• Title/Summary/Keyword: Eye-Safe Laser

Search Result 11, Processing Time 0.029 seconds

Distance measurement using pulsed eye-safe laser (펄스형 eye-safe 레이저를 이용한 거리측정)

  • 유병헌;조성학;장원석;김재구;황경현;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.106-109
    • /
    • 2004
  • In this project, we have developed the eye-safe LRF system of 1.54 ${\mu}{\textrm}{m}$ wavelength using OPO. The maximum measured distance was 3.7km in outdoor experiment. We used Nd:YAG (1064nm) as a laser medium. It was applied BBO to construct the system. We also developed a time-counter for the range finder using a method of TOF (time of flight). The counter-clock used at the time counter was 320MHz making resolution within $\pm$1m. Start and stop signals were detected by two channel systems using PIN and APD. The LRF's repetition rate was 4 times per minute. The energy was measured to be over 9mJ. And, pulse-duration was 23ns. Resolution was $\pm$2m at the distance measurement using a target.

  • PDF

Design of a Single Pulse Laser Range Finder with Er:Yb:glass Microchip Lasers (어븀:이터븀:유리 마이크로칩 레이저를 이용한 단펄스 거리측정기 설계)

  • Koh, Hae Seog;Lee, Chang Jae;Park, Choong Bum;Jeon, Hyoung Ha;Ahn, Pil Dong;Park, Do Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.295-305
    • /
    • 2018
  • We present a passively Q-switched monolithic Er:Yb:glass microchip laser developed in our lab. The microchip laser can produce pulses at 1535 nm of the 'eye-safe' wavelengths with the pulse energy of 50 uJ and the pulse width of 4-6 ns. Using the laser we also designed and developed a pulsed Er:Yb:glass microchip laser rangefinder. Expressions for background and signal power, noise, and signal-to-noise ratio are reviewed. A computer simulation was used to optimize laser power, receiver aperture, and preamplifier bandwidth for the efficient system design of the laser rangefinder. Experimental results are presented to compare with the theory.

Safe Use of Medical Lasers

  • Woo, Seung Hoon;Chung, Phil-Sang;Lee, Sang Joon
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.68-75
    • /
    • 2021
  • Medical lasers have been widely used for various diseases. Despite the notable benefits, lasers could cause several complications such as skin burn, eye injury, airway fire, and so on. These accidents may occur not only with patients, users of the laser, or laser handlers but also to people passing in front of the laser treatment room. Although there is a risk associated with the laser, most of them can be prevented through good training, use of proper protection equipment, and ensuring the safe operation of the laser at all times. Due to the increasing use of lasers and the growing interest in their use, medical institutions should particularly emphasize the safe use of lasers and introduce systems for laser safety.

Development of range finder using long wavelength laser (장파장 레이저를 이용한 거리 측정기 개발)

  • 유병헌;신보성;장원석;김재구;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.938-941
    • /
    • 2003
  • As the application area of range finder initially developed for military purpose has been extended, the necessity of precision measurement for long distance and its miniaturization is being presented. Recently, LRF(Laser Range Finder) is widely used because it shows more accurate results of range finding. However, most of LRFs use laser source which have wavelength ranges harmful to the human eyes. In this study, we developed the LRF using OPO(Optical Parametric Oscillator) which can stretch laser wavelength to safe region and realized more compact one using solid state laser

  • PDF

Infrared-to-blue Upconversion in Tm-doped Oxyfluoroborate Glasses (Oxyfluoroborate 유리재료에서의 적외선-청색 상방 형광발생)

  • P. Babu;Lee Seon-Gyun;Van-Thai Pham;Im Gi-Su;Seo Hyo-Jin;C. K. Jayasankar
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.116-117
    • /
    • 2002
  • In recent years, there has been an increasing interest in $Tm^{3+}$ doped crystals and glasses due to their potential applications as near infrared lasers and infrared to visible upconversion lasers for use in different fields such as medical surgery, eye safe laser radar, data storage, barcode reading and so on. Thulium ions have stable excited levels suitable for emitting blue upconversion fluorescence. (omitted)

  • PDF

Predictors of Success of Selective Laser Trabeculoplasty Adjusted for Intraocular Pressure Variations (단안 선택적 레이저섬유주성형술에서 안압 변동을 보정한 성공예측인자의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1166-1172
    • /
    • 2018
  • Purpose: To investigate the efficacy, and identify predictors of success of selective laser trabeculoplasty (SLT) in open-angle glaucoma (OAG) patients after adjusting for intraocular pressure (IOP) changes in the untreated fellow eye. Methods: This retrospective chart review included 52 eyes of 52 OAG patients who underwent SLT in one eye and were followed-up for at least 1 year after the procedure. The IOP was measured before the treatment, at 1, 2, and 3 months posttreatment, and every 3 months thereafter. To account for the possible influence of IOP fluctuations on laser outcomes, post-laser IOP values of the treated eye of each patient were also analyzed, after adjusting for IOP changes in the untreated fellow eye. Success was defined as an IOP decrease ${\geq}20%$ of the pretreatment IOP. The success rate was determined based on Kaplan-Meier survival analysis and factors predictive of success were analyzed using the Cox proportional hazard model. Results: The mean pretreatment IOP was $23.17{\pm}6.96mmHg$. The mean IOP reduction was $5.59{\pm}4.78mmHg$ (29.7%) and the success rate was 65.4% at 1 year. The adjusted mean IOP reduction was $4.70{\pm}4.67mmHg$ (23.9%) and the adjusted success rate was 53.9%. Pretreatment IOP was associated with SLT success; the higher the pretreatment IOP, the greater the post-laser IOP reduction (p = 0.025). Age and mean deviation index did not show a significant association with SLT success (p = 0.066 and p = 0.464, respectively). Conclusions: SLT is a safe and effective alternative method of IOP reduction in OAG patients. Herein, pretreatment IOP was the only factor significantly associated with SLT success. IOP fluctuations of the untreated eye should be considered for a better understanding of the impact of treatment.

Direct Geo-referencing for Laser Mapping System

  • Kim, Seong-Baek;Lee, Seung-yong;Kim, Min-Soo
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.423-427
    • /
    • 2002
  • Contrary to the traditional text-based information, 4S(GIS,GNSS,SIIS,ITS) information can contribute to the citizen's welfare in upcoming era. Recently, GSIS(Geo-Spatial Information System) has been applied and stressed out in various fields. As analyzed the data from GSIS arena, the position information of objects and targets is crucial and critical. Therefore, several methods of getting and knowing position are proposed and developed. From this perspective, Position collection and processing are the heart of 4S technology. We develop 4S-Van that enables real-time acquisition of position and attribute information and accurate image data in remote site. In this study, the configuration of 4S-Van equipped with GPS, INS, CCD and eye-safe laser scanner is shown and the merits of DGPS/INS integration approach for geo-referencing is briefly discussed. The algorithm of DGPS/INS integration fur determination of six parameters of motion is eccential in the 4S-Van to avoid or simplify the complicated computation such as photogrammetric triangulation. 4S-Van has the application of Laser-Mobile Mapping System for three-dimensional data acquisition that merges the texture information from CCD camera. The technique is also applied in the fields of virtual reality, car navigation, computer games, planning and management, city transportation, mobile communication, etc.

  • PDF

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.