• Title/Summary/Keyword: Eye condition

Search Result 323, Processing Time 0.037 seconds

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

An analysis of factors affecting aspects of disease and satisfied medical treatments for oriental medical users (한방의료(韓方醫療) 이용자의 질병양상(疾病樣相)과 치료만족도(治療滿足度)에 영향(影響)을 미치는 요인분석(要因分析))

  • An Chang-Su;Nam Chul-Hyun
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.3 no.2
    • /
    • pp.101-128
    • /
    • 1999
  • A study on disease treated at oriental medical treatment facilities (OMTF) and patients' satisfaction levels was conducted in order to figure out why the patients visited oriental medical doctors and the level of satisfaction of the patients for the services offered to them by oriental medical doctors. This study was performed from March 2 through May 31, 1998 by interviewing 1.532 persons living in major and small cities in korea. The results obtained were summarized as follows; 1. The general characteristics of subjects. The highest portion of each part was, 66.9% female, persons in the age group of over 60's 22.7%, high school graduated 34.9%, house wife 30.8%, The married 65.0%, Buddhist 36.9%, maj or city residents 60.2%, company covered insurance benefiter 39.0% and etc. 2. 40.5% of subjects visited OMTF for skeletal and connective tissue diseases. 21.5% for digestive system diseases. 16.2% for respiratory system diseases. 13.3% for circulatory system diseases and 9.0% for neurological problems. 3. 42.7% of males visited OMTF for skeletal and connective tissue diseases, which were the highest and respiratory system disorders, digestive system disorders, circulatory system disorders and neurological diseases in order. 39.4% of females visited OMTF for skeletal and connective tissue disorders which were the highest and other conditions such as digestive system, circulatory, respiratory, and neurological disorders in order. 4. The males with circulatory system disorders were treated by herbal medicine, combination of herbal medicine and acupuncture, only in order. The females with the some conditions above were treated by combination of herbal medicine and herbal medical and acupuncture only in order. The males and females with respiratory system and digestive system diseases were treated by herbal medicine, combination of herbal medicine and acupuncture only in order. But the males and females with skeletal and connective tissue diseases were by acupuncture are the highest in order. 5. The females and persons in the age group of over 60' s and house wife. the not married, the unhealthy persons, residents living in small cities, the persons with high income by medical treatments frequency in circulatory system diseases are the highest. 6, The females, middle school graduated and the married, persons in the age group of over 60's, unemployed, sales and service industry workers, Buddhists, major city residents, the unhealthy persons, the persons with middle income by medical treatments frequency in respiratory system diseases are the highest. 7. The females, persons in the age group of over 60's, under graduated or elementary school graduated, the unemployed and house wife, the unmarried, Buddhists, major city residents, the unhealthy persons, the persons with low income by medical treatments frequency in digestive system diseases are the highest. 8. The males, major city residents, old ages, under graduated or elementary school graduated, go earn officials, people grown in small city, the persons who had health insurance policies, the persons with low income, the unhealthy persons by medical treatments frequency in skeletal and connective tissue disorders diseases. 9. 50.8% of the respondents said that the treatments at the OMTF were very effective. 47.7% of them said that the treatments were effective. The males, persons in the age group of 40's, high school graduates, official workes, the married, the persons who did not have religion, major city residents, the persons who had health insurance policies, the persons with high income and the healthy persons said that the treatment effects at OMTF were satisfactory. 10. The patients' satisfaction rate for OMTF on each disease is, 1st. Musculo-Skeletal system(most satisfied), 2nd. the pregnancy & delivery complications, 3rd. Eye & ophthalmics, 4th. Respiratory system, 5th. Mental & bodily disorder, 6th. Digestive system and etc. 11. The factors affect OMTF are age, satisfaction for OMTF, current disease, religion, efficiency of Oriental Medicine, health condition and etc. This explained power of variable were 39.0%. 12. The satisfied factors for OMTF is correlate to educational level, and economical variables.

  • PDF

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.

