• Title/Summary/Keyword: Eyeball

Search Result 178, Processing Time 0.019 seconds

Ultrastructure of the Eye in the Snail, Incilaria fruhstorferi (산민달팽이 (Incilaria fruhstorferi) 눈의 미세구조)

  • Chang, Nam-Sub;Han, Jong-Min;Lee, Kwang-Joo
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.363-377
    • /
    • 1998
  • After the investigation on the eye of Incilaria fruhstorieri with light and electron microscopes, the following results were obtained. The eye of Incilaria fruhstorferi comprises cornea, lens, vitreous body, retina, and optic nerve inward from the outside. Cornea is composed of squamous, cuboid, columnar and irregular cells, which appear to be light due to their low electron density. In their cytoplasms, glycogen granules, multivesicular body, and nucleus were observed. Vitreous body, located behind non-cellular transparent lens, is filled with long and short microvilli protruding from the retinal epithelia. Retinal epithelium, the organ to perceive objects, is divided into four parts; microvillar layer pigment layer, nuclear layer, and neutrophils layer, from the apical portion. Microvillar layer consists of the type-I photoreceptor cells and pigmented granule cells. In the apical portion of their cytoplasms, long microvilli (length, $19{\mu}m$) , short microvilli (length, $8{\mu}m$), and rolled microvilli grow thick in the irregular and mixed forms. Photoreceptor cells are classified into type-I and type-II, according to their structures. The type-I cell has the apical portion rising roundly like a fan and the lower part which looks like the helve of a fan. In the cytoplasm of the apical portion, there are clear vesicles, cored vesicles, ovoid mitochondria, and microfilaments, and in the cytoplasm of the lower part, photic vesicles with their diameters about 60nm aggregate densely. The type-II photoreceptor cell, located at the lower end of the type-I cells, has a very large ovoid nucleus 3nd no microvilli. In the cytoplasm of the type-II cell, the photic vesicles with sizes 60nm aggregate more densely than in the cytoplasm of the type-I cell. Pigmented cells are classified into type-A and type-B, according to their structures. The type-A is identified to be a large cell containing round granules (diameter, $0.5{\mu}m$) of very high electron density, while the type-B is identified as a small cell where the irregular granules (diameter, $0.6{\mu}m$) of a little lower electron density amalgamate. Nuclear layer ranges from the bottom of pigment layer to the top of the capsule, and contains three kinds of nuclei (nuclei of the type-II photoreceptor cell, pigmented granule cell, and accessory neuron). The capsules covering the outmost part of the eyeball are composed of collagenous fiber and three longitudinal muscle layers (the thickness of each longitudinal muscle layer, $0.4{\mu}m$) and thick circular muscle layer (thickness, $0.3{\mu}m$). Around the capsules, there is a neurophile layer consisting of neurons and nerve fibers. Each neuron has a relatively large ovoid nucleus for its cytoplasm, and in the karyosome, large lumps of keterochromatin form a wheel nucleus.

  • PDF

Nerve Injuries after the Operations of Orbital Blow-out Fracture (안와골절 수술 후 발생한 신경손상)

