• Title/Summary/Keyword: FD

Search Result 865, Processing Time 0.024 seconds

Link selection based on switching between full-duplex and half-duplex modes

  • Kim, Sangchoon
    • ETRI Journal
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Multiple-input multiple-output systems can achieve a full sum rate (SR) via full duplex (FD). However, its performance is degraded by self-interference (SI) that occurs between the transmitter and receiver at the same node and thus is constrained by error floors. Conversely, half duplex (HD) can avoid the SI albeit at lower spectral efficiency, and the slope of its error curve is determined by the diversity order. In this study, a link selection scheme based on switching between FD and HD is examined as a simple method to improve the bit error rate (BER) performance of FD systems. In the proposed link selection algorithm, either FD or HD is selected based on the received minimum distance and signal-to-interference plus noise ratio. Simulation results indicate that the proposed hybrid FD/HD switching system offers significant BER performance improvement when compared with that of the conventional FD and FD based on only the received minimum distance under the same fixed SR. Under relatively sufficient SI cancellation, it is demonstrated to outperform the HD with a diversity advantage in low and medium signal-to-noise ratio region.

Radio Propagation Model and Spatial Correlation Method-based Efficient Database Construction for Positioning Fingerprints (위치추정 전자지문기법을 위한 전파전달 모델 및 공간상관기법 기반의 효율적인 데이터베이스 생성)

  • Cho, Seong Yun;Park, Joon Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.7
    • /
    • pp.774-781
    • /
    • 2014
  • This paper presents a fingerprint database construction method for WLAN RSSI (Received Signal Strength Indicator)-based indoor positioning. When RSSI is used for indoor positioning, the fingerprint method can achieve more accurate positioning than trilateration and centroid methods. However, a FD (Fingerprint Database) must be constructed before positioning. This step is a very laborious process. To reduce the drawbacks of the fingerprint method, a radio propagation model-based FD construction method is presented. In this method, an FD can be constructed by a simulator. Experimental results show that the constructed FD-based positioning has a 3.17m (CEP) error. In this paper, a spatial correlation method is presented to estimate the NLOS(Non-Line of Sight) error included in the FD constructed by a simulator. As a result, the NLOS error of the FD is reduced and the performance of the error compensated FD-based positioning is improved. The experimental results show that the enhanced FD-based positioning has a 2.58m (CEP) error that is a reasonable performance for indoor LBS (Location Based Service).

Field Dependence/ Independence and the Performance of the Online Searcher (정보검색자의 인지양식이 정보검색에 미치는 영향)

  • Yoo Jae Ok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.19
    • /
    • pp.189-241
    • /
    • 1990
  • This study identified cognitive styles of online searchers in terms of Field Dependence (FD) and Field Independence (FI) dimension and determined whether searching performance was affected by FD / FI cognitive differences between online searchers and the extent to which searching performance was affected by the FD / FI dimension of cognitive style. This study used a quasi experimental design with 41 student subjects using the Lockheed DIALOG system and ERIC ONT AP database. Cognitive styles of student subjects were measured by using GEFT (Group Embedded Figure Test) and the subjects were divided into two cognitive groups- FD and FI based on the GEFT scores. Each subject was assigned two predetermined searches which had different search goals-a 'high precision search' and a 'high recall search.' Search performance of the two cognitive groups on the two problems was compared in order to see how these two groups responded to achieving different search goals in terms of search strategy, search inputs, and resulting search outputs. The major findings of this study were: 1. The pattern of approaching a search problem regardless of whether it was a high precision search or a high recall search was not significantly different between the two cognitive groups. 2. The FI group tended to use significantly more terms for the high recall search than the FD group but slightly less time than the FD group. However, significant differences in connect time between the two groups were not revealed. 3. For both search problems the FI group achieved a significantly higher success rate than the FD group. The FI group were significantly more successful searchers than the FD group. As for unit / cost, although the FI group were more cost effective than those of the FD group for both searches, these differences were too small to be statistically significant. 4. Mean differences of the search performance variables between the FD / FI groups were consistent across the two types of search questions. The FI group seemed to be equally effective for both types of search questions. In conclusion, the differences found in number of terms used and success rate between the two cognitive groups apparently resulted from different cognitive styles.

