• Title/Summary/Keyword: Eye-glasses

Search Result 97, Processing Time 0.019 seconds

Implementation of User Gesture Recognition System for manipulating a Floating Hologram Character (플로팅 홀로그램 캐릭터 조작을 위한 사용자 제스처 인식 시스템 구현)

  • Jang, Myeong-Soo;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.143-149
    • /
    • 2019
  • Floating holograms are technologies that provide rich 3D stereoscopic images in a wide space such as advertisement, concert. In addition, It is possible to reduce the 3D glasses inconvenience, eye strain, and space distortion, and to enjoy 3D images with excellent realism and existence. Therefore, this paper implements a user gesture recognition system for manipulating a floating hologram characters that can be used in a small space devices. The proposed method detects face region using haar feature-based cascade classifier, and recognizes the user gestures using a user gesture-occurred position information that is acquired from the gesture difference image in real time. And Each classified gesture information is mapped to the character motion in floating hologram for manipulating a character action. In order to evaluate the performance of the proposed user gesture recognition system for manipulating a floating hologram character, we make the floating hologram display devise, and measures the recognition rate of each gesture repeatedly that includes body shaking, walking, hand shaking, and jumping. As a results, the average recognition rate was 88%.

The Study of Prevalence Rate of Refractive Error among the Primary Students in Jeollanamdo (전남지역 초등학생의 굴절이상 유병률에 관한 연구)

  • Jang, Jung Un;Park, Inn-Jee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.311-318
    • /
    • 2015
  • Purpose: This study was designed to investigate the prevalence rate of refractive error with gender and age presenting visual acuity of primary student in Jeonnam. Methods: Subjective refraction, objective refraction and visual acuity test were examined on 735 primary school children who ages of 8~13 years lived in Jenman. Presenting visual acuity test was using Han's visual acuity chart and objective refraction was carried out using auto-refractometer. Results: The presenting visual acuity was 0.1 worse in the eye of 54(7.3%) students and 49(7.3%) of them wearing the glasses. The rate of the wearing glasses were 79.3% in 0.125~0.25 visual acuity, 64.2% in 0.3~0.5 visual acuity and 61.6% in 0.6~0.8 visual acuity. It was appeared that 269(36.6%) of them were emmetropia, 321(43.7%) of them were myopia and 56(7.6%) of them were hyperopia, and 89(12.1%) of them were astigmatism. The prevalence rate of myopia was the highest and followed by the prevalence rate of astigmatism. The low degree of myopia occupied the most and the medium degree of myopia showed the tendency of increase as the students get olds. The prevalence rate of the hyperopia showed the tendency of decrease as the students get olds. The prevalence rate of with the rule astigmatism were 50.6% students and against the rule astigmatism were 48.3% of students. Conclusions: The present study reveals the considerable prevalence rates, 466(63.4%) of included subjects, of refractive errors among primary students in Jeonnam province. The rate of the wearing glasses were 313(42.6%). The prevalence of myopia increases as the students get older. Therefore students of visual management is considered necessary through the visual acuity test and refractive examination.

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

An Input/Output Technology for 3-Dimensional Moving Image Processing (3차원 동영상 정보처리용 영상 입출력 기술)

  • Son, Jung-Young;Chun, You-Seek
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.1-11
    • /
    • 1998
  • One of the desired features for the realizations of high quality Information and Telecommunication services in future is "the Sensation of Reality". This will be achieved only with the visual communication based on the 3- dimensional (3-D) moving images. The main difficulties in realizing 3-D moving image communication are that there is no developed data transmission technology for the hugh amount of data involved in 3-D images and no established technologies for 3-D image recording and displaying in real time. The currently known stereoscopic imaging technologies can only present depth, no moving parallax, so they are not effective in creating the sensation of the reality without taking eye glasses. The more effective 3-D imaging technologies for achieving the sensation of reality are those based on the multiview 3-D images which provides the object image changes as the eyes move to different directions. In this paper, a multiview 3-D imaging system composed of 8 CCD cameras in a case, a RGB(Red, Green, Blue) beam projector, and a holographic screen is introduced. In this system, the 8 view images are recorded by the 8 CCD cameras and the images are transmitted to the beam projector in sequence by a signal converter. This signal converter converts each camera signal into 3 different color signals, i.e., RGB signals, combines each color signal from the 8 cameras into a serial signal train by multiplexing and drives the corresponding color channel of the beam projector to 480Hz frame rate. The beam projector projects images to the holographic screen through a LCD shutter. The LCD shutter consists of 8 LCD strips. The image of each LCD strip, created by the holographic screen, forms as sub-viewing zone. Since the ON period and sequence of the LCD strips are synchronized with those of the camera image sampling adn the beam projector image projection, the multiview 3-D moving images are viewed at the viewing zone.

  • PDF

A Survey on Back Pain of Nurses (간호활동의 유형과 요통 발생에 관한 일 조사연구)

  • 한윤복
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 1977
  • Despite the fact that it is not a fatal symptom. the lower back pain of human species is considered a health problem of modern society: 80% of world population experience it and the distress and dysfunction caused by interferes daily life as well as the general productivity. This study was performed to investigate the general tendency of lower back Pain on nurses: influence of nursing activities, working condition and the physical characteristics of nurses on the pain in order to provide data for prevention and treatment. 386 nurses working at 16 general hospitals throughout the country were sampled. Questionaries developed by the researcher was used for data gathering. Results are as follows : 1. Lower back pain was experienced by most(72.3%) of the nurses: the highest rate of -Pain experience was revealed to be the a9e group of 35-39 (80.8%) followed by 25-29 group (74.2%). 2. In almost all instances (91.4%), the first pain attack occurred before the age of 29, and in 73.1%. the attack occurred between the age of 15-24. 3. In 10.1%, the pain was almost persistent or occurred every other day frequency. In 9%, the pain was relieved by the administration of analgesics or "unable to move". 4. More than 6 days′sick leave due to the pain revealed to be in 2.2%. No significant difference was revealed between specialities of service. 5. Pain experience and the over or under weight revealed not to have significant relations. (X$^2$=0.55224, p〉0.7587) 6. The length of working hour of I. C. U. and O. R, revealed to be longer than that of nurses general ward, however. no significant difference on the rate of pain occurrence apparent. (X$^2$=0.4952, p〉0.8239) No significant difference on the rate of pain occurrence between nurses working over 46 hours/week and under 45 hours/week. (X$^2$=3.86241, p〉0.078318) 7. The most frequent Pain related movement revealed to be "lifting patient or heavy object" (24. 7%, N=68) followed by "the sameness of position, either standing or sitting"(16.8%) 8. Regular physical exercise revealed to have no significant influence on the rate of Pain occurrence. 9. Higher raft of pain experience was revealed in the group of nurses wearing eye glasses. Uncomfortable shoes revealed to have influenced the pain. 10. The most frequent pain relieving treatment revealed to be "rest" (54.2%, N= 151) followed by "analgesics" (12.6%, N=35) and "hot compress/fomentation"(10.5%, N=29). In 13.7% (N=38) no special care was given.

  • PDF

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF