• 제목/요약/키워드: Extreme-Pressure

검색결과 314건 처리시간 0.022초

Estimation of extreme wind pressure coefficient in a zone by multivariate extreme value theory

  • Yang, Qingshan;Li, Danyu;Hui, Yi;Law, Siu-Seong
    • Wind and Structures
    • /
    • 제31권3호
    • /
    • pp.197-207
    • /
    • 2020
  • Knowledge on the design value of extreme wind pressure coefficients (EWPC) of a specific zone of buildings is essential for the wind-resistant capacity of claddings. This paper presents a method to estimate the representative EWPC introducing the multivariate extreme value model. The spatial correlations of the extreme wind pressures at different locations can be consider through the multivariate extreme value. The moving average method is also adopted in this method, so that the measured point pressure can be converted to wind pressure of an area. The proposed method is applied to wind tunnel test results of a large flat roof building. Comparison with existing methods shows that it can give a good estimation for all target zones with different sizes.

Improved first-order method for estimating extreme wind pressure considering directionality for non-typhoon climates

  • Wang, Jingcheng;Quan, Yong;Gu, Ming
    • Wind and Structures
    • /
    • 제31권5호
    • /
    • pp.473-482
    • /
    • 2020
  • The first-order method for estimating the extreme wind pressure on building envelopes with consideration of the directionality of wind speed and wind pressure is improved to enhance its computational efficiency. In this improved method, the result is obtained directly from the empirical distribution of a random selection of annual maximum wind pressure samples generated by a Monte Carlo method, rather than from the previously utilized extreme wind pressure probability distribution. A discussion of the relationship between the first- and full-order methods indicates that when extreme wind pressures in a non-typhoon climate with a high return period are estimated with consideration of directionality, using the relatively simple first-order method instead of the computationally intensive full-order method is reasonable. The validation of this reasonableness is equivalent to validating two assumptions to improve its computational efficiency: 1) The result obtained by the full-order method is conservative when the extreme wind pressure events among different sectors are independent. 2) The result obtained by the first-order method for a high return period is not significantly affected when the extreme wind speeds among the different sectors are assumed to be independent. These two assumptions are validated by examples in different regions and theoretical derivation.

윤활시스템에서 극압첨가제 조성에 따른 마모특성 연구 (A Study on the Wear Properties by EP(Extreme Pressure) Additive Composition in a Lubricated Concentrated Contact)

  • 김용석;류재환
    • Tribology and Lubricants
    • /
    • 제19권3호
    • /
    • pp.159-166
    • /
    • 2003
  • This research for replacement of chlorine or sulfur based EP(extreme pressure) -additives which is restricted materials by environmental regulation. The subject of this study is as follows, 4-ball test and friction coefficient test were experimented in accordance with temperature and velocity, compounding with several organic or inorganic metallic elements. After 4-ball test, wear area of steel ball was analysed by SEM-EDX. As the analysis, organic and inorganic elements make a effect for extreme pressure lubricity. It is shown that the friction coefficient of lubricant which includes chlorine or sulfur additives, the scoring phenomenon is found accord-ing to temperature and the scuffing phenomenon at 200$^{\circ}C$. Applying to Na, P, S, Zn, Ca based on inorganic and organic elements, the result showed that friction coefficient is decreased more and more, as increasing temperature of lubricant. The additive based on S, Cl, P elements is effect far extreme pressure in the sample#1 and Na, P, S, Zn, Ca in sample #2. These elements are environmental contaminants and S, Cl based on EP additives which are very popular in domestic industry, when they are properly composed with non-chlorine based on additives and Na, P, S, Zn, Ca organic or inorganic elements. It is showed that lubricity and excellent anti-wear properties.

Prediction of Extreme Sloshing Pressure Using Different Statistical Models

  • Cetin, Ekin Ceyda;Lee, Jeoungkyu;Kim, Sangyeob;Kim, Yonghwan
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.185-194
    • /
    • 2018
  • In this study, the extreme sloshing pressure was predicted using various statistical models: three-parameter Weibull distribution, generalized Pareto distribution, generalized extreme value distribution, and three-parameter log-logistic distribution. The estimation of sloshing impact pressure is important in design of liquid cargo tank in severe sea state. In order to get the extreme values of local impact pressures, a lot of model tests have been carried out and statistical analysis has been performed. Three-parameter Weibull distribution and generalized Pareto distribution are widely used as the statistical analysis method in sloshing phenomenon, but generalized extreme value distribution and three-parameter log-logistic distribution are added in this study. Additionally, statistical distributions are fitted to peak pressure data using three different parameter estimation methods. The data were obtained from a three-dimensional sloshing model text conducted at Seoul National University. The loading conditions were 20%, 50%, and 95% of tank height, and the analysis was performed based on the measured impact pressure on four significant panels with large sloshing impacts. These fittings were compared by observing probability of exceedance diagrams and probability plot correlation coefficient test for goodness-of-fit.

