• 제목/요약/키워드: FAC

검색결과 326건 처리시간 0.036초

Effects of dietary Antrodia cinnamomea fermented product supplementation on antioxidation, anti-inflammation, and lipid metabolism in broiler chickens

  • Lee, M.T.;Lin, W.C.;Lin, L.J.;Wang, S.Y.;Chang, S.C.;Lee, T.T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1113-1125
    • /
    • 2020
  • Objective: This study was investigated the effects of dietary supplementation of Antrodia cinnamomea fermented product on modulation of antioxidation, anti-inflammation, and lipid metabolism in broilers. Methods: Functional compounds and in vitro antioxidant capacity were detected in wheat bran (WB) solid-state fermented by Antrodia cinnamomea for 16 days (FAC). In animal experiment, 400 d-old broiler chickens were allotted into 5 groups fed control diet, and control diet replaced with 5% WB, 10% WB, 5% FAC, and 10% FAC respectively. Growth performance, intestinal microflora, serum antioxidant enzymes and fatty acid profiles in pectoral superficial muscle were measured. Results: Pretreatment with hot water extracted fermented product significantly reduced chicken peripheral blood mononuclear cells death induced by lipopolysaccharide and 2,2'-Azobis(2-amidinopropane) dihydrochloride. Birds received 5% and 10% FAC had higher weight gain than WB groups. Cecal coliform and lactic acid bacteria were diminished and increased respectively while diet replaced with FAC. For FAC supplemented groups, superoxide dismutase (SOD) activity increased at 35 days only, with catalase elevated at 21 and 35 day. Regarding serum lipid parameters, 10% FAC replacement significantly reduced triglyceride and low-density lipoprotein level in chickens. For fatty acid composition in pectoral superficial muscle of 35-d-old chickens, 5% and 10% FAC inclusion had birds with significantly lower saturated fatty acids as compared with 10% WB group. Birds on the 5% FAC diet had a higher degree of unsaturation, followed by 10% FAC, control, 5% WB, and 10% WB. Conclusion: In conclusion, desirable intestinal microflora in chickens obtaining FAC may be attributed to the functional metabolites detected in final fermented product. Moreover, antioxidant effects observed in FAC were plausibly exerted in terms of improved antioxidant enzymes activities, increased unsaturated degree of fatty acids in chicken muscle and better weight gain in FAC inclusion groups, indicating that FAC possesses promising favorable mechanisms worthy to be developed.

CANDU형 원전 2차 배관의 침부식 감육 관리방법에 관한 연구 (A Study on Managing of Metal Loss by Flow-Accelerated Corrosion in the Secondary Piping of CANDU Nuclear Plants)

  • 심상훈;송정수;윤기봉;황경모;진태은;이성호
    • 에너지공학
    • /
    • 제11권1호
    • /
    • pp.18-25
    • /
    • 2002
  • 침부식 (FAC, Flow-Accelerated Corrosion)에 의한 감육 문제는 원자력 발전소 배관관리에 있어서 매우 중요하다. 특히 FAC는 배관 내부 유체의 pH, 용존산소 농도, 유체 온도, 유속 및 습증기 분율 등과 배관의 형상 및 재료 등의 특정 조건에서만 발생하므로, FAC 문제를 관리하기 위해서는 체계적인 접근이 필요하다. 본 연구에서는 국내 특정 CANDU원전의 2차계통 배관을 대상으로 관련 데이터베이스 구축, 구축된 데이터베이스를 이용한 FAC감육율의 예측 및 배관 잔여수명의 평가 등을 수행하였다. 또한 FAC 발생기구 및 FAC에 영향을 주는 요인에 대해서도 조사하였다. 습분분리기와 플래시탱크 사이 배관 라인의 해석 예로부터 FAC 문제를 관리하는 방안을 제시하였다. 제시된 방안은 국내 다른 원자력발전소의 배관 관리에도 활용될 수 있을 것이다.

