• 제목/요약/키워드: F-SCAN

검색결과 341건 처리시간 0.029초

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교 (F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET)

  • 배문선;박찬희;조철우;윤석남;양승대;임상무
    • 대한핵의학회지
    • /
    • 제33권1호
    • /
    • pp.65-75
    • /
    • 1999
  • 목적: 종양 환자의 평가에 있어서 초고에너지 조준기를 장착하여 511 keV에 적용시킨 감마카메라로 FDG 전신 평면 영상(FDG W/B scan)을 얻어 충분한 정보를 얻을 수 있는지 알아보고 동시에 같은 카메라로 동시계수 회로를 이용한 양전자 방출 단층촬영(FDG CoDe PET)을 실시하여 그 결과를 비교하였다. 대상 및 방법: F-18 FDG를 이용하여 초고에너지 조준기와 동시계수 양전자 방출영상에 대해 각각 팬텀 실험을 실시하였고, 악성종양이 의심되거나 진단된 환자 14명을 대상으로 FDG 전신 평면 영상과 양전자 방출 단층 영상을 얻어 방사선학적 검사, 임상적 추적관찰, 조직학적 검사 등과 비교하였다. 결과: 평면 영상에서는 해상력 13.1 mm, 민감도 2638 cpm/MBq/ml, 동시계수 영상에서는 공간 해상력 7.49 mm, 민감도 5351 cpm/MBq/ml로 측정되었다. FDG CoDe PET에서 14명의 환자 중 8명에서 FDG의 섭취가 있었다. 두 방법 모두에서 FDG 섭취가 없었던 병변은 모두 CT에서 1 cm 이하 였으나 한 예에서 2 cm 크기의 전이성 림프절을 찾지 못하였다. FDG 섭취를 보였던 병변은 모두 CT상 1.5cm 이상이거나 여러 개가 모여 있는 병변이었다. FDG W/B scan은 FDG CoDe PET와 거의 비슷한 결과를 보였으나 위음성과 위양성이 1예씩 더 있었다. FDG CoDe PET에서 보였던 다수의 폐 결절과 간 결절들이 FDG W/B scan에서 한 예를 제외하고는 모두 발견되었다. 결론: 감마카메라에 의한 FDG 영상들은 악성 종양의 감별, 병기 결정, 추적검사 등에 유용하게 쓰일 수 있을 것으로 간주되며, SPECT 카메라가 널리 보급되어 있으므로 FDG 전신 평면영상과 동시계수 양전자 방출영상은 서로 보완적으로 쓰이면서 FDG의 지역 분배 공급을 통해 기존의 PET를 대신하여 FDG를 이용한 더 많은 임상적 이용 및 영상진단을 가능하게 할 것이다.

  • PDF

그림의 부호화 과정과 신경기제 : fMRI 연구 (Neural Substrates of Picture Encoding: An fMRI Study)

  • 강은주;김희정;김성일;나동규;이경민;나덕렬;이정모
    • 인지과학
    • /
    • 제13권1호
    • /
    • pp.23-40
    • /
    • 2002
  • 본 연구는 fMRI를 이용하여 정상인에 있어서 자극 유형, 특히 그림 자극의 부호화와 관련된 두뇌영역을 확인하고자 하였다. Scan 1에서는 그림 자극의 부호화 과정에 관여하는 두뇌 영역을 화인하기 위하여 어의범주 판단 과정 중에 그림과 단어에 대하여 비교 관찰하였으며 Scan 2에서는 그림자극에 대하여 그림 명명과제와 어의범주 판단과제를 비교하여 과제 유형에 따른 그림의 부호화에 관여하는 두뇌 활성화 영역을 연구하였다. 피험자는 어의범주(인공물/자연물)에 따라 마우스를 눌러 반응하거나(Scan 1) 그림명명이나 범주 소속 여부를 속으로 말하도록(subvocal response)(Scan 2) 요구되었다. 자극의 유형과 무관하게 부호화 중에 좌측 전전두 영역 양측의 두정엽, 그리고 양측의 고차시각 피질 등이 공통적으로 활성화 되었다. 그림보다 단어의 부호화에는 좌측 하 전전두엽, 우측 전측 전전두 영역, 양측의 도(insula), 좌측 두정-측두엽 등 광범위한 언어/개념관련 두뇌 영역에서 더 높은 활성화가 발견되는 반면, 그림의 부호화에는 양측의 고차 시각 영역과 해마방화(parahippocampal gyrus) 영역에서 더 높은 활성화가 관찰되었다. 이는 동일한 어의판단 과제를 수행하는 과정에도 단어는 어의적/언어적 처리가 그림은 지각적 정보처리 및 novelty 관련 정보처리가 서로 다른 해부학적인 영역에 의하여 매개됨을 의미한다. 그림 명명과제나 어의범주 판단과제 모두를 속으로 말하는 수행(Scan 2)은 배측 하 전전두 영역, 즉 Broca영역의 활동 증가를 야기시켰으며, 특히 명명과제 수행에는 어의범주 판단과제를 수행할 때에 비하여 양측의 시각영역에서 더 많은 활성화가 발견되었는데, 이는 대상의 명칭을 인출하는 과정에 고차 시각정보 처리가 더 많이 관여하였을 가능성을 시사한다.

  • PDF

신경모세포종에서 $^{18}F-FDG$ PET의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET in Neuroblastoma)

  • 팽진철
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.134-136
    • /
    • 2008
  • Neuroblastoma is the most common extracranial solid tumor in children. In diagnostic assessment of neuroblastoma, $^{18}F-FDG$ PET has been reported to have high diagnostic performance, especially, very high sensitivity in staging, restaging, and assessment of therapeutic efficacy. In comparison with conventional diagnostic imaging modalities including a, bone scan, and MIBG scan, $^{18}F-FDG$ PET showed better diagnostic performance. According to clinical research data hitherto, $^{18}F-FDG$ PET is expected to be an effective diagnostic tool in the management of neuroblastoma.

원발성 과호산구증가 증후군 환자들 중 폐침범을 보이는 환자군의 F-18 FDG PET 소견 (F-18 FDG PET Scan findings in Patients with Pulmonary Involvement in the Hypereosinophilic Syndrome)

  • 이재훈;김태훈;윤미진;허진;김태성;김상진;김형중;배문선;유영훈;이종두
    • 대한핵의학회지
    • /
    • 제39권4호
    • /
    • pp.239-245
    • /
    • 2005
  • 목적 : F-18 FDG PET 검사는 염증성이나 감염성 병변에도 위양성 소견을 보일 수 있으며 이로 인하여 악성종양과의 감별진단을 어렵게 만드는 경우가 있다. 원발성 과호산구증가 증후군 (Hypereosinophilic syndrome)은 폐를 포함한 여러 장기에 호산구의 침윤을 보이는 염증성 질환이다. 본 연구를 통하여 이런 폐침범을 보이는 원발성 과호산구증가 증후군 환자에 있어서 PET소견을 분석하고 비정상적인 높은 섭취를 보이는 경우 폐암과 감별되는 소견을 알아보고자 하였다. 대상 및 방법 : 폐암 검진을 목적으로 시행한 저선량 흉부 CT상 결정 및 간유리 음영, 기강경화 소견을 보인 환자들 중 혈액검사상 말초 호산구 과다증을 보인 환자들을 대상으로 FDG PET 검사를 시행 하였다. 이들 중, 기생충 질환 등의 이차성 말초 과다호산구증가증의 원인을 있는 경우 연구에서 제외되었다. 총 8명 환자들의 흉부 CT는 결절, 간유리 음영, 그리고 기강경화 등의 병변 소견 등으로 구분하였으며 그 병변 위치에 상응하는 FDG PET에서 보이는 병변의 maximal 및 mean SUV에 관하여 대조분석하였다. 8명 모두 1-4주 후 추적검사를 시행하여 혈액검사 및 PET과 흉부 CT에서 관찰되었던 병변의 변화소견을 살펴보았다. 결과: 처음 시행한 FDG PET 검사 상, 8명 중 7명에서 높은 섭취를 보였으며 Peak SUV는 $2.8{\sim}10.6$ (평균: $6.4{\pm}2.6$), mean SUV는 $2.2{\sim}7.2$ (평균: $4.1{\pm}1.6$)로 측정되었다. 나머지 1명에서 peak SUV는 1.3, 그리고, mean SUV는 0.7로 측정되었다. 환자들은 평균 15.8일(범위: 7일$\sim$30일) 후 추적검사로 $^{18}F$-FDG PET, 흉부 CT, 그리고, 혈액검사를 시행받았다. PET추적검사 상 이전에 높은 섭취를 보였던 7명 중 6명에서 peak 및 mean SUV의 감소를 보였고 이전에 높은 섭취를 보인 나머지 1명과 낮은 섭취를 보인 1명에서는 병변이 완전히 소실되었다. 이러한 변화 소견은 흉부 CT 추적검사 소견과도 일치하였다. 결론: 원발성 과호산구증가 증후군 환자군에서 폐침범을 보이는 경우, 폐병변은 FDG PET 영상에서 폐암과 유사한정도의 높은 섭취를 보이는 위양성 결과를 나타내어 한번의 PET검사만으로는 양성과 악성을 감별할 수 없었다. 이러한 경우, 추적검사로 CT 및 $^{18}F$-FDG PET를 시행하여 병변의 위치 및 범위, SUV의 변화 소견을 같이 보는 것이 원발성 과호산구증가 증후군 환자에 있어서 보일 수 있는 폐침범 소견과 악성 종양을 감별하는 데 도움을 줄 수 있을 것으로 생각된다.