불소계 폴리올에스테르의 합성과 윤활 특성 (Synthesis and Lubrication Properties of Semi-Fluorinated Polyol Esters)

  • 백진욱;정근우;김영운
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.149-155
    • /
    • 2001
  • New semi-fluorinated polyol esters were synthesized by condensation reaction of polyols (NPG and TMP) and carboxylic acids such as 2-ethylhexanoic acid, stearic acid and perfluorooctanoic acid. The structures of polyol esters were confirmed by FT-IR and H-NMR etc. And, the fluorinated polyol esters were insoluble in several oils, however, the semi-fluorinated polyol esters were soluble in several oils depended on the structure of polyol esters. The physical properties such as 4-ball wear property and extreme-pressure (EP) properties were characterized by measuring wear scar diameter through ASTM D2266 and by determining the load-carrying through ASTM D2783 method, respectively. As the results, wear scar diameters of oils in which the semi-fluorinated polyol esters were added were not changed compared to those of not added oils. While extreme-pressure properties remarkably Increased with fluorine contents of the esters depended on the structure of acid moiety and polyol moiety. Also, the extreme-pressure property of semi-fluorinated NPG polyol ester in gasoline engine oil was better than that of commercial Teflon coating additive.

  • PDF

우리나라 겨울철 극한저온현상 발생 시 종관 기후 패턴 (Synoptic Climatic Patterns for Winter Extreme Low Temperature Events in the Republic of Korea)

  • 최광용;김준수
    • 대한지리학회지
    • /
    • 제50권1호
    • /
    • pp.1-21
    • /
    • 2015
  • 본 연구에서는 지난 40년 동안(1973~2012)의 우리나라 기상청 산하 61개 지점 일기온 자료와 NCEP/NCAR 재분석 자료를 바탕으로 우리나라 지역별 겨울철 극한저온현상 발생 시 동아시아 영역의 종관 기후 패턴의 특징을 밝히고자 하였다. 일최고기온과 일최저기온 하위 10 퍼센타일 기준으로 정의된 겨울철 극한저온현상은 주로 겨울철 전반기(12월 초순~1월 중순)에 2~7일 간격으로 우리나라 전역 또는 주요 산맥 기준 동서지역으로 구분되어 발생함을 알 수 있다. 해수면기압과 바람벡터 등의 지상 종관 자료 합성장 분석에 따르면 총 13개로 구분되는 우리나라 겨울철 극한저온현상 발생 공간 패턴은 산맥뿐만 아니라 시베리아 고기압과 알류샨 저기압의 상대적인 확장 범위와 강도와 밀접한 관련성이 있음을 알 수 있다. 대류권 중층(500 hPa) 종관기후도 분석에 따르면, 블러킹 형태의 저기압이 상층 찬 공기를 고위도 지역에서 한반도로 이류시킬 때 우리나라에 겨울철 극한저온현상이 발생하기에 적합한 조건이 형성됨을 알 수 있다. 이러한 결과들은 지역규모 이상의 동아시아 겨울철 극한저온현상 예보를 향상시키기 위해 시베리아 고기압, 알류샨 저기압, 상층 블러킹 등의 종관 기후 요소를 모니터링하는 것이 중요함을 가리킨다.

  • PDF

Wind loads on T-shaped and inclined free-standing walls

  • Geurts, Chris;van Bentum, Carine
    • Wind and Structures
    • /
    • 제13권1호
    • /
    • pp.83-94
    • /
    • 2010
  • Wind tunnel measurements on T-shaped free-standing walls and inclined free-standing walls have been carried out. Mean net pressure coefficients have been derived and compared with previous research. It was observed that the high loads at the free ends are differently distributed than those derived from the pressure coefficients for free-standing walls in EN 1991-1-4. In addition net pressure coefficients based on extreme value analysis have been obtained. The lack of correlation of the wind induced pressures at windward and leeward side result in lower values for the net pressure coefficients when based on extreme value analysis. The results of this wind tunnel study have been included in Dutch guidelines for noise barriers.

