• Title/Summary/Keyword: F0 Range

Search Result 1,444, Processing Time 0.026 seconds

Application of Canadian Council of Ministers of the Environment Water Quality Index (CCME WQI) in Daecheong Reservoir using Automatic Water Quality Monitoring Data (대청호 내 실시간 수질측정자료를 이용한 CCME WQI의 적용)

  • Lim, Byungjin;Hong, Jiyoung;Yeon, Insung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.796-801
    • /
    • 2010
  • Water quality index (WQI) can be a great tool that allows experts to translate large amount of complex water quality data into a format more easily understood by the public and policy makers. Canadian Council of Ministers of the Environment Water Quality Index (CCME WQI) can be calculated with the three factors (Scope: $F_1$, Frequency: $F_2$, Amplitude: $F_3$). After all, the WQI for a specific site is produced as a number between 0 to 100; the scale is also divided into five categories, i.e., Excellent, Good, Fair, Marginal and Poor. The WQI was found to be highly related to Chl-a, pH, temperature among the collected items. When the more input parameters were used, the range of variation generally became smaller. $F_3$ among the factors of WQI was influenced by algae. It showed a similar variation tendency between WQI and algal bloom in 2008.

Design of Cellular Power Amplifier Using a SifSiGe HBT

  • Hyoung, Chang-Hee;Klm, Nam-Young;Han, Tae-Hyeon;Lee, Soo-Min;Cho, Deok-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.236-238
    • /
    • 1997
  • A cellular power amplifier using an APCVD(Atmospheric Pressure Chemical Vapor Deposition)-grown SiGe base HBT of ETRI has been designed with a linear simulation CAD. The Si/SiGe HBT with an emitter area of 2$\times$8${\mu}{\textrm}{m}$$^2$typically has a cutoff frequency(f$_{T}$) of 7.0 GHz and a maximum oscillation frequency(f$_{max}$) of 16.1 GHz with a pad de-embedding A packaged power Si/SiGe HBT with an emitter area of 2$\times$8$\times$80${\mu}{\textrm}{m}$$^2$typically shows a f$_{T}$ of 4.7 GHz and a f$_{max}$ of 7.1 GHz at a collector current (Ic) of 115 mA. The power amplifier exhibits a Forward transmission coefficient(S21) of 13.5 dB, an input and an output reflection coefficients of -42 dB and -45 dB respectively. Up to now the III-V compound semiconductor devices hale dominated microwave applications, however a rapid progress in Si-based technology make the advent of the Si/SiGe HBT which is promising in low to even higher microwave range because of lower cost and relatively higher reproducibility of a Si-based process.ess.ess.

  • PDF

Effects of Fluoride Additions on Sintering and Microwave Dielectric Properties of CaWO$_4$ (Fluoride 첨가에 따른 CaWO$_4$의 소결 및 고주파 유전특성)

  • 이경호;김용철;방재철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.127-130
    • /
    • 2002
  • In this study, development of a new LTCC material using a non-glassy system was attempted with respect to reducing the fabrication process steps and cost down. Lowering the sintering temperature can be achieved by liquid phase sintering. For LTCC application, the starting material must have quality factor as high as possible in microwave frequency range. And also, the material should have a low dielectric constant for enhancing the signal propagation speed. Regarding these factors, dielectric constants of various materials were estimated by the Clausius-Mosotti equation. Among them, CaWO$_4$ was tamed out the suitable LTCC material. CaWO$_4$ can be sintered up to 98% of full density at 1200$^{\circ}C$ for 3 hours. It's measured dielectric constant, quality factor, and temperature coefficient of resonant frequency were 10.15, 62880GHz, and -27.8ppm/$^{\circ}C$, respectively. In order to modify the dielectric properties and densification temperature, 0.5∼1.5 wt% LiF were added to CaWO$_4$. LiF addition reduced the sintering temperature/time down to 800$^{\circ}C$/10∼30min due to the reactive liquid phase sintering. Dielectric constant lowered from 10.15 to 9.38 and Q x fo increased up to 92000GHz with increasing LiF content.

