• Title/Summary/Keyword: Eye point

Search Result 340, Processing Time 0.026 seconds

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique (컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구)

  • Seoung, Youl-Hun;Rhim, Jea-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

Evaluation of the Head Mouse System using Gyro-and Opto-Sensors (각속도 및 광센서를 이용한 헤드 마우스의 평가)

  • Park, Min-Je;Kim, Soo-Chan
    • Journal of the HCI Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.1-6
    • /
    • 2010
  • In this research, we designed the head mouse system for disabled and gamers, a mouse controller which can be controlled by head movements and eye blinks only, and compared its performance with other regular mouse controller systems. The head mouse was moved by a gyro-sensor, which can measure an angular rotation of a head movement, and the eye blink was used as a clicking event of the mouse system. Accumulated errors caused by integral, which was a problem that previous head mouse system had, were removed periodically, and treated as dead zones in the non-linear relative point graph, and direct mouse point control was possible using its moving distance and acceleration calculation. We used the active light sources to minimize the influence of the ambient light changes, so that the head mouse was not affected by the change in external light source. In a comparison between the head mouse and the gazing tracking mouse (Quick Glance), the above method resulted about 21% higher score on the clicking event experiment called "20 clicks", about 25% higher on the dasher experiment, and about 37% higher on on-screen keyboard test respectively, which concludes that the proposed head mouse has better performance than the standard mouse system.

  • PDF

Medial Canthopexy using Modified Hiraga's Incision for Correction of Traumatic Telecanthus (외상성 내안각격리증 환자에 있어 Hiraga 절개법을 이용한 내안각 고정술)

  • Lim, Jong-Hyo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Jun-Ho
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.504-508
    • /
    • 2010
  • Purpose: Traumatic telecanthus can result from nasoethmoid-orbital fractures. Repair of the medial canthal tendon (MCT) using transnasal wiring is regarded as a choice of method to treat telecanthus, however, is often complicated by incomplete anchoring and drift of canthus, extrusion of wire, in-fracture of orbital bone, and eye damage. The authors introduced oblique transnasal wiring method through the Hiraga's epicanthopalsty incision instead of well-known classical bicoronal approach. Methods: Five patients with traumatic telecanthus were treated with this method. Though the Hiraga's epicanthoplasty incision, we could approach the operative field; the medial orbital wall and detached MCT. Oblique transnasal wiring was performed as following steps. After slit skin incision on the contralateral nasal recession area, drill holes were made from this point to the superior and posterior point of lacrimal sac of deformed eye. A 2-0 wire was double-passed through the holes and MCT. Traction was applied to ensure pulling the MCT and the wires were twisted in the contralateral nose, securing the MCT in the correct position. Results: All patients except 1 person showed improvement and rapid recovery. On average each canthus was moved 5.6 mm medially. In all cases, there were no eyelashes disappear, lacrimal canaliculitis, lacrimal duct injury, or infections. Conclusion: The Hiraga's epicanthoplasty incision could give sufficient operative field to reattach the MCT in traumatic telecanthus patients. And the oblique transnasal wiring technique is effective for the Asians who have flat nose and exophthalmic eye. The authors conclude that this technique could be a simple, safe and scarless method to correct traumatic telecanthus.

Change of electroencephalograph during 3-dimensional image load (입체 TV 영상(3D) 주시시의 유발전위)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.29-35
    • /
    • 1990
  • To investigate and analyze of the human brain-wave changes during 3-dimenslonal image load were expected to take not only an important basic information of 3-dimensional TV usage but also 3-dimensional image design. In this experiment, to analyze the difference of visual analyze handing system for which we present the 2- dimensional image having no parallex and 3-dimensional image by visual evoked potentials(VEP). 2-dimensional image and 3-dimensional image displayed on the screen through video. In the test, the time interval was one sec for presentation of stimulus considering united time of visual information of right eye and left eye during watching the 3-dimensional image also display time interval was 200 mesc for each stimulus image. Results are as follow, (1) N190 appears faster 16msec-20msec in the point of Fz, Cz, Pz, Oz when loaded 3D4 angle than 2D3 angle. (2) About of the P300, 3D4 angle(Otherwise, Oz point was reverse) and in the case of no equipment of liquid crystal shutter, there appeared PEAK near the P250. (3) There were 5% significant difference when the liquid crystal shutter was equiped and didn't, Therefore, this phenomenon show the possibility that Liquid crystal shutter influences on Visual Evoked Potentials.