  • PDF

Antioxidant Activities of Extracts from Parts of Styela clava (미더덕의 부위별 추출물의 항산화 활성)

  • Jung, Eun-Sil;Park, Eun-Ju;Park, Hae-Ryong;Lee, Seung-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.12
    • /
    • pp.1674-1678
    • /
    • 2008
  • Antioxidant activities of extracts from parts of Styela clava (Korean name: miduduk) were evaluated. Each part of S. clava-fresh (FR) or freeze dried (FD) state-was extracted by four different solvents (methanol, ethanol, acetone, and water). Antioxidant activity of the extracts was determined by radical scavenging activity assay and reducing power assay. Radical scavenging activity was the highest in distilled water extract of FD flesh, and reducing power was the highest in acetone extract of FR flesh. These results indicate that the antioxidant property of S. clava is variable with the structural part, type of extraction solvent, and drying condition.

A novel nicotinoyl peptide, nicotinoyl-LVH, for collagen synthesis enhancement in skin cells

  • Kim, Hyoung Shik;Ryu, Seung Hwan;Kim, Hye In;Cho, Seung Hee;Lee, Jeong Hun;Han, Byung Suk;Lee, Kyung Rok;Moh, Sang Hyun
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.3
    • /
    • pp.239-242
    • /
    • 2016
  • A novel Nicotinoyl fused peptide, Nicotinoyl-LVH, was synthesized by solid phase peptide synthesis method, purified, and tested in cultured skin cells. Nicotinoyl-LVH enhanced the expression level of collagen mRNA and its fragments in fibroblasts. These data show that this novel Nicotinoyl peptide is a promising biomaterial in the anti-aging functional cosmetic market.

A Study on Automotive Diagnostic System using CAN, CAN FD, FlexRay (CAN, CAN FD, FlexRay를 이용한 자동차용 진단시스템에 관한 연구)

  • Son, Chang-Koan;Oh, Se-Chun;Kim, Eui-Ryong;Kim, Sin-Ryeong;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.311-318
    • /
    • 2016
  • Recent vehicles are using car internal network for various purposes such as vehicle control, diagnostic functions, and ECU program upgrade. Currently CAN and FlexRay are the most representative networks. In the next-generation network, the use of CAN FD and car ethernet is actively studied. In this paper, we aimed to compare and evaluate the diagnostic function and the program of the ECU from the upgrade view on characteristics related to download time for each network when CAN, CAN FD, and FlexRay network are applied. As a result of the simulation, it was possible to determine that the CAN FD network is currently the most suitable for the next-generation network by suppressing other networks in terms of cost performance even under conditions of 500 Kbps and 2 Mbps which are practically usable speeds.

Antioxidant Activities and Properties of Freeze-Dried Coffee on Lard (돈지에 대한 동결건조 커피의 항산화력 발현특성)

  • Rhi, Ju-Won;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.348-352
    • /
    • 1995
  • The antioxidant activities and properties of freeze-dried(FD) coffee were examined. Aqueous solution of FD coffee showed antioxidant activity on lard, and the antioxidant effect increased with increasing the addition of the aqueous solution. In contrast, FD coffee powder did not showed antioxidant activity on lard. The antioxidant activities of aqueous FD coffee solution of different solid contents were closely correlated with the water activity(Aw). Aqueous FD coffee solution with high Aw(over 0.98) showed strong antioxidant activity. Emulsifiers added to lard did not change the antioxidant activities of aqueous FD coffee solution. The lard that aqueous FD coffee solution was removed from by centrifuging had an antioxidant activity as the lard with aqueous FD coffee solution did. The spectrophotometry test showed that unidentified nonpolar components of FD coffee were introduced into lard.

