• Title/Summary/Keyword: Eye Contact

Search Result 211, Processing Time 0.024 seconds

Real-time Eye Contact System Using a Kinect Depth Camera for Realistic Telepresence (Kinect 깊이 카메라를 이용한 실감 원격 영상회의의 시선 맞춤 시스템)

  • Lee, Sang-Beom;Ho, Yo-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.277-282
    • /
    • 2012
  • In this paper, we present a real-time eye contact system for realistic telepresence using a Kinect depth camera. In order to generate the eye contact image, we capture a pair of color and depth video. Then, the foreground single user is separated from the background. Since the raw depth data includes several types of noises, we perform a joint bilateral filtering method. We apply the discontinuity-adaptive depth filter to the filtered depth map to reduce the disocclusion area. From the color image and the preprocessed depth map, we construct a user mesh model at the virtual viewpoint. The entire system is implemented through GPU-based parallel programming for real-time processing. Experimental results have shown that the proposed eye contact system is efficient in realizing eye contact, providing the realistic telepresence.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Technology Development for Non-Contact Interface of Multi-Region Classifier based on Context-Aware (상황 인식 기반 다중 영역 분류기 비접촉 인터페이스기술 개발)

  • Jin, Songguo;Rhee, Phill-Kyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.175-182
    • /
    • 2020
  • The non-contact eye tracking is a nonintrusive human-computer interface providing hands-free communications for people with severe disabilities. Recently. it is expected to do an important role in non-contact systems due to the recent coronavirus COVID-19, etc. This paper proposes a novel approach for an eye mouse using an eye tracking method based on a context-aware based AdaBoost multi-region classifier and ASSL algorithm. The conventional AdaBoost algorithm, however, cannot provide sufficiently reliable performance in face tracking for eye cursor pointing estimation, because it cannot take advantage of the spatial context relations among facial features. Therefore, we propose the eye-region context based AdaBoost multiple classifier for the efficient non-contact gaze tracking and mouse implementation. The proposed method detects, tracks, and aggregates various eye features to evaluate the gaze and adjusts active and semi-supervised learning based on the on-screen cursor. The proposed system has been successfully employed in eye location, and it can also be used to detect and track eye features. This system controls the computer cursor along the user's gaze and it was postprocessing by applying Gaussian modeling to prevent shaking during the real-time tracking using Kalman filter. In this system, target objects were randomly generated and the eye tracking performance was analyzed according to the Fits law in real time. It is expected that the utilization of non-contact interfaces.

The status of care for Soft Contact Lens and periodic examination (연성 콘택트렌즈의 관리 및 정기검사 실태)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • This study has analyzed soft contact lens care-after-sale and periodic examinations at optical shops and eye clinics. And I wish to make that use of educational data for the soft contact lens lesson of the department of ocular optics. This questionnaire studied the status of care for soft contact lens and periodic examination, of students who wears soft contact lens. The results are as follows: First, 7.5% of students questioned wore soft contact lens. More women than men wore soft contact lens. The soft contact lens wearers purchased lens mainly at optical shops. 78.5% of them wore daily wear lens. Because of cosmetic advantages of soft contact lens. 47.9% of them wore soft contact lens. 72.5% of them wore soft contact lens less than 12 hours per a day. 32.0% of them has worn soft contact lens more than 6 months less than 1 year. 51.1% of them experienced irritation. 39.7% of them have exchanged soft contact lens between 6 and 9 months. Secondly, when purchasing lenses. 60% of soft contact lens wearers were given instructions of general care, such as duration of wearing lens, how to remove protein, how to store, and how to sterilize at both of eye clinics and optical shops. But the proportion of instructions, such as side effects and periodic examination which were given to soft contact lens wearers, is lower both at eye clinics and optical shops. Especially at optical shops, the proportion of instruction for periodic examination, is lower than at eye clinics(p<0.05). Thirdly, The proportion of operations of periodic examinations after use of soft contact lens both at eye clinics and optical shops, is low. The soft contact lens wearers have had more periodic examinations at eye clinics than at optical shops. But the rate of non-periodic examination at optical shop is 87.9%. And for periodic examinations, general care was done at optical shops. On the other hand, eye examinations, general care, and treatments were done more at eye clinics. Fourthly, 60.3% of the soft contact lens wearers understood the necessity of the periodic examinations, but actually, only 6.4% of them were given the schedule for the periodic examinations, and 2.5% of them were given at an optical shop(p<0.01).

  • PDF

MONJUnoCHIE SYSTEM : VIDEOCONFERENCE SYSTEM WITH EYE CONTACT FOR DECISION MAKING

  • Terumasa Aoki;Kustarto Widoyo;Nobuki Sakamoto
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.177-182
    • /
    • 1999
  • With the recent evolutionary progress in network and terminal technologies, current videoconference systems are in the level of practical use. The existing systems, however, would not be fully useful for decision making process since eyes of users can not always be in contact that makes it difficult to read the expression of participants. In this paper, we discuss the principle and the impact of“MONJUnoCHIE System”a videoconference system with eye contact using a special display device called“Glass Vision”.

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

The stability of tear film for Korean (한국인에 대한 누액 안정성 조사)

  • Lee, Seong-Wook;Sim, Hyun-Seog;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.161-164
    • /
    • 2001
  • The purpose of our study was stability of tear film for Korean. In the 1970s, the major problem for the contact lens practitioner was the management of contact lens parameters. In the 1980s, oxygen permeability was the main problem in contact lens practice: now it is dry eyes. To appropriately fit the patient with contact lenses it is imperative to know in advance if the patient has a marginal dry eye. Based on the initial diagnosis appropriate care can be taken to minimize problems with the result that the patient can successfully wear contact lenses. A well known test for dry eyes is Schirmer test which has shown to be useful for diagnosing Sjogren syndrome. Biomicroscopy can often unmask numerous problems. The classical test for marginal dry eye is measuring the tear break up time(TBUT). A dry eye problem with contact lenses is often caused by the lid. If an incomplete blink is responsible for the dry eye it is possible to change the situation by blinking exercises. The result of these test, mean value of age was 22.8, mean value of blink rate was 19 times/min, mean value of Schirmer test was 25 mm/5 min, mean value of TBUT was 7.1 sec.

  • PDF

The Study of the Corneal Diopter Power and Corneal Radius on the Contact Lens Wear of the Korean Female in the Twenties Age (20대 한국여성의 콘택트 렌즈 착용자에 대한 각막 굴절력과 곡률반경에 대한 연구)

  • Kim, Douk-Hoon;Hwang, Sun-Hyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.127-131
    • /
    • 1997
  • An analysis on the corneal diopter power and corneal radius has been carried out the Korean female in the twenties age. The results were as follows. The most contact lens wears have the early stage of the twenties age, but the increase of aging have a decrease. The mean corneal diopter power on the right eye have 44.04 diopter, but left eye have 43.92 diopter. The mean of corneal radius on the right eye have the 7.66 mm, but left eye have the 7.69 mm. As a results, In increasing of the age, Most mean corneal diopter power have increase, but the mean of corneal radius have not change.

  • PDF

The adsorption pattern of protein to the soft contact lens and its effect on the visible light transmission and the contact angle (소프트콘택트렌즈의 단백질 부착 양상 및 가시광선투과도와 접촉각에 미치는 영향)

  • Park, Mijung;Kwon, Mi Jeong;Lee, Sun Hee;Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.53-68
    • /
    • 2004
  • Protein deposit buildup on soft contact lenses(SCLs) is responsible for discomfort, optical defects and is even damaging to the eye. To better understand protein deposit formation on SCL, we investigated the pattern of protein attachment on patient-worn SCLs and the effect of the protein on the contact angle of SCLs and the transmission of visible light. This study used data from a clinical trial where subjects wore either daily-wear SCL(etafilcon A, N=40) for various period up to 14 days, or extended-wear SCL(balafilcon A, N=40) for 8 h day or night. The adsorption of protein in daily-wear SCLs was significantly increased in patient-worn time-dependent manner although the lenses were cleaned everyday by using the multi-purpose SCL solution. After 2 weeks wearing, the protein on the SCL influenced the contact angle of the lenses. Furthermore, the transmission of visible light of the lenses decreased up to almost 7%. Extended-wear SCLs worn during the closed eye condition were found to deposit significantly more protein than SCLs worn during the open eye condition. The amounts of protein adsorbed both after daily SCL wear and after overnight SCL wear were not affected the contact angle and the transmission of visible light of the lenses. The protein deposit buildup on SCL related to the corneal temperature and pH of tear fluid.

  • PDF

Comparison of Induced Aniseikonia with Influential Factors (영향인자에 따른 유발 부등상시도의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.45-51
    • /
    • 2013
  • Purpose: This study was performed to provide indicator of expected aniseikonia by correcting refractive error and to investigate influential factors on aniseikonia. Methods: 20 college students (14 males, 6 females, a mean age of $22.50{\pm}2.72$ years) were selected as subjects whose refractive error with spherical equivalent were within ${\pm}0.50$ D, corrected visual acuity were more than 1.0, and aniseikonia values by AWAYA were less than 1%. After correcting refractive error with spectacles in anisometropia induced by wearing contact lens on their dominant eye or non-dominant eye, practical measured values of aniseikonia were compared with theoretical expected values of it by the formula of spectacle magnification. Results: Practical measured values were higher than theoretical expected values in induced aniseikonia over the whole range of diopter of wearing contact lens. And there was higher measured value of aniseikonia in case of higher diopter of wearing contact lens to induce anisometropia and correcting refractive error with spectacles of (+) diopter after wearing contact lens of (-) diopter to induced anisometropia in dominant eye of women. Conclusions: It is considered that dominant eye plays more important role for visual function in induced aniseikonia and factors such as the induced eye of aniseikonia, the diopter of wearing contact lens, and gender have influenced on aniseikonia.