• Title/Summary/Keyword: Eyes

Search Result 2,547, Processing Time 0.023 seconds

The Stability Appraisement on Cultural Property Material with the Replacing Fumigation Gas of Methyl Bromide (Methyl Bromide를 대체하는 훈증 가스의 문화재 재질 안정성 평가)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.283-291
    • /
    • 2009
  • Methyl Bromide that was used as fumigation gas turned out to be the substance of destroying the ozone layer. For that reason, at the Montreal Protocol in 1987 the use of methyl bromide was forbidden starting 2005 in the advanced country. Also according to the 2007 Bali Protocolly methyl bromide is expected to be forbidden and therefore the purpose of this study is to find out the effects of substitution fumigation gas (Ethylene Oxide+HFC 134a, Methyl Iodide, Cyanogen and Argon) on the metal(silver, copper and iron), wood(oregon pine), pigment(yellow, red, blue, white and black), textile(hemp, ramie, jute, silk1 and silk2 / indigo, safflower and cork) and paper. After the fumigation test, ethylene oxide+HFC 134a did not have changes in the weight and color of the material itself before and after the experiment. On exterior alteration, color change occurred partly on paper and metal. Also, in most materials color change extent was 0.5 to 1.5 on the average and showed scanty difference. The materials after the fumigation test with methyl iodide did not show weight changes after the test. However, color changes more than 1.0 was shown in most of the materials especially in dyed textile material. In blue pigment, the discoloration on the surface could be seen by naked eyes. Fumigation test with cyanogen gas did not show weight changes and discoloration is more than 1.5 before and after the test. The weight changes of test materials with the argon gas was decreased about 3 to 6%. It can be observed that discoloration on paper was generated. Color changes can be seen on jute dyed with safflower and cork for two weeks with argon gas and the extent was 6.3 and 6.0.

  • PDF

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

The Associated Factors with Xerostomia in Patients with Systemic Diseases (일부 전신질환자에서 구강건조증의 관련요인 분석)

  • Kim, Sun-Ju;Choi, Jun-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.386-392
    • /
    • 2013
  • The purpose of this study was to evaluate the factors related to xerostomia in patients with systemic diseases, and the results were analyzed through t-test, ANOVA, and multiple linear regression analysis. There were 62 respondents (56.9%) who reported dry mouth and the season of the most severe dry mouth was reported to be the highest during winter. According to the analysis made in the relationship of xerostomia with the awareness of general health and health behavior, the group that understood their own health poorly, had more than two kinds of diseases, and had been administered more than two kinds of daily medication showed higher xerostomia. Also, those who experienced desperation, had high dryness in other parts of the body, and heavy snoring were more aware of xerostomia (p<0.05). According to the analysis made in the relationship between xerostomia and awareness of oral health state, the group that understood their oral health poorly and had pain in the oral mucous membrane and halitosis was more aware of xerostomia (p<0.05). According to the analysis made in the relationship between quality of life and xerostomia, the group that showed high level of problem in daily living and stress and were self-conscious and felt tense due to halitosis reported more xerostomia (p<0.05). Finally, xerostomia was most correlated with consciousness of the eyes of others due to halitosis followed by the number of transferred systemic diseases and stress level. Based on such results, xerostomia was understood to be an obstacle in maintaining favorable social life and health. Since xerostomia was shown to be related to the number of transferred systemic diseases, the dental professions are asked to further improve their understanding not only on oral health but also systemic diseases. Therefore, these efforts are expected to prevent xerostomia and reduce various complications caused by xerostomia.

Analysis of Quorum Sensing-Related Phenotypes of Pseudomonas aeruginosa Clinical Isolates (녹농균 임상균주의 쿼럼 센싱 관련 표현형 분석)

