• Title/Summary/Keyword: Eye movement program

Search Result 45, Processing Time 0.019 seconds

Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients (PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링)

  • Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Seo, Sang Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

Comparison between Subjective Scoring and Computer-Based Asymmetry Assessment in Facial Nerve Palsy

  • Lee, Doh Young;Kim, Hyun Seok;Kim, So Young;Park, Kwang Suk;Kim, Young Ho
    • Journal of Audiology & Otology
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Background and Objectives: The aim of the present study was to assess the feasibility of a PC-based facial asymmetry assessment program (PC-FAAP) and to compare the results of PC-FAAP with subjective regional scoring by raters in acute unilateral peripheral facial nerve paralysis (FNP). Subjects and Methods: Participants were divided into 3 groups with 8 participants per group: group I, normal; group II, mild to moderate FNP; and group III, severe FNP. Using the PC-FAAP, the mouth asymmetry ratio (MAR), eyebrow asymmetry ratio (EAR), and complete eye closure asymmetry ratio (CAR) were calculated by comparing the movement of tracking points on both sides. The FNP grading scale (FGS) integrated each score, and the scores were weighted with a ratio of 5:3:2 (MAR:CAR:EAR). Subjective regional scoring was measured on a 0-100 scale score by three otologists. PC-FAAP and subjective scoring were compared in each group regarding the consistency of the results. Results: The mean scores of the MAR, EAR, CAR, and FGS of each group were significantly different. PC-FAAP showed significant differences between the three groups in terms of MAR, EAC, CAR, and FGS. PC-FAAP showed more consistent results than subjective assessment (p<0.001). The PC-FAAP was significantly more consistent in group I and group III (p<0.001 and p=0.002, respectively). FGS in group III was the only parameter that showed a more consistent result in PC-FAAP than the subjective scoring (p=0.008). Conclusions: An FNP grading system using a PC-based program may provide more consistent results, especially for severe forms.

Comparison between Subjective Scoring and Computer-Based Asymmetry Assessment in Facial Nerve Palsy

  • Lee, Doh Young;Kim, Hyun Seok;Kim, So Young;Park, Kwang Suk;Kim, Young Ho
    • Korean Journal of Audiology
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Background and Objectives: The aim of the present study was to assess the feasibility of a PC-based facial asymmetry assessment program (PC-FAAP) and to compare the results of PC-FAAP with subjective regional scoring by raters in acute unilateral peripheral facial nerve paralysis (FNP). Subjects and Methods: Participants were divided into 3 groups with 8 participants per group: group I, normal; group II, mild to moderate FNP; and group III, severe FNP. Using the PC-FAAP, the mouth asymmetry ratio (MAR), eyebrow asymmetry ratio (EAR), and complete eye closure asymmetry ratio (CAR) were calculated by comparing the movement of tracking points on both sides. The FNP grading scale (FGS) integrated each score, and the scores were weighted with a ratio of 5:3:2 (MAR:CAR:EAR). Subjective regional scoring was measured on a 0-100 scale score by three otologists. PC-FAAP and subjective scoring were compared in each group regarding the consistency of the results. Results: The mean scores of the MAR, EAR, CAR, and FGS of each group were significantly different. PC-FAAP showed significant differences between the three groups in terms of MAR, EAC, CAR, and FGS. PC-FAAP showed more consistent results than subjective assessment (p<0.001). The PC-FAAP was significantly more consistent in group I and group III (p<0.001 and p=0.002, respectively). FGS in group III was the only parameter that showed a more consistent result in PC-FAAP than the subjective scoring (p=0.008). Conclusions: An FNP grading system using a PC-based program may provide more consistent results, especially for severe forms.

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

Application Strategies of Eye-tracking Method in Nightscape Evaluation (야간경관 평가에서의 아이트래킹 분석 적용 연구)

  • Kang, Youngeun;Kim, Mintai
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.87-97
    • /
    • 2015
  • There's a trend towards vitalization of nightscape planning businesses nationally and locally as well for city image making and activation of regional economy, but there is still no systematic nightscape planning going on for lack of relevant researches and objective evaluations. This study aims to suggest the guideline for nightscape planning by conducting an eye tracking experiment and survey for recognizing the characteristics of a nightscape. Furthermore, the authors intended to verify the eye-tracking method as a tool for landscape evaluation. The research site was restricted in the campus of Virginia Tech, VA, and those were selected by experts' survey among various types of nightscape images. The variables for analyzing the characteristics of nightscape images selected were 'preference', 'safety(fear)' and 'clearness'. 'Fixation duration', 'saccade duration', 'scan path length', and 'pupil size' were selected as the eye movement measurements. The results of this study are as follows: The first outcome found was that there were significant differences among the characteristics(preference, safety and clearness) of a nightscape by MANOVA, and these variables were correlated positively by Pearson's correlation. Secondly, there were differences on fixation duration, saccade duration and scan path depending on the nightscape setting statistically. Also, the eye tracking measurement in an open setting was recorded lower than enclosed settings. In the result of a heat map, we found the meaning of the fixated areas on both viewing without intention and viewing intentionally. It turned out that the fixated areas were consistent with the areas the subjects felt preferred and clarity in all of the nightscape images, which means people usually focus on what they prefer and see clearly in a certain nightscape. Based on this result and previous studies, the authors could make a conclusion that eye tracking method can apply to evaluate nightscape settings in terms of analyzing the whole characteristics and finding specific points for the detailed analysis as well. Therefore, these results can contribute by suggesting nightscape planning, implication of the landscape evaluation, and implication of the eye tracking study.