Comparison and Correlation between Distance Static Stereoacuity and Dynamic Stereoacuity (원거리 정적 입체시와 동적 입체시의 평가 및 상관관계)

  • Kim, Young-Cheong;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.385-390
    • /
    • 2015
  • Purpose: This study evaluated the static stereoacuity by Distance Randot Stereotest (STEREO OPTICAL. Co., Inc. USA) and the dynamic stereoacuity by three-rods test (iNT, Korea). Criterion and correlation of stereoacuity between both tests and usefulness of two stereotest methods were also evaluated. Methods: For normal adults of 109 (male 61, female 48), mean age of 20.88 (19-32 years) years old, static stereoacuity by using Distance Randot Stereotest at 3 m distance, dynamic stereoacuity by using three-rods test at 2.5 m distance were measured. Results: The mean of distance static stereoacuity was $155.77{\pm}133.11sec$ of arc and the mean of error distance dynamic stereoacuity $11.13{\pm}9.69mm$. With equivalent-conversion stereoacuity of $23.44{\pm}20.96sec$ of arc, there was statistically significant differences (p=0.00) between two dynamic stereoacuity, but correlation was relatively low (${\rho}=0.226$). In the case of dynamic stereoacuity, separated to normal range by criterion of the error distance 20 mm, it showed the error distance of less than 20 mm in 97 subjects(89%) whose average of error distance and conversion mean dynamic stereoacuity were $8.43{\pm}5.10mm$ and $17.68{\pm}10.67sec$ of arc. repectively. The error distance of was equivalent-conversion dynamic stereoacuity 40.99 sec of arc (PD 62 mm basis) was 20 mm. Conclusions: The results of lower correlation between static and dynamic stereoacuity suggest that seterotest should be applied separately to different functions. The results of this study also suggest that Distance Randot Stereotest can be applied to static stereoacuity excluding monocular cues. Three-rods test can be applied to dynamic stereoacuity containing the response of the eye-hand coordination in the daily life of natural vision condition, including the monocular cues. These different approaches canprovide a criterion of the two stereoacuity and parallel use of the two tests would be useful. For dynamic stereoacuity by three-rods test, error distance 20 mm in a normal range of adults can be used as a criteria to get statistical meaning of the results.

The Design and Evaluation of a Diagonally Splitted Column to Improve Text Readability on a Small Screen (소형 스크린 상에서의 텍스트 가독성 향상을 위한 대각분할 칼럼 디자인과 평가)

  • Kim Yeon-Ji;Lee Woo-Hun
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.51-60
    • /
    • 2006
  • Nowadays, reading text from screens is prevailing in everyday life. The advent of mobile information devices such as a cellular phone, PDA, and e-book reader facilitates us to enjoy various text-based contents any time and anywhere. Most studies comparing screen and paper readability show that screens are less readable than paper. Furthermore, the decrease of line length and number of lines that can be displayed on the screen of mobile information devices deteriorate text readability. This study investigated parameters affecting text readability on small screens and designed a new text layout to improve readability. We suggested a diagonally splitted layout of rectangular column, which is supposed to facilitate eye movement to trace text flow with ease. The experiment comparing readability between a traditional rectangular column and a diagonally splitted column was conducted. The result of experiment revealed that there is no significant difference between the two text layouts in terms of subjective satisfaction of reading task and a level of comprehension. However, in the screen size of $4000mm^2\;and\;8000mm^2$, reading speed was increased 18.9% and 34.0% respectively from a traditional rectangular column to a diagonally splitted column. We conducted a consecutive experiment to scrutinize the cause that improved the performance in readability task remarkably. The readability of text in a traditional rectangular column was compared with a left triangular column and a right triangular column in the condition of $4000mm^2/3:1$ ratio screen. The performance measurements revealed that participants read 21.1% and 67.6% faster respectively with the left triangular column and right triangular column than with the rectangular column. In consequence, the improvement of readability in the diagonally splitted column was attributed mainly to the increase of reading speed in the right triangular column. This research verified that the diagonally splitted column improve text readability on a small screen and this result is expected to make a contribution to designing an efficient text layout for mobile information devices

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Changes of Lens Morphology and TBUT by Dehydration of Soft Contact Lens (소프트콘택트렌즈 건조로 인한 렌즈 형태 및 TBUT의 변화)

  • Park, Mijung;Lee, Yu-Na;Kang, Kyu Eun;Lee, Min Ha
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose: This study was performed to evaluate the changes of lens morphology and tear stability during wearing soft contact lenses (SCLs) which were kept in drying condition like dry eye or became to be dried due to heedless care. Method: SCLs having different water content, thickness or material were rehydrated after being dehydrated artificially 2 or 4 times, and estimated their diameter and radius. Furthermore, the changes of tear film break-up time (TBUT) during SCL wearing were also measured. Result: Due to the dryness, the diameter of both 70% water content SCL and 59% water content SCL decreased, but the decrement was larger in 59% water content SCL. The more 59% water content SCL was dehydrated, the more its radius changed. However, the radius of 70% water content SCL did not change by 2 times dehydration and increased greatly by 4 times dehydration. The reduction of diameter of -1.00 D SCL was greater than that of -9.00 D SCL. Moreover, the radius of -1.00 D SCL increased depending on the frequency of dehydration but that of -9.00 D SCL did not changed. The diameter and radius changes of lotrafilcon B, silicone hydrogel lens, were less than those of hilafilcon B, copolymer of HEMA and N-vinyl pyrrolidone. TBUT during wearing SCLs decreased by wearing dehydrated SCLs. Conclusion: The diameter and radius of dehydrated SCLs as well as TBUT during wearing them were changed in spite of rehydration, which would be the important cause of uncomfortable feeling when people wore dehydrated SCL. The changes of SCL morphology and TBUT differed according to the water content, lens thickness and material.

