• 제목/요약/키워드: FC-72

검색결과 59건 처리시간 0.023초

히트싱크 미세채널 내의 입구유동 영역에서의 단상 열유동 특성에 관한 연구 (Study on Single-Phase Thermal and Hydrodynamic Characteristics in the Entry Region of a Mini-Channel Heat Sink)

  • 장용희;김용찬;이규정
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1007-1016
    • /
    • 2006
  • Although the advance in electronic technology enables a large number of circuity to be packed in a small volume, it is simultaneously required to remove the high heat load produced by them. In this study, the heat transfer and pressure drop characteristics of a mini-channel heat exchanger, which is designed for liquid cooling of electronic components, are investigated by varying operating conditions. Water and FC-72 were used as working fluids. The mini-channel heat exchanger was made with circular shape channels having din-meters of 2, 3, and 4 mm in regular intervals, and the channel length was 100 mm. The header and inlet guide pathway to provide uniform inflow were attached at the inlet of the test section. Copper block including the heaters was attached at the sidewall of the test section as a heat source, which provided the heat flux from 5 to $15W/cm^2$. The entrance effects enhanced the heat transfer coefficient in the mini-channel significantly. In addition, the single-phase pressure drop in the mini-channel was very similar to that predicted by the laminar flow correlation except that the transition Re decreased due to flow instability in the entrance region.

80kW급 고분자 전해질 연료전지의 공기공급계(터보 블로워) 개발 (Development of air supply system(Turbo blower) for 80kW PEM fuel cell)

  • 이희섭;김창호;이용복
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.67-72
    • /
    • 2006
  • Blower as an air supply system is one of the most important BOP (Balance of Plant) system fur FCV(Fuel Cell Vehicle). For generating and blowing compressed air, the motor of air blower consumes maximum 25% of net power and fuel cell demands a clean air. Considering the efficiency of whole FCV, low friction lubrication of high speed rotor is needed. For the purpose of reducing electrical power and supplying clean air to Fuel cell, oil-free air foil bearings are applied at the each side of brushless motor (BLDC) as journal bearings which diameter is 50mm. The normal power of driving motor has 1.7kW with the 30,000rpm operating range and the flow rate of air has maximum 160 SCFM. The impeller of blower was adopted a mixed type of centrifugal and axial which has several advantages for variable operating condition. The performance of turbo-blower and parameters of air foil bearings was investigated analytically and experimentally. From this study, the performance of the blower was confirmed to be suitable far 80kw PEM FC.

  • PDF

저온 비등 팽창유체와 고점성 유체마개를 이용한 고출력 저전력형 마이크로 분사기 (High-impulse, Low-Power Microthruster using Liquid Propellant with High-Viscosity Fluid Plug)

  • 김상욱;강태구;조영호
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.868-874
    • /
    • 2002
  • A high-impulse, low-power, digital microthruster has been developed using low-boiling-temperature liquid propellant with high-viscosity fluid plug. The viscous fiction force of the fluid plug increases the blast pressure and the low-boiling-temperature liquid propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of 7$\times$13$\times$1.5㎣. A digital output impulse bit of 6.4$\times$10$^{-8}$ Nsec has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional multiple-shot microthruster.

저전력소비, 고출력, 연발형 마이크로 분사기의 설계, 제작 및 성능 시험 (Design, Fabrication and Performance Testing of a High-impulse, Low-Power Microthruster using Liquid Propellant with High Viscous Fluid Plug)

  • 김상욱;강태구;조영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.59-63
    • /
    • 2001
  • A high-impulse, low-power, continuous-shot microthruster has been developed using low boiling temperature liquid-propellant with high viscous fluid-plug. The viscous friction force of the fluid-plug increases the blast pressure and the low boiling temperature liquid-propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of $7{\times}13{\times}1.5mm^{3}$. A continuous output impulse bit of $6.4{\times}10^{-8}N{\cdot}sec$ has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional continuous microthruster.

  • PDF

휴대용 컴퓨터내의 이상유동 냉각시스템을 이용한 모사칩의 열성능에 관한 연구 (A Study on Thermal Performance of Simulated Chip using a Two Phase Cooling System in a Laptop Computer)

  • 박상희;최성대
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.53-59
    • /
    • 2011
  • In this study, a two-phase closed loop cooling system is desinged and tested for a laptop computer using a FC-72. The cooling system is characterized by a parametric study which determines the effects of existence of a boiling enhancement microstructure, initial system pressure, volume fill ratio of coolant and inclination angle of condenser on the thermal performance of the closed loop. Experimental data show the optium condition when the volume ratio of working fluid is 70%, the pump flowing is 6ml/min, and the inclination angle of condenser is $0^{\circ}$. This research shows the maximum values which can dissipate 33W of chip power with a chip temperature maintained at $95^{\circ}C$.

