from colon carcinoma are rare and usually occur in the presence of disseminated visceral metastasis. The liver is the most common site of metastatic spread from colon cancer. Several hypotheses have attempted to explain the low incidence of splenic metastasis. It should be difficult for colorectal cancer cells to reach the spleen through the portal venous system, in which the blood flow is usually from the spleen to the liver. Reticuloendothelial system or rhythmic contraction of the spleen may squeeze out the tumor in the spleen. The absence of afferent lymphatic to the spleen, phagocytic activity and humoral anticancer substances are considered to be other reason for low incidence of splenic metastasis. We report the case of $^{18}F-FDG$ PET/CT finding in a 70-year-old woman who develop isolated splenic metastasis of sigmoid colon cancer.

Discussion of COVID-19 Vaccination and Axillary Lymph Nodes Uptake in 18F-FDG PET/CT (18F-FDG PET/CT에서 코로나 백신접종과 액와 림프절 섭취에 대한 고찰)

  • Min-Chan, Kim;Yong-Hoon, Choi;Han-Sang, Lim;Jae-Sam, Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.32-36
    • /
    • 2022
  • Purpose There are reports that the COVID-19 vaccine causes false positive uptake of axillary lymph nodes. Therefore, this paper intends to evaluate the change in SUVmax of axillary lymph nodes with the period after the COVID-19 vaccination. Materials and Methods In 134 breast cancer patients who were tested for 18F-FDG PET/CT at Severance hospital, 3.7 MBq/kg of 18F-FDG was intravenously injected and scanned for 2 minutes per bed after 60 minutes. The equipment was Discovery 600 (GE Healthcare, MI, USA). The period was divided into four groups, 0 to 2 weeks, 3 to 6 weeks, 7 to 10 weeks, and 11 weeks or more. SUVmax was measured after checking the uptake of axillary lymph nodes on the ipsilateral side of vaccination and the Kruskal-Wallis test was performed using SPSS Statistics 28 (IBM Corp., Armonk, NY, USA). Results From 0 to 2 weeks groups to 11 weeks or more group, the average of SUVmax was measured in the order of 5.52, 2.85, 1.82, and 1.7. As a result of the Kruskal-Wallis test, there was a significant difference between 0 to 2 weeks group from all other groups (P < 0.05), and there was no significant difference between the remaining three groups. Conclusion The SUVmax of axillary lymph nodes decreased over the period after the COVID-19 vaccination and no significant difference was found after 3 weeks of vaccination. Therefore, it is recommended to record COVID-19 vaccination information before examination.

Optimization of Flushing through Correlation Analysis between the Number of Flushing and Residual Activity in PET/CT (PET/CT에서 최적의 플러싱횟수를 위한 잔류방사능과의 상관분석)

  • Woo-Yeong Choi;Yeong-Sik Jee;Chang-Yong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.701-707
    • /
    • 2023
  • In PET/CT, the injection volume of 18F-FDG directly affects the SUV(standard uptake value), which can affect the reading results. Therefore, it is important to inject the correct dose value of 18F-FDG. In this study, we performed the correlation between the residual radioactivity remaining in the syringe and catheter insertion device according to the number of flushing during 18F-FDG injection. CRC-25R dose calibrator, catheter insertion devices, 3 cc syringes and 50 cc physiological saline were used in this study, and the results were statistically analyzed. As a result, the total residual radioactivity of the syringe and catheter insertion device remained the highest at 5.84% after two flushing, and the least remained at 1.49% after five flushing. The correlation analysis results showed that the number of flushing had a negative correlation with the residual radioactivity of the syringe at -0.436 and the catheter insertion device at -0.300. As a result of one-way distributed analysis of the average according to the number of flushing, the syringe showed a significant decrease at 4 times, and the catheter insertion device showed a significant decrease at 5 times. However, considering that an average of 0.8% remains in the case of catheter insertion devices, four time flushing seems to be the most appropriate.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

Difference in F-18 FDG Uptake According to the Patterns of CT-Based Diagnosed Pulmonary Lymphangitic Carcinomatosis in Patients with Lung Cancer (폐암환자에 있어 CT상으로 진단된 폐림프관성암종증의 형태에 따른 F-18 FDG 섭취의 차이)

  • Jun, Sung-Min;Kim, Yong-Ki;Kim, In-Ju;Kim, Seong-Jang;Nam, Hyun-Yeol;Kim, Bum-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.292-300
    • /
    • 2008
  • Purpose: Our purpose was to evaluate F-18 FDG uptake in pulmonary lymphangitic carcinomatosis (PLC) according to CT findings and histology of lung cancer. Materials and Methods: Thirty-three lung cancer patients with PLC were enrolled in this retrospective study. All the patients had a CT-based diagnosis of PLC. Chest CT findings of PLC were classified on the basis of involvement of axial interstitium. We categorized the involvement of axial interstitium as group 1, and the involvement of peripheral interstitium only as group 2. Visual and semiquantitative analyses by F-18 FDG PET/CT were performed in the PLC lesions. At first, we analyzed the F-18 FDG uptake in the PLC by visual assessment. If abnormal uptake was seen in the PLC, we drew regions of interest in the PLC lesions to obtain the maximum SUVs (maxSUVs). Results: Of the 33 patients, 22 had abnormal F-18 FDG uptake in the visual assessment. There was no significant difference in the frequency of abnormal F-18 FDG uptake between group 1 and group 2 (p=0.17), although the frequency of group 1 tended to be higher than group 2 (15/19 (78.9%) in group 1, 7/14 (50.0%) in group 2). However, group 1 had a higher maxSUV than group 2 (p<0.01, group 1: $2.9{\pm}1.4$, group 2: $1.5{\pm}0.6$). There was no significant difference in the frequency of abnormal F-18 FDG uptake and maxSUV among the histology of the lung cancers. Conclusion: The involvement of axial interstitium in the PLC by lung cancer has a higher maxSUV than the involvement of only peripheral interstitium.