  • PDF

The dynamic response of adjacent structures with the shallow foundation of different height and distance on liquefiable saturated sand

  • Jilei Hu;Luoyan Wang;Wenxiang Shen;Fengjun Wei;Rendong Guo;Jing Wang
    • Earthquakes and Structures
    • /
    • v.25 no.2
    • /
    • pp.135-148
    • /
    • 2023
  • The structure-soil-structure interaction (SSSI) effect in adjacent structures may affect the liquefaction-induced damage of shallow foundation structures. The existing studies only analysed the independent effects on the structural dynamic response but ignored the coupling effect of height difference and distance of adjacent structures (F) on liquefied foundations on the dynamic response. Therefore, this paper adopts finite element and finite difference coupled dynamic analysis method to discuss the effect of the F on the seismic response of shallow foundation structures. The results show that the effect of the short structure on the acceleration response of the tall structure can be neglected as F increases when the height difference reaches 2 times the height of the short structure. The beneficial effect of SSSI on short structures is weakened under strong seismic excitations, and the effect of the increase of F on the settlement ratio gradually decreases, which causes a larger rotation hazard. When the distance is smaller than the foundation width, the short structure will exceed the rotation critical value and cause structural damage. When the distance is larger than the foundation width, the rotation angle is within the safe range (0.02 rad).

A Study on the Pain, Fatigue Perceived by Rheumatoid Arthritis Patients (류마티스 관절염 환자가 지각하는 통증과 피로)

  • Yoo, Kyung-Hee
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.9 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the relationship between the level of pain and fatigue in rheumatoid arthritis patients. Method: The subjects for this study were 120 patients registered in S University Hospital, and the period of data collection was from June 20, 2005 to October 15, 2005. Results: The research instruments used in this study were the Graphic Rating Scale of Pain and Fatigue, and the cronbach's ${\alpha}$ of Fatigue scale was .90. In data analysis, SPSSWIN 12.0 program was used for descriptive statistics. The results were as follows. 1) The range of total pain scores was from 10 to 100 and the mean score of the pain in rheumatoid arthritis patients was 53.70. 2) The range of total fatigue scores was from 20 to 58 and the mean score of the fatigue in rheumatoid arthritis patients was 36.04. 3) There was a significant difference in pain according to duration of disease(F=3.934, p<.05). 4) There was a significant difference in fatigue according to duration of disease(F=3.442, p<.05). 5) The level of fatigue was significant correlation with the level of pain in rheumatoid arthritis patients(r=.217, p<.01). Conclusion: The level of fatigue was significant correlation with the level of pain in rheumatoid arthritis patients. Therefore nursing interventions decreasing the pain perceived by rheumatoid arthritis patients are needed to decrease there fatigue levels.

  • PDF

A Study on the Silicon Etching Characteristics in ECR using ${SF_6}/{Cl_2}$ Gas Mixtures (${SF_6}/{Cl_2}$ 혼합비에 따른 실리콘 식각 특성 고찰)

  • 이상균;강승열;권광호;이진호;조경익;이형종
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Etch characteristics of SF6/CI2 electron cyclotron resonance (ECR) plasmas have been investigated. Surface reaction of gas plasma with polysilicon was also analysed using X-ray photoelectron spectroscopy (XPS). At the same time, the relationship between surface reaction and the etched profile of polysilicon was examined using XPS. The etch rate of polysilicon and oxide increases with increasing flow rate of SF6 in the SF6/CI2 gas mixture, and tis selectivity also increase also increase. It was also found that as increasing flow rate of SF6 in the SF6/CI2 gas mixture, the atomic% of chlorine detected at surface region decrease, but F and S contents increase. At the same time, when the mixing ratio of SF6 gas increases, the anisotropy of etched polysilicon is sharply decreased in the 0%~10% range of the SF6 mixing ratio, but is rarely varied in the range over 10%, in spite of the large variations in flow rates. It can be explained that the bonding of S-Si due to SiSx(x$\leq$2) compound formed on the etched surface suppress the formation of Si-Cl and 'or Si-F bonding in the silicon etching.

  • PDF

An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas (일회용 각종 송혈관의 관류압차에 대한 비교실험)

  • Kim, Yo-Han;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

The Physico-chemical Characteristics of Municipal Solid Wastes from Four Different Sources in Daegu City (대구시의 지역별 생활쓰레기 성상 및 특성)

  • No, Sook-Hyun;Lee, Dong-Hoon;Choi, Chung-Ryul;Park, Man;Park, Byung-Yoon;Choi, Jung
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.461-467
    • /
    • 2003
  • This study was conducted to provide the basic information to know reasonable method f3r the removal and treatment of municipal solid wastes(MSWs). MSWs four different sources(apartment residence, commerce, office/industry) in Daegu city were collected, and bulk density, physical composition, moisture, combustible, ash, elements and heating values were investigated. The values of bulk density were at range of 0.30∼0.41ton/m$^3$. The percentages of foods, papers, vinyls/plastics, textiles, rubbers/leathers, metals and glasses/ceramics of wet muncipal solid wastes from three sources except office/industry were at range of 27.3∼46.4%, 21.2∼38.4%, 10.3∼11.9%, 3.8∼5.2%, 0.5∼1.7%, 6.9∼8.7% and 1.9∼2.6% respectively. The percentages of papers, foods, vinyls/plastics, textiles, rubbers/leathers, metals and glasses/ceramics of dry muncipal solid wastes from three sources except office/industry were at range of 21.1∼40.4%, 14.2∼30.1%, 15.2∼17.8%, 4.0∼6.0%, 0.9∼2.8%, 12.2∼14.1% and 3.1∼3.7% respectively. The moisture contents of foods, woods, textiles and papers in wastes were at range of 65.7∼76.2%, 34.6∼50.0%, 22.2∼44.8 and 30.6∼44.4% respectively. The carbon contents of vinyls/plastics, rubbers/leathers, textiles, woods, papers and foods in wastes were at range of 75.88∼79.87%, 58.24∼70.74%, 45.23∼51.63%, 42.29∼45.58%, 40.19∼48.4% and 25.86∼36.25% respectively. The low heating values of foods, papers, woods, textiles, rubbers/leathers and vinyls/plastics by Dulong's law were at range of 178∼1,353kcal/kg, 770∼1,660kcal/kg, 995∼1,629kcal/kg, 2,133∼2,432kca1/kg, 4,200∼7,275 kcal/kg and 6,384∼8,722kcal/kg respectively, and the high heating values of them were at range of 782∼2,056 kcal/kg, 2,459∼3,314kca1/kg, 3,056∼3,592kcal/kg, 4,381∼5,087kca1/kg, 5,005∼8,066kca1/kg and 10,032∼10,739 kcal/kg respectively.

The Role of Excipients in Iontophoretic Drug Delivery: In vitro Iontophoresis of Isopropamide and Pyridostigmine through Rat Skin and Effect of Ion-pair Formation with Organic Anions

  • Shim, Chang-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.3
    • /
    • pp.41-50
    • /
    • 1993
  • The iontophoretic delivery across rat skin of quaternary ammonium salts (isopropamide: ISP, pyridostigmine: PS), which are positively charged over a wide pH range, was measured ill vitro. The study showed that: (a) iontophoresis significantly enhanced delivery of ISP and PS compared to respective passive transport; (b) delivery of ISP and PS was directly proportional to the applied continuous direct current density over the range of $0-0.69\;mA/cm^2;$ (c) delivery of ISP and PS was also proportional to the drug concentration in the donor compartment over the range of $0-2{\time}l0^{-2}M:$ (d) sodium ion in the donor compartment inhibited the drug transport possibly due to decreasing the electric transference number of the drug; (e) delivery of ISP and PS increased as the pH of the donor solution increased over the pH range 2-7 suggesting permselective nature of the epidermis, and inhibition of the transference number of the drugs by hydronium ion; (f) some organic anions such as taurodeoxycholate, salicylate and benzoate which form lipophilic ion-pair complexes with ISP inhibited the delivery of ISP. The degree of inhibition by the organic anions was linearly proportional to the extraction coefficient $(K_e)$ of ISP from the partition system with each counteranion between phosphate buffer (pH 7.4) and n-octanol. For PS, however, taurodeoxycholate, but not salicylate and benzoate inhibited the iontophoretic delivery. It suggests that not only sodium ion and hydronium ion but also the counteranions which form lipophilic ion-pairs with quaternary ammonium drugs are not favorable components in formulating the donor solution of the drugs to achieve an effective iontophoretic delivery.

  • PDF