  • PDF

The Prevalence and Characteristics of Positional Obstructive Sleep Apnea

  • Kim, Cheon-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Lee, Sang-Ahm
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.52-58
    • /
    • 2012
  • Patients with obstructive sleep apnea (OSA) often have more aggravated symptoms in the supine position. We tried to investigate the clinical characteristics and the predictive factors for positional OSA. Polysomnographic data were reviewed for OSA patients (apnea hypopnea index, $AHI{\geq}5$) from April, 2008 to April, 2011 at the Asan Medical Center. Clinical data, comorbid medical condition data and questionnaires (SF-36, MFI-20, ESS, BDI, STAI) were assessed. All patients were classified into two groups: positional patients (PP) group and non-positional patients (NPP) group. PP was defined as a patient who had the AHI in the supine position was at least twice as high as that in the lateral position. The body position of patients was confirmed by sleep position sensor and video monitor. All patients had at least 30 minutes of positional and 30 minutes of non-positional sleep. We compared clinical, medical, polysomnographic data, and questionnaire results between two (PP and NPP) groups and investigated predictive factors for the PP group using binary logistic regression analysis. In total, 371 patients were investigated. 265 (71.4%) was categorized as PP group and 106 (28.5%) as NPP group. The mean age ($mean{\pm}SD$) was higher in the PP group ($52.4{\pm}9.8$) than in the NPP group ($49.5{\pm}11.9$) (p<0.05). Comparison of sleep parameters between the PP and the NPP group showed that the PP group had significantly lower BMI (PP: $26.1{\pm}3.2kg/m^2$; NPP: $27.8{\pm}4.3kg/m^2$, p<0.001), neck circumference (PP: $39.7{\pm}2.8cm$; NPP: $41.5{\pm}3.7cm$, p<0.001) and hypertension rate (PP: n=89/265 (33.5%); NPP: n=48/106 (45.2%), p=0.0240). In the PP group, the percentage of deep sleep (PP: $8.7{\pm}8.1%$; NPP: $5.6{\pm}7.0%$, P=0.001) and rapid eye movement (REM) (PP: $17.5{\pm}6.1%$; NPP: $14.0{\pm}6.9%$, p<0.001) were significantly higher whereas the percentage of light sleep (stage N1) was significantly lower than the NPP group (PP: $30.4{\pm}12.3$; NPP: $44.5{\pm}20.8%$, p<0.001). During the sleep, the AHI in the supine position (PP: $48.6{\pm}19.5$; NPP: $60.5{\pm}22.6$, p<0.001) and in the non-supine position (PP: $9.4{\pm}8.9$; NPP: $48.4{\pm}24.8$, p=<0.001) were significantly lower and the minimal arterial oxygen saturation in non-REM sleep was significantly higher in the PP group (PP: $80.3{\pm}7.6$; NPP: $75.1{\pm}9.9$, p=<0.001). There were no significant differences in all questionnaires including quality of life. The results of the binary logistic regression analysis showed that age, the amount of REM sleep(%) and AHI were significant predictive factors for positional OSA. The significant predictive factors for positional OSA were older age, higher percentage of REM and lower AHI. The questionnaire results were not significantly different between the two groups.