고혈압환자의 폭염 적응력 증진을 위한 프로그램 효과 (Effects of an Extreme Heat Adaptation Program in Hypertensive Patients)

  • 정성희;김남순;채수미;이은주
    • Journal of Korean Biological Nursing Science
    • /
    • 제16권3호
    • /
    • pp.164-172
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the effects of an extreme heat Adaptation Program on the blood pressure, stress response, self-efficacy, and knowledge of management of hypertension and extreme heat of patients who suffered from hypertension. Methods: A quasi-experimental study with a non-equivalent control group pretest-posttest design was used. The data collection period was between July 2 and August 20, 2012. Thirty-seven patients participated in the study (18 in the experimental group and 19 in the control group). Data were analyzed using $X^2$-test, t-test, and Cronbach's alpha coefficients with SPSS/WIN 19.0. Results: Patients who participated in the program showed statistically significant improvements in systolic blood pressure (SBP), self-efficacy, and knowledge of management of hypertension and extreme heat. Conclusion: The results indicate that this extreme heat adaptation program can be utilized for patients suffering from hypertension in order to reduce their SBP and to increase self-efficacy and knowledge of management of hypertension and extreme heat. Therefore, it is recommended that this program be used for elderly patients suffering from chronic disease.

기유와 극압제가 압연유의 윤활성 및 내소부성에 미치는 영향 (Influence of Base Oils and Extreme Pressure Additives on Lubricity and Anti-Seizure Property of Lubricant in Cold Rolling)

  • 한석영;송교봉;이준정
    • 대한기계학회논문집
    • /
    • 제16권7호
    • /
    • pp.1363-1372
    • /
    • 1992
  • 본 연구에서는 고속 냉간 압연유를 개발하기 위한 기초 연구로써 압연유의 기본이 되는 기유의 종류와 압연유에 첨가되는 각종 첨가제중 고속, 고압하 압연에서 가장 문제가 되는 히트 스크래치를 방지하는 역할을 하는 극압제의 종류 및 함량이 압연유의 윤활성과 내소부성에 어떠한 영향을 주는가를 소다식 진자형 마찰계수 시험 기, Falex 시험기 그리고 Four Ball 시험기와 같은 실험실적 평가방법과는 달리 실제 롤과 스트립 사이의 접촉조건이 상사한 시험압연기를 사용한 윤활성 및 내소부성 평가 실험을 통하여 검토하였다. 본 평가 실험에 사용된 시험압연기는 압하배분, 압연 채 터링(chattering), 장력 제어, 압연윤활 특성, 압연재 형상 제어, 이주속 압연특성 등 을 시험할 수 있는 다목적 냉간압연기로써 그 구조와 제원을 Fig.1과 Table 1에 나타 내었다. 또한 극압제를 함우하고 있는 압연유와 스트립 표면간의 화학반응에 의한 극압막의 존재여부를 확인하기 위하여 EDS(energy dispersive spectrometer) 분석법과 ESCA (electron spectroscopy for chemical analysis) 분석법을 이용하여 분석하였다.

FCEV 충전 시스템 체크밸브의 수소 유입 극한 온도 조건에 따른 유동 성능 인자 분석 (Analysis of Flow Performance Factors According to Extreme Temperature Conditions of Hydrogen Inflow of FCEV Charging System Check Valve)

  • 오승훈;서현규
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.514-525
    • /
    • 2023
  • This study conducted numerical simulations with the purpose of analyzing the impact of variations in outlet pressure conditions under extreme temperature conditions on the fluid dynamics and performance of a check valve utilized in hydrogen refueling systems. Under the extreme temperature conditions, changes in outlet pressure conditions of the check valve were investigated to analyze velocity distributions, pressure distributions, and temperature distributions in the operational and connection regions. The analysis results indicated that changes in outlet pressure had a significant influence on the internal temperature variation of the check valve. Furthermore, due to density variations in the connection region caused by the cooling effect of excessively cooled hydrogen, a bias in the primary flow direction towards the lower part of the valve outlet was observed in the outlet area. Through a comparison of the results of the valve's inherent flow performance, represented by the flow coefficient, it was observed that when the pressure difference between the inlet and outlet was below 0.37 MPa, sufficient flow was not ensured.