  • PDF

Forbush Decreases Observed by the LRO/CRaTER

  • Sohn, Jongdae;Oh, Suyeon;Yi, Yu;Kim, Eojin;Lee, Joo-Hee;Spence, Harlan E.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.120.1-120.1
    • /
    • 2012
  • The Lunar Reconnaissance Orbiter (LRO) launched on June 16, 2009 has six experiments including of the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) onboard. The CRaTER instrument characterizes the radiation environment to be experienced by humans during future lunar missions. The CRaTER instrument measures the effects of ionizing energy loss in matter specifically in silicon solid-state detectors due to penetrating solar energetic protons (SEP) and galactic cosmic rays (GCRs) after interactions with tissue-equivalent plastic (TEP), a synthetic analog of human tissue. The CRaTER instrument houses a compact and highly precise microdosimeter. It measures dose rates below one micro-Rad/sec in silicon in lunar radiation environment. Forbush decrease (FD) event is the sudden decrease of GCR flux. We use the data of cosmic ray and dose rates observed by the CRaTER instrument. We also use the CME list of STEREO SECCHI inner, outer coronagraph and the interplanetary CME data of the ACE/MAG instrument.We examine the origins and the characteristics of the FD-like events in lunar radiation environment. We also compare these events with the FD events on the Earth. We find that whenever the FD events are recorded at ground Neutron Monitor stations, the FD-like events also occur on the lunar environments. The flux variation amplitude of FD-like events on the Moon is approximately two times larger than that of FD events on the Earth. We compare time profiles of GCR flux with of the dose rate of FD-like events in the lunar environment. We figure out that the distinct FD-like events correspond to dose rate events in the CRaTER on lunar environment during the event period.

  • PDF

Characterization of Isoflavone in Callus Culture from Glycine max (L.) Merr. Phytoplacenta (대두 태좌조직의 캘러스배양에 의한 Isoflavone 동정)

  • Kang, Hyo-Seok;Min, Ji-Aee;Jung, Hae-Soo;Lee, Jeong-Hun;Shin, Dong-Sun;Kim, Eun-Ae;Kim, Young-Jun;Moh, Sang-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.235-238
    • /
    • 2012
  • 본 연구는 Glycine max (L.) Merr.의 태좌부위를 순수 분리하여 callus 세포를 유도하고 2차 대사산물인 isoflavone류에 속하는 daidzein의 생산성을 증진시킬 수 있는 방법을 찾는데 있다. 배양된 callus를 다양한 용매를 사용하여 추출하고, 추출물을 액체 크로마토그래피로 분석해 daidzein 함량의 차이를 확인하였다. 또한 핵자기공명분광법으로 50% 에탄올 추출물 내에 daidzein이 함유되어 있음을 증명하였다.

  • PDF

A Study on the Characteristics of Two-Step-Flow-Control Fluidic Device (2단 유량제어 Fluidic Device의 특성에 관한 연구)

  • Cho, Bong-Hyun;Bae, Yoon-Yeong;Park, Jong-Kyun;Yoo, Seong-Yeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.53-61
    • /
    • 2001
  • Vortex type Fluidic Device(FD) which is installed at the bottom of Safety Injection Tank(SIT) controls the discharge flow rate from the tank. In case of loss of coolant accident the injection water flows into primary system in two steps; initial high flow rate for certain period of time and subsequent low flow rate. By two-step control of the discharge flow rate, FD can ensure the effective use of water in the tank. A small-scale FD has been tested to obtain a required flow characteristics maintaining full pressure and height of prototype, which are the major contributing parameters. Through the testing of many different arrangements of internal geometry of FD, most appropriate one was selected and its performance data was obtained. As characteristics of FD, time dependent Euler number, flow rate and pressure are presented and discussed. Also a method to predict the full size FD is presented.

  • PDF