Parafoveal Preview Effects on Semantic Relatedness in Eye Movement Tracking (안구운동 추적을 통해 살펴본 중심와주변 정보의 의미적 관련 정도에 따른 미리보기 효과)

  • Wang, Shang;Choo, Hyeree;Koh, Sungryoung
    • Korean Journal of Cognitive Science
    • /
    • v.35 no.2
    • /
    • pp.129-159
    • /
    • 2024
  • In the process of reading, readers can process information not only within the fixated region, known as the fovea, but also in the parafoveal region to the right of the fovea. While the parafoveal semantic preview effect has been confirmed in eye-tracking experiments using boundary techniques, research on how the parafoveal preview effects differ depending on the degree of semantic relatedness is still limited. This study investigates the parafoveal preview effects as a function of semantic relatedness with the target word. The experiment utilized Korean-Chinese bilinguals and presented mixed-language sentences as experimental stimuli. Four parafoveal preview conditions were applied to the target words in each sentence: (1) Korean identical condition, where the parafoveal word was the same as the target word (e.g., "나라," meaning "country" in English), (2) Chinese synonymous condition, where the parafoveal word had the same meaning as the target word (e.g., "国家," also meaning "country" in English), (3) Chinese semantically related condition, where the parafoveal word was semantically related to the target word (e.g., "政权," meaning "political power" in English), and (4) Chinese unrelated condition, where the parafoveal word was semantically unrelated to the target word (e.g., "围裙," meaning "apron" in English). The study explored the parafoveal preview effect in terms of the degree of semantic association with the target word. We found the most pronounced preview effect in conditions where the preview and the target word shared the same meaning, and we also observed preview effects in conditions where the semantic relatedness with the target word was relatively weak. This study suggests that the degree of semantic relatedness between the parafoveal preview word and the target word can influence readers' reading processes. It contributes to a better understanding of readers' eye movements and comprehension processes, with potential implications for the development of effective reading strategies and educational methods.

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.

A Study on the Correlation between Visual Perception Ability and Balance Ability in the Health Elderly (노인의 시지각 능력과 균형능력과의 상관관계에 관한 연구)

  • Jang, Yong-Su;Park, Chang-Sik;Lee, Hyoung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the correlation between the visual perception ability and the static dynamic balance ability in health elderly. Method: The Motor Free Visual Perception Test-Row Score(MVPT-RS) and MVPT-Process Time(MVPT-PT) were used for evaluating the visual perception abilities. Assessment of the balance ability was taken by using Good Balance System. In the assessment using Good Balance System, X, Y coordinate speed, anterior-posterior direction, medial-lateral direction and Velocity Movement(VM) in standing posture when eye open were measured as static balance abilities. Thirty-seven healthy elderly who live in Gwangyang participated in the experiment for 2 months, from October to November 2010. Results: 1. There were statistically significant differences of MVPT-RS, MVPT-PT, NSB-X, NSB-Y, NSB-VM, OLB-X, and OLB-VM based on the gender(p<0.05). 2. The negative correlations of MVPT-RS:NSB-Y(r=-0.354), MVPT-RS:OLB-X(r=-0.4), MVPT-RS: OLB-Y(r=-0.371), but positive correlations of MVPT-PT:DTB-T showed a statistical significance(r=0.45, p<0.05). 3. The positive correlations of NSB-X:NSB-Y(r=0.54), NSB-X: NSB-VM(r=0.848), NSB-Y:NSB-VM(r=0.531), OLB-X:OLB-Y(r=0.876), OLB-X:OLB-VM(r=0.872), and OLB-Y:OLB-VM(r=0.787) showed statistical significances(p<0.05). Conclusion: These results showed that the visual perception ability was correlated with some balance ability in health elderly. Especially the perception test process time(MVPT-PT) has closely related with the DTB-T. The visual perception ability is considered as a factor on the balance ability in health elderly. Further study will focus on the development of improving program of visual perception ability as an improving method of balancing ability in health elderly.

  • PDF

Morphological Parafoveal Preview Benefit Effects in Reading Korean (우리글 읽기에서 형태소정보의 미리보기 효과)

  • Lee, Sangeun;Choo, Hyeree;Koh, Sungryong
    • Korean Journal of Cognitive Science
    • /
    • v.31 no.2
    • /
    • pp.25-54
    • /
    • 2020
  • While there is no evidence for parafoveal processing in alphabetic languages such as English and Finnish, there is some evidence that morphological information is processed in syllabic languages like Chinese. Korean writing system, Hangul, would be able to provide morphological preview benefit effects since it is an "alphabetic syllabary" which contains both alphabetic and syllabic features. This study explored morphological parafoveal preview benefit effects during reading Korean using irregular verbs, which have phonological and orthographical differences between fundamental and conjugated forms. In the Experiment, the target word was irregular conjugated form, and there were four preview conditions: identical (e.g. 구워), fundamental form (e.g. 굽다), orthographically related (e.g. 굼다), and unrelated control (e.g. 죨어). In the result of study, identical was shortest and morphological, orthographical, unrelated preview were followed. Moreover, measures of first-pass reading of morphological preview were significantly shorter than those of unrelated control preview. This results support the hypothesis of morphological preview benefit effects in Korean. The implications of the results are discussed.

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF