• Title/Summary/Keyword: F/C ratio

Search Result 1,066, Processing Time 0.029 seconds

Research on Liquefaction Characteristics of SF6 Substitute Gases

  • Yuan, Zhikang;Tu, Youping;Wang, Cong;Qin, Sichen;Chen, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2545-2552
    • /
    • 2018
  • $SF_6$ has been widely used in high voltage power equipment, such as gas insulated switchgear (GIS) and gas insulated transmission line (GIL), because of its excellent insulation and arc extinguishing performance. However, $SF_6$ faces two environmental problems: greenhouse effect and high liquefaction temperature. Therefore, to find the $SF_6$ substitute gases has become a research hotspot in recent years. In this paper, the liquefaction characteristics of $SF_6$ substitute gases were studied. Peng-Robinson equation of state with the van der Waals mixing rule (PR-vdW model) was used to calculate the dew point temperature of the binary gas mixtures, with $SF_6$, $C_3F_8$, $c-C_4F_8$, $CF_3I$ or $C_4F_7N$ as the insulating gas and $N_2$ or $CO_2$ as the buffer gas. The sequence of the dew point temperatures of the binary gas mixtures under the same pressure and composition ratio was obtained. $SF_6/N_2$ < $SF_6/CO_2$ < $C_3F_8/N_2$ < $C_3F_8/CO_2$ < $CF_3I/N_2$ < $CF_3I/CO_2$ < $c-C_4F_8/N_2$ < $C_4F_7N/N_2$ < $c-C_4F_8/CO_2$ < $C_4F_7N/CO_2$. $SF_6/N_2$ gas mixture showed the best temperature adaptability and $C_4F_7N/CO_2$ gas mixture showed the worst temperature adaptability. Furthermore, the dew point temperatures of the $SF_6$ substitute gases at different pressures and the upper limits of the insulating gas mole fraction at $-30^{\circ}C$, $-20^{\circ}C$ and $-10^{\circ}C$ were obtained. The results would supply sufficient data support for GIS/GIL operators and researchers.

Mechanical properties of SFRHSC with metakaolin and ground pumice: Experimental and predictive study

  • Saridemir, Mustafa;Severcan, Metin Hakan;Celikten, Serhat
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.543-555
    • /
    • 2017
  • The mechanical properties of steel fiber reinforced high strength concrete (SFRHSC) made with binary and ternary blends of metakaolin (MK) and ground pumice (GP) are investigated in this study. The investigated properties are ultrasonic pulse velocity ($U_{pv}$), compressive strength ($f_c$), flexural strength ($f_f$) and splitting tensile strength ($f_{st}$) of SFRHSC. A total of 16 steel fiber reinforced concrete mixtures were produced by a total binder content of $500kg/m^3$ for determining the effects of MK and GP on the mechanical properties. The design $f_c$ was acquired from 70 to 100 MPa by using a low water-binder ratio of 0.2. The test results exhibit that high strength concrete can be obtained by replacing the cement with MK and GP. Besides, correlations between these results are executed for comprehending the relationship between mechanical properties of SFRHSC and the strong correlations are observed between these properties. Moreover, two models in the gene expression programming (GEP) for predicting the $f_c$ of SFRHSC made with binary and ternary blends of MK and GP have been developed. The results obtained from these models are compared with the experimental results. These comparisons proved that the results of equations obtained from these models seem to agree with the experimental results.

Efficiency factor of high calcium Class F fly ash in concrete

  • Sata, V.;Khammathit, P.;Chindaprasirt, P.
    • Computers and Concrete
    • /
    • v.8 no.5
    • /
    • pp.583-595
    • /
    • 2011
  • This paper studied the cement efficiency factor (k factor) of high calcium Class F fly ash. This k factor represents a unit of fly ash with efficiency equivalent to k unit of cement. The high calcium Class F fly ash was used to replace cement in concrete. The modified Bolomey's law with linear relationship was used for the analysis of the result of compressive strength, cement to water ratio (c/w) and fly ash to water ratio (f/w) by using the multi-linear regression to determine the k factor and other constants in the equations. The results of analysis were compared with the results from other researcher and showed that the k factor of high calcium Class F fly ash depends on the fineness of fly ash, replacement level and curing age. While the amount of CaO content in Class F fly ash not evident. Furthermore, necessary criteria and variables for the determination of the k factor including the use of the k factor in concrete mix design containing fly ash were proposed.

Analysis of Flow Characteristics of the Improved-Pneumatic-Movable Weir through the Laboratory Experiments (실내실험을 통한 개량형 공압식 가동보의 월류흐름 특성 분석)

  • Lee, Kyung Su;Jang, Chang-Lae;Lee, Namjoo;Ahn, Sang Jin
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.11
    • /
    • pp.1007-1015
    • /
    • 2014
  • This study investigates the discharge coefficient of Improved-Pneumatic-Movable (IPM) weir through the weir, a kind of movable weirs, to estimate much more accurate rating curves using laboratory flume experiments. The discharge coefficient ($C_d$) is from 0.613 to 0.634 by the stand-up angle of the weir. The upstream Froude Number ($F_{r1}$), relative crest length(${\xi}$), Headwater Ratio ($H_1/W$), the Overflow depth ratio of weir crest ($y_c/y_1$) was changed by the upstream. And the downstream Froude number ($F_{r2}$), the Overflow depth ratio of weir crest and Downstream Water depth ($y_c/y_2$) was changed by the downstream. The ratio of Downstream and Up and Downstream water Depth (${\Delta}y/y_2$) was found to be changed by both of the up and downstream flow. They considered the major influence variables and derived the Discharge coefficient Formula at this study. The Discharge coefficient of the Improved-Pneumatic-Movable (IPM) weir was settled by the height of the Movable weir, that is to say, it was settled by the flow conditions of upstream approach flow head and physical data according to the standing angle.

Bedding Fabric Performance Using Polyester, Tencel and Cotton MVS Blended Spun Yarns (PET, Tencel, Cotton MVS 혼방사로 제직된 침구용 직물의 성능평가)

  • Sa, A-Na;Lee, Jung Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • This study evaluated the performance of bedding fabrics consisting of warp (150d/144f, polyester) and weft (polyester, Tencel and cotton MVS blended spun yarn) with blend ratio of weft. We measured electrostatic propensity, moisture properties, pilling properties and mechanical properties of the fabrics for this study. F-P fabric showed outstanding moisture properties and pilling properties. However, tensile properties and electrostatic propensity were relatively inferior to other characteristic values. Significant static electricity may make F-P fabric uncomfortable. F-P7C3 fabric showed outstanding moisture properties and pilling properties. Static electricity may make F-P7C3 fabric uncomfortable; in addition, F-P5C5 fabric showed outstanding moisture properties and pilling properties. Rough and stiff hand feel were expected to increase because tensile properties decreased and surface properties increased. F-C fabric showed outstanding pilling properties and electrostatic propensity. However, it showed inferior moisture control properties. F-P5T4C1 fabric showed outstanding moisture properties, pilling properties and electrostatic propensity. Several properties are outstanding; however, the hand feels are very rough and stiff from bending. The water evaporation and static electricity increased with increasing polyester content. As the content of cotton increased, tensile properties were improved. However, water evaporation and static electricity decreased. The addition of Tencel increased the thickness and compression energy so that it exhibited a soft characteristic upon compression and an excellent moisture control properties, but the surface became somewhat coarse.

Shear Strength of Intermediate Soils with Different Types of Fines and Sands

  • Kim, Ukgie;Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.33-42
    • /
    • 2013
  • In this paper, a series of monotonic undrained shear tests were carried out on four kinds of sand-fine mixtures with various fines content. Two kinds of sands (Silica sand V3, V6) and fines (Iwakuni natural clay, Tottori silt) were mixed together in various proportions, while paying attention to the void ratio expressed in terms of sand structure $(F_c{\leq}F_{cth})$. The undrained shear strength of mixtures below the threshold fines content was observed so that as the plastic fines content increases, maximum deviator stress ratio decrease for dense samples while an increase is noted for loose samples. For non-plastic fines, the increase in the amount of fines leads to an increase in density of the soil, which results in an increase in strength. Then, the monotonic shear strength of the mixtures was estimated using the concept of granular void ratio. It was found that the shear strength of mixtures is greatly dependent on the skeleton structure of sand particles.

