• 제목/요약/키워드: Eye contact

Search Result 211, Processing Time 0.025 seconds

A Study on the Use of IoT in Infant Care (영아 돌봄에서 IoT 활용에 대한 일고찰)

  • Yee, YoungHwan;Hwang, Sheenhai
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.4
    • /
    • pp.59-66
    • /
    • 2017
  • These days, IoT attached diaper are available in markets. It measures child's temperature, oxygen rate, or even humidity of diaper and send the result directly to parent's smartphone. This research emphasize the followings, due to the fact that use of IoT in context of infant care should ultimately be leaded to infant's wellbeing and healthy development. First, there can be many problems when you only focus on usability without careful consideration of the accuracy of the infant's health information produced by the IoT. Second, infant's needs and nature of child should be reflected when developing IoT which supports infant care. The use of the IoT should not take away the chance of physical contact such as eye-contact or patting and hugging between the caregiver and baby. IoT is very important, however in terms of infant development, connect with IoT cannot antecede contact with child.

Study on the Antibiosis and Physical Properties of Copolymer Containing Silver (은을 포함한 공중합체의 항균성 및 물리적 특성에 관한 연구)

  • Ye, Ki-Hun;Cho, Su-Hyeon;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.5
    • /
    • pp.542-546
    • /
    • 2009
  • Recently, silver has been applied to various fields due to antimicrobial property and high conductivity. We manufactured high-performance ophthalmic material containing silver which could protect eye from environmental factors. We mixed $AgNO_3$ with conventional contact lens material. And then we copolymerized at 70 ${^{\circ}C}$ for 40 minutes under water bath, and estimated antimicrobial activity and physical properties. We used solid culture and liquid culture medium for antimicrobial test. The results of contact lens containing silver showed good antibiosis. In case of physical properties, the results showed 32.35%(water content) and 88.34% (visible transmittance) for each. We judged that we made the copolymer with antimicrobial and physical properties which is suitable for conventional contact lens.

Non-contact Input Method based on Face Recognition and Pyautogui Mouse Control (얼굴 인식과 Pyautogui 마우스 제어 기반의 비접촉식 입력 기법)

  • Park, Sung-jin;Shin, Ye-eun;Lee, Byung-joon;Oh, Ha-young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.9
    • /
    • pp.1279-1292
    • /
    • 2022
  • This study proposes a non-contact input method based on face recognition and Pyautogui mouse control as a system that can help users who have difficulty using input devices such as conventional mouse due to physical discomfort. This study includes features that help web surfing more conveniently, especially screen zoom, scroll function, and also solves the problem of eye fatigue, which has been suggested as a limitation in existing non-contact input systems. In addition, various set values can be adjusted in consideration of individual physical differences and Internet usage habits. Furthermore, no high-performance CPU or GPU environment is required, and no separate tracker devices or high-performance cameras are required. Through these studies, we intended to contribute to the realization of barrier-free access by increasing the web accessibility of the disabled and the elderly who find it difficult to use web content.

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

Human rhinoviruses and asthma in children

  • Kim, Woo Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.2
    • /
    • pp.129-135
    • /
    • 2010
  • Human rhinoviruses (HRVs) is a nonenveloped, single stranded RNA virus belonging to the family Picornavirudae. Transmission by direct contact such as hand-to-hand, hand-to-nose, and hand-to-eye has been readily demonstrated in experimental settings. HRV are the most frequent causes of common cold infection, however, they are also known to replicate in the lower respiratory tract and associated with more severe respiratory illnesses such as asthma. New technique such as reverse transcriptase polymerase chain reaction and molecular typing in HRV has been developed and our understanding of the importance of these respiratory viruses. HRVs consisted of 101 serotypes that are classified into groups A and B according to sequence variations. And there is a newly identified set of HRVs, called Group C, and it is currently under investigation. In recent study using PCR techniques, HRVs accounted for approximate 50-80% of common colds and 85 % of childhood asthma exacerbations and in more than half of adult exacerbations. However, the mechanisms of HRV- induced asthma exacerbations are poorly understood. This review discusses the association between HRVs and childhood asthma.

Nature as a Model for Mimicking and Inspiration of New Technologies

  • Bar-Cohen, Yoseph
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Over 3.8 billion years, through evolution nature came up with many effective continually improving solutions to its challenges. Humans have always been inspired by nature capabilities in problems solving and innovation. These efforts have been intensified in recent years where systematic studies are being made towards better understanding and applying more sophisticated capabilities in this field that is increasingly being titled biomimetics. The ultimate challenge to this field is the development of humanlike robots that talk, interpret speech, walk, as well as make eye-contact and facial expressions with some capabilities that are exceeding the original model from nature. This includes flight where there is no creature that is as large, can fly as high, carry so heavy weight, fly so fast, and able to operate in extreme conditions as the aircraft and other aerospace systems. However, there are many capabilities of biological systems that are not feasible to mimic using the available technology. In this paper, the state-of-the-art of some of the developed biomimetic capabilities, potentials and challenges will be reviewed.

Non-contact Eye Gaze Point Estimation System by Mapping of Corneal Reflections (각막 반사의 매핑을 이용한 비접촉식 눈의 응시점 추정 시스템)

  • Yoo, Dong-Hyun;Chung, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2352-2354
    • /
    • 2001
  • 본 논문에서는 컴퓨터의 사용자가 모니터의 스크린 상의 어느 곳을 바라보고 있는지 추정하는 새로운 알고리즘을 제시한다. 적외선 LED와 CCD카메라를 이용하는 이 방법은 기존의 방법과 다르게 5개의 적외선 LED를 사용하는데 적외선의 반사에 의해 눈의 각막에는 네 개의 밝은 점들이 나타나고 이 점을 꼭지점으로 하는 사각형 안에서 동공의 중심이 움직인다는 사실을 이용한다. 이 방법은 눈의 3차원 위치, 카메라의 위치, 모니터의 위치에 따른 관계식을 구할 필요 없이 간단한 계산으로 눈의 응시점을 찾아낼 수 있다는 장점을 가지고 있다. 여기서는 이 방법을 소개하고 실험결과를 보여준다.

  • PDF

Changes in Dogs' Social Behavior Toward Humans

  • Kang, Ok-Deuk
    • Journal of Environmental Science International
    • /
    • v.31 no.3
    • /
    • pp.237-245
    • /
    • 2022
  • The purpose of this study is to evaluate dogs' sociality toward human strangers in the absence of an owner by analyzing changes in dogs' behavior during a task of making eye contact with an experimenter to obtain snacks. A total of 17 dogs were divided into groups of high sociality (HS; n = 10, 4.4 ± 3.87 years) and low-sociality (LS; n = 7, 3.71 ± 2.06 years). A comparison of the average frequency of five behavioral types-fear-appeasement behaviors (P<0.001), sociability-related behaviors (P<0.001), stress-related behaviors (P<0.05), destruction (P < 0.001), and vocalization (P < 0.001)-between the groups showed a significant difference in all five categories. Together, these results suggest that dogs with high sociality are less exposed to various stresses and have a higher ability to adapt to new environments than dogs with low sociality. This can predict dogs' adaptability to a new environment and positive outcomes in their daily life with the owner.

A Study on Prescription of RGP Contact Lens in Korean Optometrist (안경사의 RGP콘택트렌즈 처방 실태조사)

  • Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.7-17
    • /
    • 2007
  • There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.

  • PDF