  • Jung, Kyung-Ju;Choi, Yu-Sang;Ha, Chang-Wan;Shin, Jeong-Hwan;Lee, Joon-Hee
    • Korean Journal of Microbiology
    • /
    • v.46 no.3
    • /
    • pp.240-247
    • /
    • 2010
  • Pseudomonas aeruginosa is a Gram (-) opportunistic human pathogen causing a wide variety of infections on lung, urinary tract, eyes, and burn wound sites and quorum sensing (QS), a cell density-sensing mechanism plays an essential role in Pseudomonas pathogenesis. In order to investigate the importance of QS in the Pseudomonas infections of Korean patients, we isolated 189 clinical strains of P. aeruginosa from the patients in Pusan Paik Hospital, Busan, South Korea. The QS signal production of these clinical isolates was measured by signal diffusion assay on solid media using reporter strains. While most clinical strains (79.4%) produced the QS signals as similar level as a wild type strain, PAO1 did, where LasR, the initial QS signal sensor-regulator was fully activated, a minority of them (4.2%) produced much less QS signals at the level to which LasR failed to respond. Similarly, while 72.5% of the clinical isolates produced QS signals enough to activate QscR, an another QS signal sensor-regulator, some few of them (9%) produced the QS signals at much lower level where QscR was not activated. For further analysis, we selected 74 clinical strains that were obtained from the patients under suspicion of Pseudomonas infection and investigated the total protease activity that is considered important for virulence. Interestingly, significant portion of them showed very low protease activity (44.6%) or no detectable protease activity (12.2%). When the biofilm-forming ability that is considered very important in chronic infection was examined, most isolates showed lower biofilm-forming activity than PAO1. Similarly, significant portion of clinical isolates showed reduced motility (reduced swarming activity in 51.4% and reduced twitching activity in 41.9%), or non-detectable motility (swarming-negative in 28.4% and twitching-negative in 28.4%). Our result showed that the clinical isolates that produced QS signals at the similar level to wild type could have significantly reduced activities in the protease production, biofilm formation, and motility, and some clinical isolates had unique patterns of motility, biofilm formation, and protease production that are not correlated to their QS activity.

The clinical study of Myasthenia Gravis (중증근무력증(重症筋無力症)에 대(對) 임상적(臨床的) 연구(硏究))

  • Chae, Byung-Yoon
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.190-211
    • /
    • 1996
  • Generally the Myasthenia Gravis is classified into two of hereditary factor and acquement. Aquired Myasthenia Gravis was Quite well known to be caused by the autoimmune mechanism. Not in accurateness, on the hereditary, acetylcholine receptor antibody was to be analyzed very high in their parents and brothers. Also Myasthenia Gravis is a chronic disease characterized by voluntary muscle weakness and fatigue. above all, ocular Myasthenia Gravis is characterized clinically by blepharoptosis and external ophthalmoplegia and to be showed abut 90% cases and so oriental medicine can not but deal with myasthenia gravis at blepharoptosis. Accordinglv 20 out patients with Myasthenia Gravis were clinical study and observation as to the sex, age, progress state of MG, blood type, history, main symptom, liking for warm and cool food and tepidity, state of pulse, treatment of acupuncture and administration of oriental medicine etc. The results were as follows. 1. There was investigaed on the frequency of attack for sex, age, oculus dexter, oculus sinister, oculus uterque. Among the 20 patients, the number of female were 60% with 12 cases and male were 40% with 8 cases, therefore it was the rate of 6 : 4. the patients under 10 ages and 40 ages were 20% with 4 cases, 10 ages and 50 ages were 15% with 3 cases, 20, 30, 60 ages were 10% with 2 cases. And then oculus uterque was 90% with 18 cases, oculus sinister was 10% with 2 cases and oculus dexter were none of them. 2. Stage I were 50% with 10 patients, stage $II_A$ were 30% with 6 patients and stage $II_B$ were 20% with 4 patients, on the clinical stage and too class I were 20% with 4, class II were 45% with 9, class III were 35% with 7, in the functional activity the patients with chest heavy were 15% with 3 and hyperthyroidism were 10% with 2. 3. Hospital which patients had used to before came to this hospital were 10 university hospital and 6 local clinic. 4. The duration of disease was from 3 months to 30 years, the patients suffering between 3 months and within 1 year were 25% with 5 cases, 1-2 years were 30% with 6 cases, therefore within 2 years were 55%. 4-5 years were 15%, over 7 years were appeared less than 10%. 5. In the main symptom, all of patients were appeared to be heavy in opening their eyes the patients with blephroptosis were 70% with 14 cases on the oculus uterque, oculus sinisterf and oculus dexter, there were 20% with 4 eases each other in the oculogyation incomplete. visual failing, ophthalmoxerosis, strabismus etc and indigetion, frequency of urine(feel hurt), mild stools(or diarrea), oversensitiveness etc. but in addition, all of the other were 10%. 6. In the distribution of blood type, 0 types were 45% with 9 cases, A types were 25% with 5 cases, B and AB types were 15% each other. 7. For the rates of patients of liking for warm and cool food or tepidity, patients of liking for warm food possess 45% with 9 cases, and cool food possess 35% with 7 and tepidity possess 20% with 4, and then most of patients liking for warm food were females and cool food were much more males than females. 8. Hyunsae(弦細) were 40% with 8 cases, Buhurl(浮滑) were 20% with 4 cases, Hyunsak(弦數) were 15% with 3 cases, and in addition, the others were 10%, among 7 types of pulses. 9. The patients with less than 1 week were 40% with 8 cases, and there were female most of them and over 4 weeks were 20% and 1-2weeks were 15%, in the duration acupuncture treatment. 10. 15 kinds of prescriptions were administrated with oriental medicine from 1 week to 20weeks 1_2 weeks were 25.71% with 9 cases, 3 weeks were 17.14% with 6 cases and 6 weeks were 11.42% with 4 cases and also Gamibaetaugunbitang(加味培土健脾湯) were 28.57% with 10 cases, Gamijeounyongtang(加味正容湯) were 14.28% with 5 cases, Gamibojoongyigitung (加味補中益氣湯), Gamiyinsamyangyoungtung (加味人蔘養榮湯) were 8.57% with 3 cases each other and also Gamisamgitung (加味蔘?湯), Gamisamuloajatung(加味四物五子湯) Gamigoudungum (加味鉤藤飮), etc were applied.