  • PDF

The Affirmation and Redemption of Life and Übermensch in Nietzsche's Thought (니체에게서 삶의 긍정 및 구원Erlösung과 위버멘쉬Übermensch)

  • Kim, Joo-whee
    • Journal of Korean Philosophical Society
    • /
    • v.131
    • /
    • pp.77-103
    • /
    • 2014
  • It is well known that Nietzsche insists on the affirmation of life, and the subject of 'affirmation of life' is a familiar one in Nietzsche literature. We want to throw an unfamiliar light on this familiar subject, connecting the theme of affirmation with that of redemption, and insisting on the centrality of the theme of redemption in Zarathustra's teaching of ${\ddot{U}}bermensch$. For Nietzsche, the redemption of human life means that its life is endowed with some meaning and its existence is positively justified. With this redemption, an active affirmation of life is possible, which means that we not only endure this life once but also request it for indefinite times. According to Nietzsche, for this kind of redemption and active affirmation we need an ultimate ground of meaning and only the excellence of life, that is, of 'will to power' can serve as this ultimate ground. Accepting the Greek way of identifying virtue with excellence, Nietzsche thought that life can justify itself at the ultimate form of life in ${\ddot{U}}bermensch$. Then, through ${\ddot{U}}bermensch$ the way is opened for man to endow meanings on and justify its life. That is, ${\ddot{U}}bermensch$ is not only the one who affirms its life, but also the very condition in which humanity can justify its life in general. With the goal and ideal of ${\ddot{U}}bermensch$ accepted, the affirmation and redemption of an individual life depends on how it manages to create its own life in relation to this goal and ideal. According to Nietzsche, though we cannot go back to the past, we still can recreate it and change its meanings through working on the future. Only those who try to create a meaningful future and thus recreate the past could redeem and affirm their own lives. That is, for Nietzsche, to affirm and redeem one's life means not just to change one's attitude to life but to create and recreate it with the eye for ${\ddot{U}}bermensch$.

On the present bamboo groves of Cholla-nam-do and their proper treatment -No. 1. On the growing stock of reprsentative phyllostachys reticulata grove by county (전라남도(全羅南道)의 죽림현황(竹林現況)과 그 개선대책(改善對策) -제일(第一), 각군별대표고죽림(各郡別代表苦竹林)의 몇가지 죽간형질(竹桿形質)과 축적(蓄積)에 대하여)

  • Chung, Dong Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.2 no.1
    • /
    • pp.19-28
    • /
    • 1962
  • Total area of bamboo groves in Korea which is limited to $37^{\circ}$ north latitude, i.e., to southern part of Chungchung-nam-do Province and Kangwon-do Province, is 3,235ha., but this country must import about 3,000 metric ton's bamboo culms from Japan every year. It may be true that the country is not so fit for economical cultivation of bamboo groves from the view point of climatic condition, but the author believes that self-sufficiency in bamboo is not impossible if some scientific method for improving bamboo groves is introduced to our primitive groves. Keeping this point in his mind the auther tried to study on the bamboo groves in the country, and as the first step set about to investigate the actual state of twenty good bamboo groves located in Cholla-nam-do Province from March, 1961 to January, 1962. This is a report on some characters of bamboo culms and growing stock with samples collected in the present investigation. 1) Numbers of bamboo culm per 0.1ha. are 1,183 in average, 1,840 in maximum and 87.5 in minimum before harvesting. 2) According to owners' saying, 1960 was such an off-year that they could hardly see any yearling bamboos in groves, but in 1961 very many new bamboos are produced as follows: the proportion of the number of yearling bamboos produced this year to that of mature bamboos (over 2 years old) is 58.7% in average; the highest 110.5% and the lowest 16.8%. 3) the average diameter of culms at eye height is 6.5cm, but the biggest diameter comes to 11.2 cm, and the average diameters of yearling and mature bamboos are 6.5cm and 6.6cm respectively. 4) Internode length records 29.4 cm in average, the shortest 21.3 cm and the longest 38.4 cm. Average internode lengths of new culms and mature culms are 27.6 cm and 29.4 cm respectively. This shows that the internode length of new culms is in the decrease to that of maturer's. 5) Through this investigation, it was found that internode length is in the influence of the exposure and density of bamboo groves, i. e., the more the dencity of bamboo groves is and the more the exposure nears the north-east, the longer the internode length becomes (see Table 7 and 8). 6) In the growing stock of bamboo groves, bundles per 0.1ha. amount to 271 sok (unit of bundle) in total average, 445 sok in maximum and 126 sok in minimum. 7) Among twenty typical bamboo groves, chosen in each County in Cholla-nam-do Province, only one passes perfectly by Veda's standard rule* prescribing the good bamboo grove, but the eight groves shown in Table 9 could be recommended as good ones in Cholla-nam-do Province, because the auther believes that those groves may be improved better, if we pay more attention to the management of them. 8) Considering that they have managed their groves carelessly and primitively, and that unfortunately their groves must have faced almost on clear felling over the entire area at the time of the Korean War, we can surely expect much more increments in bamboo groves, if we introduce some scientific methods in managing their groves.

  • PDF