절화 장미 'Brut'의 절화수명에 미치는 유리염소의 항균효과 (Antimicrobial Effect of Free Available Chlorine on Postharvest Life of Cut Rose 'Brut')

  • 이영분;김완순
    • 원예과학기술지
    • /
    • 제31권3호
    • /
    • pp.317-321
    • /
    • 2013
  • 본 연구는 유리염소(free available chlorine, FAC)의 항균 효과가 장미 'Brut' 품종의 절화수명에 미치는 영향을 알아보고자 실시하였다. 절화수명 연장처리는 보존용액처리와 침지처리로 구분하였다. FAC 보존용액처리는 FAC 단용처리(Cl 0, 10, 20, $40mg{\cdot}L^{-1}$)와 sucrose와의 혼용처리(Cl $10mg{\cdot}L^{-1}$ + sucrose 2%, Cl $20mg{\cdot}L^{-1}$ + sucrose 2%, Cl $40mg{\cdot}L^{-1}$ + sucrose 2%)로 구분하여 실시하였고, FAC 침지처리는 Cl 100, 200, $400mg{\cdot}L^{-1}$에서 10초 동안 실시하였다. 장미 절화수명은 Cl $20mg{\cdot}L^{-1}$ 보존용액처리에서 12일로 가장 길었고, Cl $400mg{\cdot}L^{-1}$ 침지처리에서 11일로 나타났으며, 이들 처리는 대조구보다 4-5일 연장효과를 나타냈다. 생체중과 용액흡수율 역시 Cl $20-40mg{\cdot}L^{-1}$ 보존용액처리에서 가장 높았다. 최대 8일간 지속된 FAC 항균효과는 sucrose 혼용으로 상쇄되었다. FAC의 잔존량은 처리 2일째 sucrose 첨가 시 88%가 감소한 반면, Cl $20mg{\cdot}L^{-1}$ 단독 처리에서는 15%만이 감소하였다. 이상의 결과에서 장미 절화수명 연장에 FAC의 항균효과가 인정되었다.

유동가속부식에 영향을 미치는 수화학 인자 : pH, 용존산소, 하이드라진 (Effect of Water Chemistry Factors on Flow Accelerated Corrosion : pH, DO, Hydrazine)

  • 이은희;김경모;김홍표
    • Corrosion Science and Technology
    • /
    • 제12권6호
    • /
    • pp.280-287
    • /
    • 2013
  • Flow accelerated corrosion(FAC) of the carbon steel piping in pressurized water reactors(PWRs) has been major issue in nuclear industry. Severe accident at Surry Unit 2 in 1986 initiated the worldwide interest in this area. Major parameters influencing FAC are material composition, microstructure, water chemistry, and hydrodynamics. Qualitative behaviors of FAC have been well understood but quantitative data about FAC have not been published for proprietary reason. In order to minimize the FAC in PWRs, the optimal method is to control water chemistry factors. Chemistry factors influencing FAC such as pH, corrosion potential, and hydrazine contents were reviewed in this paper. FAC rate decreased with pH up to 10 because magnetite solubility decreased with pH. Corrosion potential is generally controlled dissolved oxygen (DO) and hydrazine in secondary water. DO increased corrosion potential. FAC rate decreased with DO by stabilizing magnetite at low DO concentration or by formation of hematite at high DO concentration. Even though hydrazine is generally used to remove DO, hydrazine itself thermally decomposed to ammonia, nitrogen, and hydrogen raising pH. Hydrazine could react with iron and increased FAC rate. Effect of hydrazine on FAC is rather complex and should be careful in FAC analysis. FAC could be managed by adequate combination of pH, corrosion potential, and hydrazine.

Can Observational Gait Assessment Tools be used to Assess Independent Walking in Stroke Patients?

  • Ju, Sung-Kwang
    • 대한물리의학회지
    • /
    • 제17권1호
    • /
    • pp.11-20
    • /
    • 2022
  • PURPOSE: A gait assessment is an important component of the rehabilitation process, and observational gait assessment (OGA) is used routinely in clinical settings. This study examined the association of OGA tools with the independent walking ability in stroke patients to determine a cutoff value of the OGA tool according to independence levels of stroke patient gait. METHODS: Two hundred ten hemiparetic stroke patients participated in the study. The independence of gait was identified using the Functional Ambulation Category (FAC) classifications. The walking ability was assessed using OGA tools (Rivermead Visual Gait Assessment [RVGA], Wisconsin Gait Scale [WGS], Tinetti Gait Scale [TGS], and Functional Gait Analysis [FGA]). RESULTS: Stepwise multiple regression analysis showed that among the OGA tools, the FGA correlated with the FAC. The FGA explained approximately 77% of the variance in FAC. In distinguishing the independence levels, the cutoff values were as follows: between FAC 1 and FAC 0 was .5 points; between FAC 2 and lower levels, 5.5; between FAC 3 and lower levels, 11.5; between FAC 4 and lower levels, 14.5; and between FAC 5 and lower levels, 18.5. Items 1, 2, 3, and 10 were identified as explaining most of the variance in the FGA in the stepwise multiple regression. CONCLUSION: The present study found that the FGA is an assessment tool related to the level of gait independence after stroke. Furthermore, the FGA total score can serve as an index of the increase in independence level after stroke.

Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) detection

  • Chang, Seung-Cheol;Park, Deog-Su
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.449-456
    • /
    • 2007
  • The work described in this study concerns the development of a disposable amperometric sensor for the electrochemical detection of a well-known aqueous pollutant, free available chlorine (FAC). The FAC sensor developed used screen printed carbon electrodes (SPCEs) coupled with immobilised syringaldazine, commonly used as an indicator in photometric FAC detection, which was directly immobilised on the surface of SPCEs using a photopolymer PVA-SbQ. To enable in-field analysis of FAC, a prototype hand-held electrochemical analyzer has been developed to withstand the environment with its rugged design and environmentally sealed connections; it operates from two PP3 (9 volt) batteries and is comparable in accuracy and sensitivity to commercial bench top systems. The sensitivity of the FAC sensor developed was $3.5{\;}nA{\mu}M^{-1}cm^{-2}$ and the detection limit for FAC was found to be $2.0{\;}{\mu}M$.

Assessment of flow-accelerated corrosion-induced wall thinning in SA106 pipes with elbow sections

  • Seongin Moon;Jong Yeon Lee;Kyung-Mo Kim;Soon-Woo Han;Gyeong-Geun Lee;Wan-Young Maeng;Sebeom Oh;Dong-Jin Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1244-1249
    • /
    • 2024
  • A combination of flow-accelerated corrosion (FAC) tests and corresponding computational fluid dynamics (CFD) tests were performed to determine the hydrodynamic parameters that could help predict the highly susceptible location to FAC in the elbow section. The accelerated FAC tests were performed on a specimen containing elbow sections fabricated using commercial 2-inch carbon steel pipe. The tests were conducted at flow rates of 9 m/s under the following conditions: water temperature of 150 ℃, dissolved oxygen <5 ppb, and pH 7. Thickness reduction of the specimen pipe due to FAC was measured using ultrasonic testing. CFD was conducted on the FAC test specimen, and the turbulence intensity, and shear stress were analyzed. Notably, the location of the maximum hydrodynamic parameters, that is, the wall shear stress and turbulent intensity, is also the same location with maximum FAC rate. Therefore, the shear stress and turbulence intensity can be used as hydrodynamic parameters that help predict the FAC-induced wall-thinning rate. The results provide a method to identify locations susceptible to FAC and can be useful for determining inspection priority in piping systems.

침부식에 의한 CANDU형 원전 2차측 배관의 감육 예측에 관한 연구 (A Study on Prediction of Metal Loss by Flow-Accelerated Corrosion in the CANDU NPP Secondary Piping Systems)

  • 심상훈;송정수;윤기봉;황경모;진태은;이성호;김위수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.616-621
    • /
    • 2001
  • Flow-accelerated corrosion(FAC) is a phenomenon that results in metal loss from piping, vessels, and equipment made of carbon steel. FAC occurs only under certain conditions of flow, chemistry, geometry, and material. Unfortunately, those conditions are in much of the high-energy piping in nuclear and fossil-fueled power plants. Also, for domestic NPP secondary pipings whose operating time become longer, more evidences of FAC have been reported. The authors are studying on FAC management using CHECWORKS, computer code developed by EPRI. This paper is on the prediction results of metal loss by FAC in the one of CANDU type NPP secondary piping systems.

  • PDF