• 제목/요약/키워드: F-SCAN

검색결과 341건 처리시간 0.02초

전립선암에서 골전이 진단에 대한 F-18 FDG PET/CT와 골스캔의 불일치 (Discrepancy of Bone Metastases between F-18 FDG PET/CT and Bone Scan in a Patient with Prostate Cancer)

  • 최승진;김철수;변성수;현인영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권5호
    • /
    • pp.275-278
    • /
    • 2006
  • We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

발 압력 측정계(F-mat과 F-scan system)의 신뢰성과 타당성에 대한 연구 (Intermachine Validity and Reliability of The F-mat and F-scan)

  • 김경;박영한;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.29-37
    • /
    • 2000
  • 본 연구의 목적은 힘판(Force plate)의 지면반발력(Ground reaction force)의 비교에 따라 발압력 측정계(F-메트와 F-스킨)의 상호 기계간의 신뢰성과 타당성을 연구하는 데에 목적을 두고 있으며 정상인과 리스프랑크(Lisfranc) 골절을 가지고 있는 환자를 대상으로 분석 연구하게 되었다. 힘판의 지면 반발력을 기준치로 설정하고 정상인과 환자의 각각 오른발과 왼발의 스텝에 대해 F 메트(F-mat) 와 F 스캔(F-scan) 시스템의 그래픽 비교 모식과 시간에따른 보령분석의 차이에 따라 이 논문에 대한 결과를 얻을 수 있었다. 본 연구에서는 F 스킨 시스템의 데이터 분석기인 새로운 버전 3.622와 마이크로 소프트웨어인 엑셀 97을 통해 새 시스템의 힘의 평균치와 그래픽을 통해 비교 분석하게 되었으며 다음과 같은 세가지 결론을 얻을 수 있었다. 첫 번째로 F스캔의 지면 반발력은 힘판과 비교되어질 때 통계학적으로 중요한 차이점을 얻을 수 없을 것이다. 두 번째, F 메트를 위한 지면 반발력 역시 힘판과 비교되어질 때 통계학적으로 중요한 차이점율 얻음 수 없을 것이다. 세 번째로 정상군과 실험군의 지면 반발력에 대해 중요한 차이점이 있을 것이라는 것이 밝혀졌다. 특히 정상군의 대상자는 실험군의 대상자와 비교되어질 때 각 발에 대해 증가된 지면 반발력을 나타내었다. 이상 본 연구에 대해 다음의 결론을 내릴 수가 있었고 기존의 F 스캔 시스템이 임상적으로 많이 쓰여졌지만 F 스캔의 센서에 대해 많은 이견 차이를 보였었다. 한편. F메트 시스템에서 F메트 센서의 일관성에 대해서는 어느 연구 논문도 나오지 않았고 이에 대해 F스캔(F-scan)과 힘판(Force plate)를 상호 비교하여 F메트 시스템에 대한 신뢰성과 타당성을 연구하는데 목적을 두게되었다.

  • PDF

갑상선암에서 PET의 역할 (The Role of PET in Thyroid Cancer)

  • 여정석
    • 대한핵의학회지
    • /
    • 제36권3호
    • /
    • pp.147-154
    • /
    • 2002
  • The role of PET in the diagnosis and management of thyroid cancer is discussed. The major role of F-18 FDG PET is on patients with discordant negative I-131 scan and a positive serum thyroglobulin values. F-18 FDG PET scan localized metastatic sites in I-131 scan-negative thyroid carcinoma patients with high accuracy. F-18 PET is also valuable in medullary thyroid cancer with high calcitonin level. Focal thyroid uptake in patients with non-thyroidal diseas has high likelihood of thyroid cancer.

전립선암에서 $^{18}F-FDG-PET/CT$ ($^{18}F-FDG-PET/CT$ in Prostate Cancer)

  • 전태주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.116-120
    • /
    • 2008
  • Prostate cancer is the second leading cause of cancer death of men in western countries and the death related to this disease in Korea is also getting increased. Although anatomic imaging tools such as transrectal US or MRI have been playing a great role in detection of primary prostate lesion, the evaluation of regional lymph node or distant organ metastasis using these modalities is not successful. $^{18}F-FDG-PET$ scan is emerging diagnostic tool for various malignancies. Considering the usual characteristics of prostate cancer such as slow growing and osteoblastic metastasis, the application of FDG PET scan to this disease might be limited. However, in advanced prostate cancer refractory to chemotherapy, FDG PET scan show strong FDG uptake and SUV changes in serial PET scan can be a good indicator of treatment response. Although FDG PET can be useful only in limited cases of prostate cancer, its indication can be widened in future owing to rapid technical improvement and accumulated experiences in this field.