  • PDF

Development of Pointing Device on Digital Display (EOG를 이용한 디지털 화면상의 방향지시기 개발)

  • Park, Jong-Hwan;Cheon, Woo-Young;Park, Hyung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.484-486
    • /
    • 1998
  • In this paper, a new method for controlling the pointing device on digital display using EOG(electrooculogram) which is generated from eye movement, was suggested. The manufactured system is consisting of pre-amplifier, A/D converter, serial transmission device and PC program. The EOG is amplified by pre-amplifier. And the amplified EOG is digitized and transmitted to personal computer via rs-232c by PIC16C74A. Finally, the software for controlling the pointer on digital display is developed on computer. As the result, the error between the real subject's viewing point and the point indicated by the developed pointing device on digital display was investigated into the average value, 0.72 degree for horizontal axis, 0.96 degree for vertical axis. The pointing device developed in this study is controlled by subject's eye movement, that is, the user's intention. Furthermore, the algorithm of this study is applicable for many field such as a new method remote control, a new wheelchair control and so forth.

  • PDF

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

An Analysis of Optical Performance of the Finite Schematic Eye According to Iris Eccentricity and Visual Axis change (시축 변화와 홍채 편심에 따른 정밀모형안의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.151-154
    • /
    • 2010
  • Purpose: We investigated how the movement of iris and visual axis affects the finite schematic eye Methods: Using the schematic eye with the crystalline lens in the existing forms of the radial GRIN and the spherical GRIN, the iris centre was moved 0.5 mm in nasal direction and visual axis was tilted $5^{\circ}$ in same direction, with the additional degree of 2.5 down to locate the focal point in fovea. This study analyzed performance change of the optical system, designing it same as the real eye. Results: The whole aberration distribution showed a considerable difference in performance in comparison with the real eye; the biggest difference shown at the central field of optical system. The spherical aberration showed the biggest difference, and a peripheral power error and field curvature leaned toward (+) direction in aberration distribution. Conclusions: When designing the schematic eye with the performance similar with that of the real eye by taking into consideration the iris centre and visual axis, the aberration at the center field of optical system in particular should be corrected. Spherical aberration which showed the biggest difference should be corrected in the first place. In addition, a peripheral power error and field curvature that leaned toward (+) direction should be moved toward (-) direction.

Generation of a practical visual field for the design and evaluation (제품설계와 평가를 위한 시각영역의 생성)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Depending upon the eye and head movement, the visual field is often classified into three categories ; stationary field, eye field and head and eye field. To investigate the effect of background condition on the size of the visual field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the perimeter modified to cover the range of 330 .deg. around the fixation point, with the visual angle subtended 1.4 .deg. vertically and horizontally. Nontarget density, meridian, size contrast and subject showed a significant effect on the visual field at .alpha. =0.01, where density was inversely proportional to the size of the visual field, and size contrast linearly proportional to the size of the visual field. The size of the visual field on horizontal axis was larger than that on vertical axis, and that on right and upper meridian was also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. In addition, the regression equations to predict the visual field on the given background condition were suggested. These results were expected to be used as a design guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc.

  • PDF

A study on the consumer's visual reaction about display props of clothing store - Focus on visual behavior using eye-tracker - (의류매장 디스플레이 소도구에 대한 소비자의 시각반응 연구 - 아이트래커를 활용한 시각행동 중심으로 -)

  • Kim, Young-Me;Kim, G-Ho
    • Journal of Fashion Business
    • /
    • v.14 no.5
    • /
    • pp.35-48
    • /
    • 2010
  • As measuring visual behavior by utilize eye-tracker, this study examines whether consumer concentrates on visual attention with certain object and measures visual behavior with fixation number, fixation duration, the first fixation, which are visual attention pattern of consumer about Mannequin, hanger, shelve as props of display advertising effect on clothing store. It has experimental purpose to recognize relationships in terms of regardless, appropriateness, purchase intention. During display of clothing store, first experimental consequence to measure visual behavior on consumer did appear to allocate more cautions than other props. Second, in terms of relationships with regardless, appropriateness, purchase intention from consumer, each fixation pattern about consumer's fixation number, fixation duration, the first fixation was confirmed that there is meaningful correlation with each other. Accordingly, as advertising effect of mannequin makes consumer to concentrate more visually cautious, it is translated that high favor about display product with mannequin has positive role on purchase intention. Also, there is a purpose that higher feasibility on study result provides practical point on clothing store's display marketing strategy of corporation.