마이크로 히터에서의 기포 생성에 관한 실험적 연구 (An Experimental Study on Bubbles Growth on Microheater)

  • 고승현;김신규;김호영;장영수;이윤표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1909-1914
    • /
    • 2003
  • Bubble growth on microheater has been experimentally investigated in this study. The experiment was performed using platinum micro heaters having dimensions of $100{\times}10{\times}0.2{\mu}m^3$ with constant heat flux. A high speed video camera was used to observe bubble growth at 250 frames per second. Microheater temperature was measured at the rate of 300Hz with a data acquisition system. When heater temperature was $139^{\circ}C$ a bubble was nucleated in the liquid FC-72. The temperature profiles and the high speed camera images were combined to explain heat transfer and bubble growth on microheater.

  • PDF

Cold plate를 이용한 휴대용 컴퓨터 냉각 시스템의 열성능에 관한 연구 (A Study on Thermal Performance of Cooling System for a Laptop Computer Using a Cold Plate)

  • 박상희;조남해;최성대
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.83-89
    • /
    • 2009
  • This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.

  • PDF

사각 마이크로 히터위에서의 기포의 형성 및 거동 (Bubble Nucleation and Behavior on Square Micro Heaters)

  • 정정열;곽호영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1464-1469
    • /
    • 2004
  • In this study, micro square heaters having dimensions of $65{\times}65{\mu}m^2$and $100{\times}100{\mu}m^2$ were fabricated and bubble nucleation experiments on the heaters were performed. Bubble nucleation temperature was also measured using a bridge circuit and the photographs of bubble nucleation and subsequent growth were taken by a camera with a flash unit. Measured bubble nucleation temperatures were found to be closer to the superheat limit of working fluid (FC-72). Also quasi-1D analyses for the square heaters were performed. The quasi-1D analysis yielded proper temperature distribution of the square heater at steady state, however failed to predict the temperature rise up to the steady state. Similar time dependent temperature can be obtained with proper value of thermal diffusivity. For the $100{\times}100{\mu}m^2$ square heater, nucleation of several bubbles was observed while only one bubble was observed to be nucleated on $65{\times}65{\mu}m^2$ heater.

  • PDF

수평 다채널에서의 압력강하에 관한 새로운 상관식 (A New Correlation on Pressure Drop in Horizontal Multi Channels)

  • 최용석;임태우;유삼상;김환성
    • 수산해양교육연구
    • /
    • 제28권5호
    • /
    • pp.1273-1279
    • /
    • 2016
  • Flow boiling pressure drop in multi channels was experimently investigated. The multi channel has a width and depth of 0.45 and 0.2mm respectively, and comprises 15 parallel channels. The measured total pressure drop is expressed by the sum of the frictional pressure drop and acceleration pressure drop. In order to predict the total pressure drop, it is required to obtain the correct frictional pressure drop. The existing correlations to predict the frictional pressure were compared with measured frictional pressure drop. The new correlation was developed in the form of the Chisholm correlation. It was related to Chisholm Constant B as a function of Martinelli parameter. The new correlation predicted the experimental data within a mean absolute error of 5.5%.

밭 작물의 최적관개수준과 계획용수량 산정 (The Optimum Irrigation Level and the Project Water Requirement for Upland Crops)

  • 윤학기;정상옥;서승덕
    • 한국농공학회지
    • /
    • 제32권1호
    • /
    • pp.72-86
    • /
    • 1990
  • This study was carried out to get the basic information of irrigation plans for upland crops such as the optimum irrigation level and the project water requirement. Red peppers and cucumbers were cultivated in PVC pot lysimeters filled with 60cm deep clay loam soil. Four tensiometers were installed in each pot to measure the soil water pressure head. Six levels of irrigation were used. The results obtained from this study are summarized as follows: 1.The optimum irrigation level. The irrigation level of FC-PF2.7 was found to be the optimum level for both red pepper and cucumber with respect to the yield and the weight per fruit. In case of FC-PF2.7, total ET during the irrigation period were 1005.2mm for red pepper, and 429.6mm for cucumber, respectively. 2.soil moisture extraction patterns. Average soil moisture extraction patterns (SMEP)during the irrigation period were from 1st soil layer 43% : 32% : 16% : 9% for red pepper and 39% : 34% : 15% : 12% for cucumber, respectively. The extraction ratio of the upper soils showed very large values during the early stage of growth and decreased largely during the middle stage, and became larger in the last stage. 3.The project water requirement. Among the reference crop evapotranspiration(ETo) computation methods presented by FAO, the Penman method was found to be the best. The effective rainfall was computed by a modified USDA-SCS curve number equation. Availability ratios of the total rainfall during irrigation season were 59.2% for red pepper and 48.9% for cucumber, respectively. Net project water requirement of design year are 837.3mm for red pepper. and 502.Smm for cucumber, respectively.