  • Choi, Jae Il;Lee, Seong Pyo;Ji, So Young;Yang, Wan Suk
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2010
  • Purpose: In accordance with the increasing number of accidents caused by various reasons and recently developed fine diagnostic skills, the incidence of orbital blow-out fracture cases is increasing. As it causes complications, such as diplopia and enophthalmos, surgical reduction is commonly required. This article reports a retrospective series of 5 blow-out fracture cases that had unusual nerve injuries after reduction operations. We represents the clinical experiences about treatment process and follow-up. Methods: From January 2000 to August 2009, we treated total 705 blow-out fracture patients. Among them, there were 5 patients (0.71%) who suffered from postoperative neurologic complications. In all patients, the surgery was performed with open reduction with insertion of $Medpor^{(R)}$. Clinical symptoms and signs were a little different from each other. Results: In case 1, the diagnosis was oculomotor nerve palsy. The diagnosis of the case 2 was superior orbital fissure syndrome, case 3 was abducens nerve palsy, and case 4 was idiopathic supraorbital nerve injury. The last case 5 was diagnosed as optic neuropathy. Most of the causes were extended fracture, especially accompanied with medial and inferomedial orbital blow-out fracture. Extensive dissection and eyeball swelling, and over-retraction by assistants were also one of the causes. Immediately, we performed reexploration procedure to remove hematomas, decompress and check the incarceration. After that, we checked VEP (visual evoked potential), visual field test, electromyogram. With ophthalmologic test and followup CT, we can rule out the orbital apex syndrome. We gave $Salon^{(R)}$ (methylprednisolone, Hanlim pharmaceuticals) 500 mg twice a day for 3 days and let them bed rest. After that, we were tapering the high dose steroid with $Methylon^{(R)}$ (methylprednisolon 4 mg, Kunwha pharmaceuticals) 20 mg three times a day. Usually, it takes 1.2 months to recover from the nerve injury. Conclusion: According to the extent of nerve injury after the surgery of orbital blow-out fracture, the clinical symptoms were different. The most important point is to decide quickly whether the optic nerve injury occurred or not. Therefore, it is necess is to diagnose the nerve injury immediately, perform reexploration for decompression and use corticosteroid adequately. In other words, the early diagnosis and treatment is most important.

A Change of fashin IIIustration by the Ideal Type of Human Body Beauty (인체미의 이상형에 따른 패션 일러스트레이션의 변화)

  • 전경숙
    • Journal of the Korean Society of Costume
    • /
    • v.28
    • /
    • pp.65-84
    • /
    • 1996
  • The purpose of this study is to analyze the relation between the beauty of human body and the fashion illustration in each period And I attained my object through the investigation of features and changes of illustration which is given a vivid description of the features and development of ideal humam body beauty. By various methods I studied this subject. Frist I refered to sundry records Secondly I investiated the fashion illustrations which are included in Vogue. On the basis of this data I grasped the ideal types of human body beauty which is founded during the social change in each 10 years. And I analyzed the relation be-tween the ideal type and fashion illustration which show the change of fashion. The summary of result is as follows. 1. In the early part of the 20th century the beauty of human body is represented with the figure of large-sized beauty which emphasize shoulder and bust. And fashion ikllustration show 9 life-size broad shoulder full bust lim waist and hourglass silhouette. 2, In the 1910s the swell of strength vanishes gradually and shoulder and sleeve are straight type. And fashion illustration show 7 life-size high waist line. And that is tublar sil-houette of high waist and streamline shape in which bust and hip are not emphasized. 3. In the 1920s the ideal type of human body beauty is straight type which shows flat bust and unexaggerate hip. And fashion illus-tration is about 8 life-size tublar silhouette of low waist and lunger and slimmer and young style in which bust and hip are not emph-asized. 4. In the 1930s the ideal is womamly slim and long style. Fashion illustration is about 8 life-size and slim & long silhouette in which waist line is emphasized and bust and hip line come out. 5. In the 1940s the ideal type is womamly style which has narrow shoulder rich bast and slim waist. And fashion illustration is about 7 life-size and hourglass silhouette which has unartificial shoulder slim waist and empha-sized bust. 6. In the 1950s the ideal type is that of ro-bust health which emphasize build and muscu-lar system. And fashion illustration is 8.5 life-size and show full bust and made waist slimmer. That is sheath silhouette. 7. In the child who has full face with large eyeball slender and long leg: narrow and immatured body comparatively big head. And fashion illus-tration is 7 life-size and show slim and long neck flat bust long and slim limbs and big head. That is H type silhouette. 8. In the 1970s the ideal type is high stat-ure flat breast small hip and wide shoulders. And fashion illustration is wide shoulders and slim waist as 11 life-size and straight sil-houete. 9. In the 1980s the ideal type is extremely emphasized breadth of shoulder because healthy body and muscle are recognized as the symbol of ideal attractiveness. And fashion il-lustration is about 8.5 life-size and show mus-cular slim type that is slim silhouette. 10 At the present time the ideal type is slim and tall type which is empasized healthy beauty. And fashion illustration is 12 life-size which has healthy body and skin So that is slim and long type.

  • PDF

Correlation of Refractive Error, Axial Length, Chamber Depth, Lens Thickness and Corneal Thickness of Normal University Students (정상 대학생의 눈 굴절이상, 안축장, 전방깊이, 수정체두께 그리고 각막두께의 연관성)

  • Kim, Chang-Sik;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To make a comparative study of correlation between biometry data of size in eyeball and refractive error. Methods: The subjects were 68 normal university students (male 36, female 32) and the average age was 22.85${\pm}$3.12. We measured the students' eyesight by A-scan ultrasound and refractor. The results were examined it's statistical significance by SPSS 12.0 version. Results: The mean of axial length was 24.31${\pm}$1.24 mm, chamber depth was 3.48${\pm}$0.28 mm, lens thickness was 3.56${\pm}$0.26 mm and corneal thickness was 0.55${\pm}$0.03 mm. Male's Axial length and chamber depth were larger than female's. As reflective error decreases the thickness of lens become thicker. The measurement data between right eye and left eye didn't had difference and there was no correlation with result of T-test. There were statistically significant correlation with length and chamber depth, axial length and corneal thickness, chamber depth and corneal thickness, and refractive error and lens thickness (p<0.01). Refractive error and axial length were minus linear regression (r=-0.56). Conclusions: Eye's refractive error was changed by axial length, chamber depth and lens thickness but it wasn't related with sex and whether it is a right eye or a left eye.

  • PDF

EFFECTS OF THE SITE AND THE EXTENT OF BLOWOUT FRACTURE ON ENOPHTHALMOS AND DIPLOPIA (Blowout 골절의 부위와 정도가 안구함몰 및 복시에 미치는 영향)

  • Hwang, Ung;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.292-300
    • /
    • 2004
  • Orbital blowout fractures are common consequence to blunt periorbital trauma. Pure orbital blowout fractures first occur at the weakest point of the orbital wall. Computed tomography(CT) is recognized to be the best imaging technique to evaluate orbital fractures. The extent and location of a blowout fractures in the CT scan were noted to have an effect on the clinical outcome. In the early posttraumatic period, the presence of significant enophthalmos is difficult to detect because of orbital edema. Early surgical intervention may improve the ultimate outcome because open reconstruction becomes more difficult if surgery is delayed. In this study, we evaluated isolated blowout fractures of the orbital floor by region-of-interest measurements from CT scans and their relationship to ophthalmologic findings. Six patients of the medial orbital wall fractures, eleven patients of the inferior orbital wall fractures, nineteen of the medial and the inferior orbital wall fractures confirmed by CT scan, were evaluated. The area of fracture and the volume of the displaced orbital tissue were determined from CT scan using linear measurements. Each of the calculated values for the area and the volume were compared with the degree of the enophthalmos, the diplopia, and the eyeball movement limitation to determine whether there was any significant relationship between them. The fracture area and the volume of the herniated orbital tissue were significantly positively correlated with the enophthalmos and the ocular motility limitation and not correlated with the diplopia. For the enophthalmos of 2mm or greater, the mean fracture area was 3.55{\pm}1.25cm^2$ and the volume of the herniated orbital tissue was $1.74{\pm}0.97cm^3$; for less than 2mm enophthalmos, $1.43{\pm}0.99cm^3$ and $0.52{\pm}0.49cm^3$, respectively. The enophthalmos of 2mm can be expected with $2.92cm^2$ of the fracture area and $1.40cm^3$ of the herniated orbital tissue. In conclusion, the enophthalmos of 2mm or more, which is a frequent indication for surgery. It can be expected when area of fracture is $2.92cm^2$ or more, or the volume of herniated orbital tissue is $1.40cm^3$ or more. And the CT scan using linear measurements has an application in the assessment of patients with blowout fractures and provides useful information in the posttraumatic evaluation of orbital fractures.

Development of FACS-based Android Head for Emotional Expressions (감정표현을 위한 FACS 기반의 안드로이드 헤드의 개발)

  • Choi, Dongwoon;Lee, Duk-Yeon;Lee, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.537-544
    • /
    • 2020
  • This paper proposes the creation of an android robot head based on the facial action coding system(FACS), and the generation of emotional expressions by FACS. The term android robot refers to robots with human-like appearance. These robots have artificial skin and muscles. To make the expression of emotions, the location and number of artificial muscles had to be determined. Therefore, it was necessary to anatomically analyze the motions of the human face by FACS. In FACS, expressions are composed of action units(AUs), which work as the basis of determining the location and number of artificial muscles in the robots. The android head developed in this study had servo motors and wires, which corresponded to 30 artificial muscles. Moreover, the android head was equipped with artificial skin in order to make the facial expressions. Spherical joints and springs were used to develop micro-eyeball structures, and the arrangement of the 30 servo motors was based on the efficient design of wire routing. The developed android head had 30-DOFs and could express 13 basic emotions. The recognition rate of these basic emotional expressions was evaluated at an exhibition by spectators.

Evaluation of the Fetal Dose during Prophylactic Placement of Internal Iliac Artery Balloon Occlusion Catheters in Placenta Accreta (유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가)

  • Kim, Dong-Sik;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.313-321
    • /
    • 2016
  • Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38~8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49~18.27 mGy.

Association between the C.O.G and E.O.G for Dynamic Postural Control of the Left Turn Motion on the Balance Beam (평균대 좌측 턴 동작시 동적 자세 조절에 미치는 C.O.G와 E.O.G 관계)

  • So, Jae-Moo;Kim, Yoon-Ji;Kim, Jae-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.49-58
    • /
    • 2009
  • This study aims to analyze the association between the center of mass(C.O.G) and ocular movement(E.O.G) according to the success and failure in the left turn motion on the balance beam, targeting three female gymnasts. When successful, the left-right C.O.G was moved to the left, which was a rotational direction until such time as the body rotated $180^{\circ}$, whereas there appeared to be a greater movement during failure; thus, it was shown to affect the maintenance of dynamic postural control. In case of the subsequent left-right turning motion of E.O.G, this matches the previous theory that the eyeball moves against the direction of rotation of the body. However, there was a difference at the time of movement, and a clear difference emerged in the success and failure in this study. Also, in the E.O.G in the up-down direction, a movement during failure showed a pattern of down direction in most cases; thus, it is deemed to affect the failure. Therefore, the kinetic postural control and E.O.G are supposed to affect the success and failure in a landing, which is the most importantly evaluated movement on the balance beam, in mutual association.

Experimental infection of Philasterides dicentrarchi in Juvenile Olive Flounder, Paralichthys olivaceus (양식넙치에서 분리된 스쿠티카 섬모충 Philasterides dicentrarchi의 넙치 치어 인위감염)

  • Jin Chang-Nam;Kang Hyun-Sil;Lee Chang-Hoon;Lee Young-Don;Lee Je-Hee;Song Choon-Bok;Heo Moon-Soo
    • Journal of Aquaculture
    • /
    • v.19 no.3
    • /
    • pp.197-204
    • /
    • 2006
  • The pathogenicity and infection route of the Scuticociliate, Philasterdies dicentrarchi, were investigated with the 3 and 5 cm-group of juvenile flounders, Paralichthys olivaceus. The infection rates of 3 cm-group were 40% four days post infection (D.P.I.) and increased to be 90.1% 24 D.P.I., whereas those of 5 cm-group were 20% 8 D.P.I., 42% 16 D.P.I., and 81% 24 D.P.I. The results showed there were several infection routes to internal organs Olive flounder. The first route was started with the infection at the soft part of caudal fin and later reached at fin ray and muscle tissue; the second one was started from lips and mouth tissue of upper jaw and later the pathogen could be observed at either muscle tissue or eyeball and brain; the third one was begun at caudal fin and later the pathogen reached at brain tissu'e through spiral cord; the fourth one was started with the infections at abdominal cavity and anus. P. dicentrarchi infected to brain tissue was first observed 14 D.P.I in 3 cm-group and 20 D.P.I. in 5 cm-group of the juvenile flounder. This indicated that the brain infection of P. dicentrarchi might occur faster in small-sized flounder than large-sized one.

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.