Dentinal Tubules Occluding Effect Using Nonthermal Atmospheric Plasma

  • Lee, Chang Han;Kim, Young Min;Kim, Gyoo Cheon;Kim, Shin
    • International Journal of Oral Biology
    • /
    • v.43 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • Nonthermal atmospheric plasma has been studied for its many biomedical effects, such as tooth bleaching, wound healing, and coagulation. In this study, the effects of dentinal tubules occlusion were investigated using fluoride-carboxymethyl cellulose (F-CMC) gel, nano-sized hydroxyapatite (n-HA), and nonthermal atmospheric plasma. Human dentin specimens were divided to 5 groups (group C, HA, HAF, HAP, and HAFP). Group HA was treated with n-HA, group HAF was treated with n-HA after a F-CMC gel application, group HAP was treated with n-HA after a plasma treatment and group HAFP was treated with n-HA after a plasma and F-CMC gel treatment. The occlusion of dentinal tubules was investigated using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), which shows Ca/P ratio. In the EDS results, a higher Ca/P ratio was shown in the groups including n-HA than in the control group. The specimens of group HAP and HAFP had a higher Ca/P ratio in retentivity. In the SEM results, there was not a significant difference in the amount of times applied. Therefore, this study suggests F-CMC gel and n-HA treatment using nonthermal atmospheric plasma will be a new treatment method for decreasing hypersensitivity.

Synthesis of SiC Whiskers from Rice Hulls (생왕겨를 이용한 실리콘 카바이드 합성)

  • 길경선;김종학;고인용
    • Resources Recycling
    • /
    • v.2 no.4
    • /
    • pp.17-22
    • /
    • 1993
  • SiC whiskers were synthesized from rice hulls and activated carbon by carbothermal reduction method. The effects of gases and various additives were studied. Carbothermal reduction to produce SiC whiskers was conducted at $1450^{\circ}C$ and the synthesized SiC whiskers were examined using SEM and XRD. The length of whiskers is increased with the increases of $H_2$concentration and total gas flows. The most favorable form of SiC whiskers couble be obtained in the following experimental conditins : Ar : $H_2$=300:45(ml/min), $SiO_2$(inrice hulls): $CaF_2$=1:0.5:0.5(mole ratio) and the addition of Ni flakes ($1{\times}1$mm).

  • PDF

Suitable Dietary Protein/Lipid Ratio for Hybrid, Female Red Sea Bream Pagrus major and Male Black Sea Bream Acanthopagrus schlegeli in the Juvenile Stage, Compared with Red Sea Bream

  • Kim, Yang-Su;Ji, Seung-Cheol;Biswas, Amal;Biswas, Biswajit Kumar;Yong, Annita Seok Kian;Takaoka, Osamu;Jeong, Gwan-Sik;Murata, Osamu;Takii, Kenji
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.75-84
    • /
    • 2014
  • To determine a suitable dietary protein/lipid (CP/CL) ratio in the early juvenile stages of hybrid porgy ($F_1$), female red sea bream (RSB) ${\times}$ male black sea bream, five diets with various CP/CL ratios-60/7, 55/12, 51/17, 46/23, and 41/28-were prepared and provided to juveniles in triplicate. At the smaller juvenile stage, $F_1$, weighing 0.32 g, a significantly higher specific growth rate (SGR) and feed efficiency (FE) were seen with 60/7 and 55/12 diets. However, in RSB weighing 0.26 g, SGR and FE were higher with the 60/7 diet than the other diets at $21^{\circ}C$. At the larger juvenile stage, $F_1$, weighing 3.7 g, there was no significant difference in SGR or FE among the diets, but RSB weighing 4.0 g fed 60/7, 55/12, and 51/17 diets had higher SGR and FE than 46/23 and 41/28 diets at $24^{\circ}C$. Moreover, survival and apparent nutrient retention of $F_1$ at both stages were significantly higher than those in RSB. These results indicate that both $F_1$ and RSB weighing ca. 0.3 g require a higher dietary CP/CL than those weighing ca. 4 g. Additionally, $F_1$ in both trials showed the suitability of a lower dietary CP/CL than RSB, indicating that mass production of $F_1$ juveniles will be more economical than RSB.

Design of the Detection Circuitry for the Characteristics of Micromachined Vibrating Gyroscope (미세가공 진동형 자이로스코프의 특성 감지 회로의 설계에 관한 연구)

  • U, Yeong-Sin;Byeon, Gwang-Gyun;Seo, Il-Won;Seong, Man-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.687-692
    • /
    • 1999
  • A new technique to measure low level capacitance variations of the gyroscope is proposed and verified by computer simulation. It is based on the new CV(capacitance-voltage) converter circuit biased by dc current source and the peak detector without low pass filter. The CV converter biased by dc current source provides good signal-to-noise ratio and this setup of the detection circuitry without low pass filter makes it possible to provide short settling time, that is, higher speed of measurement and wide operation range if only a few parameters are adjusted. The key parameters that affect the performance of the detection circuitry are illustrated and computer simulation results are presented. The demonstrated detection circuitry shows linear response from 10 fF to 130 fF at 10 kHz and shows good linearity.

  • PDF