18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구 (Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day)

  • 함준철;박민수;반영각;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.68-72
    • /
    • 2014
  • 핵의학 검사는 반감기로 인한 동위원소의 잔류로 당일에 두 가지 검사를 시행하는데 어려움이 있다. 본 연구는 $^{18}F$-FDG와 $^{99m}TcO_4{^-}$의 상호 영향을 연구함으로써 당일 검사를 진행할 경우 고려될 사항에 대해 알아보고자 한다. NEMA-1994 Phantom을 이용하여 세 번의 실험을 진행했다. 첫 실험은 $^{99m}TcO_4{^-}$을 HOT과 BKG 비 4:1로 만들어 GE사의 INFINIA 장비로 SPECT를 시행하였고, BKG 영역에 $^{18}F$-FDG 37 MBq을 주입 후 동일 조건으로 60분에 1회씩 13회 Scan 했다. 두 번째는 $^{18}F$-FDG를 HOT과 BKG 비 4:1 로 만들어 GE사의 PET/CT Discovery 600 에서 Scan 하였고, BKG 영역에 $^{99m}TcO_4{^-}$을 148 MBq 주입 후 동일 조건으로 60분에 1회씩 6회 Scan 했다. 마지막 실험은 $^{18}F$-FDG를 HOT과 BKG 비 4 : 1로 만들고 1 Bed Scan 후 $^{99m}TcO_4{^-}$을 148 MBq 및 296 MBq씩 증가 시키며 같은 조건으로 1 Bed Scan했다. HOT과 BKG 영역의 비, CNR 혹은 SNR 그리고 총 획득 계수를 측정 후 비교 했다. $^{18}F$-FDG는 SPECT 시행 시 비율 및 CNR에 유의한 차이를 보였다(p>0.05). $^{99m}TcO_4{^-}$는 PET/CT 시행 시 비율 및 SNR이 유의한 차이를 보이지 않았다(p<0.05). $^{99m}TcO_4{^-}$이 PET/CT 검사의 Total Counts를 감소시킨다는 결과를 획득했다. PET/CT 검사를 한 경우 12시간 까지도 $^{99m}TcO_4{^-}$을 이용한 검사에 영향을 미칠 수 있으며, $^{99m}TcO_4{^-}$를 먼저 시행한 경우에는 PET/CT 검사에 SUV 및 SNR에 영향은 없지만 검출 효율을 감소시켰다. 당일 검사 시에는 $^{99m}TcO_4{^-}$을 이용한 검사를 먼저 진행하고 PET/CT의 검사 시간을 늘려 검출 효율을 보완하는 방법을 권장하고자 한다.

  • PDF

팬텀 영상을 이용한 PET 스캔시간의 최적화 연구 (Optimization of PET Scan Time Using Phantom Studies)

  • 정하규;김동현;정해조;손혜경;홍순일;윤미진;이종두;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.139-148
    • /
    • 2002
  • The measured attenuation correction with transmission (Tx) scans produced quantitatively accurate images. However, it was not clear for optimal emission (Ex) and Tx scan time in PET imaging. This study was to evaluate acceptable Ex and Tx scan time by simulating clinical situations using various phantoms. Cylindrical and NEMA phantom were used for $^{18}$ F-PET scan using 2D protocol in GE Advance PETTM scanner. Cylindrical phantom was filled with 136 MBq 18F, and five regions of interests (ROI) were drawn on 23 slices. NEMA phantom had three inserts containing water, air and polytetrafluoro-ethylene (PTFE). Outside of these inserts were filled with 309 MBq of $^{18}$ F, and total 12 ROIs were drawn on 23 slices. Scans were carried out according to five Ex scan times: 2, 5, 10, 15, and 30 min, and nine Tx scan times: 2, 3, 4, 5, 7, 10, 15, 20, and 30 min. Images were reconstructed using measured attenuation correction, and ROI analyses were performed for all images, and mean, standard deviation (SD), coefficient of variation and percent errors were calculated. For cylindrical phantom study, ROI mean and SD were decreased as Ex and Tx time increased. Coefficients of variation were kept constant, when Tx was greater than 10 min. The amount of error decreased for the increment of Ex time from 10 min to 15 min was almost the same to that from 15 min to 30 min. In NEMA phantom Tx 15 min showed the lowest er개r level when the percent errors for three inserts were summed for all of the Ex times. This study suggested that Ex 15 min and Tx 15 min were acceptable as optimal scan time for the scanning protocol and the dose of radiopharmaceuticals used in these phantom study.

  • PDF

단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가 (The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide)

  • 홍건철;차은선;곽인석;이혁;박훈;최춘기;석재동
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.102-107
    • /
    • 2012
  • 단 반감기 핵종을 이용한 PET검사는 방사성동위원소의 빠른 물리적 붕괴로 인하여 영상 획득을 위한 계수검출이 제한적이다. 이러한 이유로 비교적 낮은 감도의 검사에서는 보다 정확한 정량적 평가를 위하여 긴 시간동안 영상 획득을 적용하기도 한다. 본 연구에서는 $^{11}C$$^{18}F$를 이용한 PET 검사 시 영상 획득 시간에 따른 차이를 평가하여 합리적인 영상 획득 시간에 관하여 알아보고자 한다. 1994 NEMA Phantom에 $^{11}C$$30.08{\pm}4.22MBq$, $^{18}F$$40.08{\pm}8.29MBq$을 증류수에 희석하여 채운 후 $^{11}C$은 동적영상 1분씩 20회, 정적 영상 20분, $^{18}F$은 동적영상 2분30초씩 20회, 정적영상 50분을 획득하였다. 모든 데이터는 동일한 재구성법을 적용하였으며, 시간의 경과에 따른 붕괴보정을 적용하였다. 방출영상에 관심영역을 설정하고 최대 방사능 농도값(kBq/mL)을 비교하였으며, 각각의 동적영상을 영상 획득 시간의 증가에 따라 1개씩 증가시켜 영상 합산(Image summation) 후 영상의 관심 영역 내에서의 최대 방사능 농도값(kBq/mL)을 평가하였다. $^{11}C$ 동적영상의 시간 경과에 따른 최대 방사능 농도값은 $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$, 정적영상은 $2.15{\pm}0.26kBq/mL$였다. $^{18}F$ 동적영상은 $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$, 정적영상은 $7.24{\pm}0.14kBq/mL$였다. $^{11}C$의 동적영상 합산에서 영상 획득 시간의 합이 5, 10, 15, 20분으로 증가할수록 $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$으로 감소하였으며, $^{18}F$의 경우 합산된 영상 획득 시간의 합이 12분 30초, 25분, 37분 30초, 50분으로 증가할수록 $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$으로 감소하였다. 영상의 질을 평가 하는 SNR에서는 $^{11}C$$^{18}F$ 모두 동적영상획득 방법에서는 주사 후 시간이 흐를수록 SNR가 저하 되었으나, 영상 합산획득 방법에서는 합산 횟수가 증가 할수록 SNR가 향상 되는 것을 알 수 있었다. 동적영상에서 시간 경과에 따른 최대 방사능 농도값은 $^{11}C$$^{18}F$에서 증가하였고, 동적영상 합산의 경우는 합산수가 증가함에 따라 최대 방사능 농도값은 $^{11}C$$^{18}F$ 감소함을 보였다. $^{18}F$을 이용할 경우에는 시간 경과에 따른 정량평가의 오차를 크게 고려하지 않아도 될 것으로 사료되고, $^{11}C$를 이용한 PET 검사는 시간경과에 따른 감쇠 보정의 오차를 감안하여 추가의 감쇠 보정법을 적용하거나 30%정도의 오차를 적용하여 정적영상 획득시간을 반감기의 25% 이내인 5분 내외로 설정해야 할 것이다.

  • PDF

좌측 대퇴골에 발생한 만성골수염의 PET와 MDP scan 영상 (FDG-PET and MDP scan findings in chronic osteomyelitis of the left femur)

  • 박찬희;이명훈
    • 대한핵의학회지
    • /
    • 제36권2호
    • /
    • pp.143-145
    • /
    • 2002
  • A 49-year-old male patient with a carcinoma of the right pyriform sinus had a whole-body bone scan and gamma camera based F-18 FDG-PET for staging. Tc-99m MDP bone scan depicted diffuse increased uptake in the left femur due to chronic osteomyelitis but no skeletal metastasis. F-18-FDG-PET revealed increased focal bone uptake and uptake in the draining sinus due to chronic osteomyelitis in addition to visualization of the right pyriform sinus carcinoma and right neck nodal uptake. Fluorine-18 fluorodeoxyglucose-positron emission tomography is significantly more accurate than the bone scan in pinpointing chronic osteomyelitis focus and draining soft tissue infection.

$^{18}$F-Fluoride-PET을 이용한 골격계 영상 ($^{18}$F-Fluoride-PET in Skeletal Imaging)

  • 전태주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권4호
    • /
    • pp.253-258
    • /
    • 2009
  • Bone scintigraphy using $^{99m}$Tc-labeled phosphate agents has long been the standard evaluation method for whole skeletal system. However, recent shortage of $^{99m}$Tc supply and advanced positron emission tomography (PET) technology evoked the attention to surrogate radiopharmaceuticals and imaging modalities for bone. Actually, fluorine-18 ($^{18}$F) was the first bone seeking radiotracer before the introduction of $^{99m}$Tc-labeled agents even though its clinical application failed to become pervasive anymore after the rapid spread of Anger type gamma camera systems in early 1970s. However, rapidly developed PET technology made us refocus on the usefulness of $^{18}$F as a PET tracer. Early study comparing $^{18}$F-Na PET scan and planar bone scintigraphy reported that PET has higher sensitivity and specificity in the diagnosis of metastatic bone lesions than planar bone scan. Subsequent reports comparing between PET and both planar and SPECT bone image also revealed better results of PET scan in similar study groups. Rapid clinical application of PET/CT also accumulated considerable amount of experiences in skeletal evaluation and this modality is known to have better diagnostic power than stand alone PET system as well as bone scan. Furthermore $^{18}$F-Na PET/CT revealed better or at least equal results in detection of primary and metastatic bone lesions compared with CT and MRI. Therefore, it is obvious that $^{18}$F-Na PET/CT has potential to become new imaging modality for practical skeletal evaluation so continuous and careful evaluation of this modality and radiopharmaceutical must be required.