I-131 MIBG와 F-18 FDG 섭취의 불일치를 보였던 악성 부신경절종 1례 (A Significant Discrepancy of Uptake between I-131 MIBG and F-18 FDG in a Patient With Malignant Paraganglioma)

  • 김종수;김현근;최규영;박형기;김은실;김윤권;김소연;김영중;이효진
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.247-251
    • /
    • 2007
  • A 38-year-old man who was diagnosed with malignant paraganglioma underwent computed tomography (CT) and I-131 metaiodobenzylguanidine (MIBG) san. CT showed extensive lymph node enlargement in right iliac area and retroperitoneum with severe hydronephrosis and mass on posterior bladder wall. However, I-131 MIBG scan didn't showed abnormal uptake. He also underwent F-18 fluorodeoxyglucose (FDG) positron emisson tomography/CT for localizing accurate tumor site. F-18 FDG PET/CT showed multiple metastases of left supraclavicular, hilar, mediastinal para-aortic, inguinal, right iliac lymph nodes, lung, vertebrae, and pelvis. There are a few reports showing that the F-18 FDG PET/CT is helpful for staging and localizing tumor site of patients who are diagnosed with negative on the MIBG scans. Thus, we report a case with paraganglioma which showed negative I-131 MIBG scan, but revealed multiple intense hypermetabolic foci in F-18 FDG PET/CT.

신세포암에서 $^{18}F-FDG-PET/CT$ ($^{18}F-FDG-PET/CT$ in Renal Cell Carcinoma)

  • 전태주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.126-129
    • /
    • 2008
  • Renal cell carcinoma is the most common histological type of renal malignancy, predominant in men and the primary treatment modality of this tumor is surgery. The role of diagnostic imaging in the management of this tumor is the evaluation of extent of disease as well as the detection and characterization of renal mass. US has long been a routine screening tool for kidney but tomographic imaging modalities such as CT and MRI begin to be also commonly used these days. On the other hand, the sensitivity of $^{18}F-FDG-PET$ in detection of renal mass is relatively low because of inherent limitation caused by FDG excretion pathway despite avid uptake of FDG to tumor cell per se. Many studies revealed FDG PET scan could play an important role in detection of metastatic lesions although the sensitivity for the detection of primary lesion is not so high. Furthermore, development of PET/CT scanner will make it possible to expand the indication of FDG PET scan in this malignancy.

회귀방법에 의한 초음파 진단기의 측면해상도 개선에 관한 연구 (A recursive scheme for improvement of the lateral resolution in B-scan ultrasonography)

  • 김선일;민병구;고명삼
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.204-208
    • /
    • 1982
  • The objective of this paper is to present a digital method for improving the lateral resolution of the B-scan images in the medical applications of ultrasound. The method is based upon a mathematical model of the lateral blurring caused by the finite beam width of the transducers. This model provides a simple method of applying a recursive scheme for image restoration with fast computation time. The point spread function (P.S.F.) can be measured by the reflective signals after scanning the small pins located along the depth of interest. From the measured P.S.F., one can compute the coefficient matrices of the inverse discrete-time dynamic state variable equation of the blurring process. Then, a recursive scheme for deblurring is applied to the recorded B-scan to improve the lateral resolution. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

In Orbit Radiometric Calibration Tests of COMS MI Infrared Channels

  • Jin, Kyoung-Wook;Seo, Seok-Bae
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.369-377
    • /
    • 2011
  • Since well-calibrated satellite data is critical for their applications, calibration and validation of COMS science data was one of the key activities during the IOT. COMS MI radiometric calibration process was divided into two phases according to the out-gassing of the sensor: calibrations of the visible (VI) and infrared (IR) channels. Different from the VIS calibration, the calibration steps for the IR channels followed additional processes to secure their radiometric performances. Primary calibration steps of the IR were scan mirror emissivity correction, midnight effect compensation, slope averaging and 1/f noise compensation after a nominal calibration. First, the scan mirror emissivity correction was conducted to compensate the variability of the scan mirror emissivity driven by the coating material on the scan mirror. Second, the midnight effect correction was performed to remove unreasonable high spikes of the slope values caused by the excessive radiative sources during the local midnight. After these steps, the residual (difference between the previous slope and the given slope) was filtered by a smoothing routine to eliminate the remnant random noises. The 1/f noise compensation was also carried out to filter out the lower frequency noises caused from the electronics in the Imager. With through calibration processes during the entire IOT period, the calibrated IR data showed excellent performances.

PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가 (The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT)

  • 김진영;이승재;정석;박민수;강천구;임한상;김재삼
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.63-67
    • /
    • 2015
  • 환자의 호흡에 의해 발생되는 인공물의 감소를 위한 다양한 방법들 중 호흡동조 시스템(이하 Q static scan)과 비교하여 CTAC Shift 보정방법, Additional scan(추가 검사방법)을 평가해보고자 한다. 본 연구는 2015년 2월에서 5월까지 본원을 내원한 환자들 중 영상에서 호흡에 의해 인공물이 발생한 환자 10명을 대상으로 진행하였으며 장비는 PET-CT Discovery 710 (GE Healthcare, MI, USA)과 호흡동조 시스템인 Varian사의 RPM system을 사용하였다. 환자는 24시간동안의 운동금지, 12시간동안 커피와 담배 금지, 8시간동안 금식을 한 후 충분한 수분을 섭취하고 도착시 혈관확보를 한 후 혈당 체크를 진행하며 $^{18}F$-FDG를 kg당 5.18 Mbq을 주사하였다. 그 후 1시간동안 안정을 취하고, 배뇨 후 검사를 진행하였다. CT조건은 관전압 120 kVp와 관전류 60 mAs, DFOV는 70 cm, Matrix size는 $192{\times}192$으로 모두 동일하게 진행하였다. 인공물이 발생한 영상을 기준으로 Additional scan, 호흡동조 시스템을 연동한 Q static scan, CTAC Shift 보정방법을 통해 영상화하였다. 각각의 영상에서 인공물의 감소를 비교하였으며, 육안적 평가와 SUVmax의 변화를 측정하였다. 인공물이 발생한 Whole body scan(WBS)을 통해 얻은 영상 대비 CTAC Shift 보정방법을 통해 얻은 영상의 경우 12~56%, Q static scan 영상은 17~54%, Additional scan 영상은 -27~46%의 변화율을 보였다. Blind Test에서는 CTAC Shift 보정영상이 4점으로 가장 높은 점수를 얻었고 Q static scan 영상이 3.5점, Additional scan 영상이 3.4점의 점수를 얻었다. Oneway ANOVA 검정을 통해 기준이 된 WBS scan 영상과 세 가지 Scan방법간에 유의한 차이를 보였으며(p<0.05) 세 가지 Scan방법간에는 유의한 차이를 보이지 않았다(p>0.05). 그러나 Blind test에서는 세 가지 Scan방법간의 유의한 차이를 보였다. Additional scan과 Q static scan은 CTAC Shift 보정 방법보다 시간이 소요되며 환자에게 CT 재촬영에 의한 과피폭이 우려되며 Q static scan은 호흡의 기복이 심하거나 통증으로 인해 호흡 주기가 불규칙한 환자의 경우 적용하기에 어려움이 있다. CTAC Shift 보정 방법의 경우 제한적으로 보정이 가능하며 그 범위 또한 제한적이다. 이를 보완하기 위해 각 병원의 시스템을 적절히 이용하고 각 방법의 장점의 여러 요소들을 발전시킨다면 진단적 가치를 높이기 위한 방법의 하나로써 유용할 것으로 사료된다.

  • PDF