  • PDF

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

Effect of Visual Sensory Improvement by Amblyopia Treatment on Improvement of Ocular Functions (약시 치료에 의한 시감각 개선이 안기능 향상에 미치는 효과)

  • Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.551-555
    • /
    • 2014
  • Purpose: This study is to investigate if the improvement of visual sensory (VS) by amblyopia treatment affects the ocular functions in refractive errors, accommodative errors and phoria at distance and near. Methods: 10 subjects (17 eyes, mean age of $10.7{\pm}2.9$ years) who treated amblyopia completely, were participated for this study. Refractive errors, accommodative errors, and distance and near phoria were compared between before and after treatments of amblyopia. Refractive errors and accommodative errors at 40 cm were measured using openfield auto-refractor (NVision-5001, Shin Nippon, Japan) and using monocular estimated method (MEM) respectively. Phoria was determined at 3 m for distance and at 40 cm for near using Howell phoria card, cover test or Maddox rod. Results: Mean corrected visual acuity (CVA) significantly increased from $0.46{\pm}0.11$ (decimal notation) for before amblyopia treatment to a level of $1.03{\pm}0.13$ for after amblyopia treatment (p < 0.001). For spherical refractive error, hyperopia significantly decreased from $+2.29{\pm}0.86D$ to a level of $+1.1{\pm}2.38D$ (p < 0.05) but astigmatism did not significantly change; $-1.80{\pm}1.41D$ for before treatment and $-1.65{\pm}1.30D$D for after treatment (p > 0.05). Accommodative error significantly decreased from accommodative lag of $+1.1{\pm}0.75D$ to a level of $+0.5{\pm}0.59D$ (accommodative lag) (p < 0.05). Distance phoria significantly changed from eso $2.9{\pm}6.17PD$ (prism diopters) to a level of eso $0.2{\pm}3.49PD$ (p < 0.05), and near phoria also significantly changed from eso $0.4{\pm}2.32PD$ to level of exo $2{\pm}4.9PD$ (p < 0.05). There was a high correlation (r = 0.88, p < 0.001) between improvement of visual acuity and decrease of accommodative lag. Conclusions: Hyperopic refractive error decreased with improvement of CVA or VS by amblyopia treatment. And the improvement of VS by amblyopia treatment also improved accommodative error, and changed phoria coupled with accommodation.

The Study of Visual Fatigue by Monitor Letter Contrast with an Eye Tracker (아이트래커를 이용한 모니터 글자 대비도에 따른 눈의 피로도 연구)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.533-538
    • /
    • 2014
  • Purpose: This study is to investigate correlation between eye fatigue and letter contrast according to letter contrast changes on monitor display. Methods: Reading speed test were carried out for 53 subjects (mean age: $22.68{\pm}1.85$ years) who have over Best-corrected visual acuity (BCVA) 1.0, and 45 subjects, who could read over 123 out of 163 letters among 53 subjects were selected. They were asked to read the letters which were composed of Black (contrast 100%), Dark gray (contrast 80%), Gray (contrast 80%), Light gray (contrast 30%) randomly. The change of their eye fatigue by letter contrast on monitor display was measured by monitoring their eyes with an eye-tracker while they were reading letters. Results: Event Duration (sec) was 33.635 for Black, 32.266 Dark gray, 33.936 for Gray, and 34.848 for Light gray. Average of Fixation Duration (sec) was 0.224 for Black, 0.218 for Dark gray, 0.239 for Gray and 0.243 for Light gray. Average of Pupil diameter (mm) was 41.133 mm for Black, 41.160 mm for Dark gray, 40.880 mm for Gray and 40.459 mm for Light gray. Frequency (blinks/sec) was 0.211 for Black, 0.206 for Dark gray, 0.221 for Gray, and 0.238 for Light gray. Conclusions: Event Duration and average of Fixation Duration were the shortest for Dark gray and the longest for Light gray. In average Pupil diameter was the biggest Dark gray and the smallest for Light gray. Blink Frequency (blinks/sec) was the lowest for Dark gray and the highest for Light gray. Visual fatigue by brightness of letters on monitor display was the least for Dark gray followed by Black, Gray and Light gray.

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF