• Title/Summary/Keyword: Eye contact

Search Result 211, Processing Time 0.026 seconds

Depth Video Post-processing for Immersive Teleconference (원격 영상회의 시스템을 위한 깊이 영상 후처리 기술)

  • Lee, Sang-Beom;Yang, Seung-Jun;Ho, Yo-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6A
    • /
    • pp.497-502
    • /
    • 2012
  • In this paper, we present an immersive videoconferencing system that enables gaze correction between users in the internet protocol TV (IPTV) environment. The proposed system synthesizes the gaze corrected images using the depth estimation and the virtual view synthesis algorithms as one of the most important techniques of 3D video system. The conventional processes, however, causes several problems, especially temporal inconsistency of a depth video. This problem leads to flickering artifacts discomforting viewers. Therefore, in order to reduce the temporal inconsistency problem, we exploit the joint bilateral filter which is extended to the temporal domain. In addition, we apply an outlier reduction operation in the temporal domain. From experimental results, we have verified that the proposed system is sufficient to generate the natural gaze-corrected image and realize immersive videoconferencing.

Factors influencing the quality of life by dry eyes of university students (대학생의 안구건조가 삶의 질에 미치는 요인)

  • Jung, Eunja;Lee, Yumi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.170-174
    • /
    • 2021
  • The purpose of this study is descriptive survey to quality of life by dry eyes experience in university students. The Korean version of the National eye institute visual functioning questionnaire (NEI-VFQ) was used to evaluate the quality of life. As a result of the study, 18.4% of the participants were diagnosed with dry eyes, and 63.2% experienced subjective dry eyes experience. The findings showed that the factors influencing the visual quality of life was wearing glasses, and the explanatory power for this 13.6%. Further research is needed considering the length of wearing glasses, contact lenses and severity of dry eyes.

Exploring the Key Priority of V2H Communication Technology Using the KANO Model (KANO 모델을 활용한 V2H 커뮤니케이션 기술의 우선순위 분석)

  • SangHwa, Lee;SooHee, Kang;Jeong Ah, Jang
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.4
    • /
    • pp.91-99
    • /
    • 2022
  • In Korea, various studies on autonomous vehicles are being conducted with the aim of commercializing the fully autonomous driving (Lv.4) on major roads in 2027. Currently, the communication between non-autonomous vehicles and road users is made with gestures, eye contact, and verbal signals. In the case of autonomous vehicles in the future, autonomous vehicles should communicate instead of drivers. Recently, V2H communication technology (communication technology between autonomous vehicles and road users) is being developed. This study shows technology priorities using the KANO model in caution (warning) and traffic (concession) situations. As a result, a total of six attractive quality technologies were analyzed: technology to provide dark warning information in a display graphic; technology to provide dark warning information in a projection graphic; technology to provide light concession information in a display graphic; technology to provide dark concession information in a display graphic. In the future, it will investigate the preference of users in providing V2H information by road situation. It will be used as a V2H design priority.

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.

Thermographic Assessment on Temperature Change of Eye Surface in Cataract Surgery Observation (백내장수술 안에서 열화상카메라를 이용한 안구표면 온도의 변화)

  • Park, Chang Won;An, Young-Ju;Kim, Hyojin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.497-504
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the temperature changes of the ocular surface before and after cataract surgery using thermography of a thermal imaging camera. Methods : The study included 75 patients (75 eyes) aged from 50 to 79 years who underwent cataract surgery. In the past, those who underwent corneal-related surgery, wearing contact lens, disorder of tear secretion and taking medication for systemic disease were excluded from this study. The temperature changes of the eyeball surface were measured using a thermal imager (Cox CX series, Answer, Korea) following Tear Break Up Time (TBUT) test, Mcmonnies questionnaire and Schirmer's Test in real time, Results : While the temperature of preoperative ocular surface was $35.20{\pm}0.54^{\circ}C$ and that of postoperative temperature was $35.30{\pm}0.53^{\circ}C$, the difference was not significant. The temperature changes in the ocular surface were statistically significant at $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) before the surgery and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) after the surgery. In comparison of the age groups, it was shown that the changes in the surface temperature before the surgery were from $-0.19{\pm}0.05{\Delta}$ ($^{\circ}C/sec$) to $-0.14{\pm}0.09{\Delta}$ ($^{\circ}C/sec$) in the 50s group, and from $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) to $-0.15{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) in 60s group, and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C$) to $-0.12{\pm}0.08{\Delta}/sec$) in the 70s group, showing significant changes in the ocular surface temperature at all ages. Conclusion : Following the cataract surgery, all the indicators of dry eye syndrome were decreased, and eye surface temperature changes were significant. The thermography technique of the ocular surface would be expected to be useful for the evaluation of various dry eye syndromes because it is easy to evaluate dry eye syndrome noninvasively and can be quantified.

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF

Vibration of Contact Lenses (콘택트 렌즈의 진동에 관한 연구)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.13-29
    • /
    • 2001
  • A mathematical model was proposed to analyze the vibration of diaphragm, such as the contact lenses fitted on the eyes, being subjected to the external sinusoidal pressure. The model incorporates the differential equations and their numerical solution program, based on the wave equations. Turbo-C and graphic software, formulated to describe the dependence of the various parameters involved in the vibration. The model predicts the radial distribution of amplitude, frequency dependence of both average displacement amplitude and the power of diaphragm whose edge is being either simply supported or rigidly clamped in vibration. The effect of variables such as thickness, radius, damping coefficients on the vibration characteristics was illustrated by the computer simulation of the derived program. As the frequency of driving pressure increases above the certain value determined by the boundary conditions and parameters the wave shape or pattern changes from simple arc to belly or loops having double antinode. It seems that the effect of outer antinode progressively increases as the frequency increases. If this kind of phenomena occurs to the contact lens on the cornea in vivo, it may cause an abnormal correction power in the lenses or pull off the eye due the increased rise of outer part of the lens.

  • PDF

A Study of Columnar Joint in Goheung, Jeollanam-do, Korea (전라남도 고흥지역에 분포하는 주상절리에 관한 연구)

  • Son, Jeong-Mo;Ahn, Kun Sang
    • Journal of the Korean earth science society
    • /
    • v.37 no.6
    • /
    • pp.332-345
    • /
    • 2016
  • The columnar joints in Goheung are developed in three places of Yuju-san area, Palyeong-san and Yongbawi area. Vertical and fan-shaped columnar joints which have maximum width 100 m and maximum heigh 50 m are developed in the Yuju-san area Columnar joints are developed next to the road near the the Yuju-san and along the coast of Jijuk-do. Thick columnar joints of maximum width 1m are developed in the Paryeong-san area. Horizontal columnar joints of maximum width 50 cm at length of polygon side are developed on dyke in the Yongbawi area. The columnar joints show high rate of rectangles and pentagons in the number of polygons. The length of polygon side of columnar joints in study area ranges from 10 to 100 cm, and 20 cm among the range appears in high frequency. Columnar joints are developed vertically to the ground from the cooling surface in Yuju-san and Palyeong-san area. Columnar joints in Yongbawi area are developed vertically to the contact of country rocks. As a result, the columnar joints began cooling from the country rock contact. And columnar joints are developed vertically to contact surface. The rocks in columnar joints is rhyolitic welded tuff in Yuju-san and Palyeong-san area, dacite in Yongbawi area. In the acid volcanic rocks flow structure well developed. The white phenocryst mineral about 2 mm size by eye, is usually feldspar, and includes some quartz. The rate of $SiO_2$ is 70wt.% or more. It is the last stage of differentiation to calc-alkaline series. The columnar joints of the Yuju-san area are expected to be distributed along a band that extends to about 1km east of the stone pit.

The Cytotoxicity and Effect on the Experimental Rabbit Cornea of Soft Contact Lens Multi-Purpose Solution (MPS) (콘택트렌즈용 다목적용액(MPS)의 세포증식저해 및 실험용 토끼 각막에 미치는 영향)

  • Koh, Eun-Gyeong;Chae, Soo-Chul;Park, Su-Kyoung;Kim, Deok-Song;Lee, Jong-Bin
    • Applied Microscopy
    • /
    • v.36 no.3
    • /
    • pp.141-153
    • /
    • 2006
  • The purpose of this study is to find out how soft contact lens multi-purpose solution (MPS), often used for medical treatment, effects the inhibition on cell growth and research the result of using MPS, suspected to demage eye cells, on rabbit eye's corneal epithelium and endothelium tissue. In this treatise, $ReNu^{(R)}$ (Baush & Lomb, USA), Opti-free $express^{(R)}$ (Alcon, USA), Free-sol $plus^{(R)}$ (Hanamedicon, Korea) had been selected among the MPS. After culturing L929 roil line, cell growth inhibition rate was measured by MTT assay, and by making Hematoxylin and Eosin stain specimen. the morphology was observed by optical microscope. In the In vivo experiment,9 white rabbit eyes (18 eyes) were classified into 3 groups. The experimental group is left eyes (9 eyes) of rabbit, and MPS were dropped; however. the control group, the right eyes (9 eyes), were only used a saline solution without preservatives. After the dropping within the period, the cornea surface of rabbit eyes were stained by Rose bengal and observed. To figure out the changes of the corneal epithelium and endothelium tissue scanning electron microscopy (SEM) has been used. As the result, the rate of cell growth inhibition was 54%. 73% and 36%, respectively. Morphological changes represented that the shape has been changed into oval or round shape and those are not considered as a common formation of L929 cell line. When it comes to staining Rose bengal, each experiment group was stained red which is not shown in controls. The polygonal mosaic pattern of a corneal epithelium was disturbed in the picture taken by SEM; furthermore, the shape of the corneal endothelium was irregular. In conclusion, as we consider antimicrobial effect and the safety on living cells, it is necessary that we should improve concentration of preservatives and study continuously to develop a new preservatives without a toxic effect on the cornea surface.

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.