• Title/Summary/Keyword: Extraction time

Search Result 3,564, Processing Time 0.027 seconds

Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride (염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건)

  • Hong, Joo Youn;Kim, Chi Nyon;Jung, Jae Hoon;Chang, Jung Hwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF

Generation of the Building Layer of Large-scale Digital Map Using Multi-Oblique Images (다방향 경사영상을 이용한 대축척 수치지도 건물레이어 제작)

  • Song, Jai-Youl;Lee, Byoung-Kil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.6
    • /
    • pp.621-629
    • /
    • 2011
  • According to the development of technologies for generating the 3D spatial information, the needs for producing and updating the precise 3D objects with LoD 4 level are increased. On the other hand, the needs for real-time updating of 2D digital maps are expanded, based on the execution of various GIS projects. These 2D informations can be extracted from precisely constructed 3D spatial information, to do this the feasibility studies on extraction of the 2D information from the 3D spatial information is needed. In this study, 3D objects are modeled using multi-oblique images, and the objects are stereo-plotted using digital airborne images, as well. Then the two data sets are compared and analyzed. The results show that the accuracy assessments fulfill the 1/1,000 digital map accuracy standard of regulations for photogrametric surveying of National Geographic Information Institute, but the shapes and the areas of building objects are different between two data sets because of the portrayal standards. Consequently, researchers can conclude that it is possible to generate the building layer of large scale topographic map using multi-oblique images, but additional researches is needed to resolve the problems on differences of the portrayal standards.

The Development of Water Quality Monitoring System and its Application Using Satellite Image Data

  • Jang, Dong-Ho;Jo, Gi-Ho
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.376-381
    • /
    • 1998
  • In this study, we was measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be loaded in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. Also we investigated the possibility of extraction of water quality factors in rivers and water body by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract the environmental factors related with eutrophication, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible rays bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation were there. And at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible rays bands, the spectrum was highest. Second, as a result of the radiance reflectance Chlorophyll-a represented high spectral reflectance mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high spectral reflectance at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$ each. Third, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution chart when carried out ratio of B3 and BS to B7. And Band 7 was useful for making the distribution chart of suspended sediments. And when we carried out PCA, suspended sediments and turbidity had distributions at PC 1 , PC 4 each similarly to ground truth data. Above results can be changed according to the change of season and time. Therefore, in order to analyze more exactly the environmental factors of water quality by using LRC data, we need to investigate constantly the ground truth data and the radiance feature of reflectance of water body. Afterward in this study, we will constantly analyze the radiance feature of the surface of water in water body by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFs). Besides, we will gather the data of water quality analysis in water body and analyze the pattern of water pollution.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Classification of Ultrasonic NDE Signals Using the Expectation Maximization (EM) and Least Mean Square (LMS) Algorithms (최대 추정 기법과 최소 평균 자승 알고리즘을 이용한 초음파 비파괴검사 신호 분류법)

  • Kim, Dae-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Ultrasonic inspection methods are widely used for detecting flaws in materials. The signal analysis step plays a crucial part in the data interpretation process. A number of signal processing methods have been proposed to classify ultrasonic flaw signals. One of the more popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature spare. This paper describes an alternative approach which uses the least mean square (LMS) method and exportation maximization (EM) algorithm with the model based deconvolution which is employed for classifying nondestructive evaluation (NDE) signals from steam generator tubes in a nuclear power plant. The signals due to cracks and deposits are not significantly different. These signals must be discriminated to prevent from happening a huge disaster such as contamination of water or explosion. A model based deconvolution has been described to facilitate comparison of classification results. The method uses the space alternating generalized expectation maximiBation (SAGE) algorithm ill conjunction with the Newton-Raphson method which uses the Hessian parameter resulting in fast convergence to estimate the time of flight and the distance between the tube wall and the ultrasonic sensor. Results using these schemes for the classification of ultrasonic signals from cracks and deposits within steam generator tubes are presented and showed a reasonable performances.

Accuracy Assessment of Feature Collection Method with Unmanned Aerial Vehicle Images Using Stereo Plotting Program StereoCAD (수치도화 프로그램 StereoCAD를 이용한 무인 항공영상의 묘사 정확도 평가)

  • Lee, Jae One;Kim, Doo Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.257-264
    • /
    • 2020
  • Vectorization is currently the main method in feature collection (extraction) during digital mapping using UAV-Photogrammetry. However, this method is time consuming and prone to gross elevation errors when extracted from a DSM (Digital Surface Model), because three-dimensional feature coordinates are vectorized separately: plane information from an orthophoto and height from a DSM. Consequently, the demand for stereo plotting method capable of acquiring three- dimensional spatial information simultaneously is increasing. However, this method requires an expensive equipment, a Digital Photogrammetry Workstation (DPW), and the technology itself is still incomplete. In this paper, we evaluated the accuracy of low-cost stereo plotting system, Menci's StereoCAD, by analyzing its three-dimensional spatial information acquisition. Images were taken with a FC 6310 camera mounted on a Phantom4 pro at a 90 m altitude with a Ground Sample Distance (GSD) of 3 cm. The accuracy analysis was performed by comparing differences in coordinates between the results from the ground survey and the stereo plotting at check points, and also at the corner points by layers. The results showed that the Root Mean Square Error (RMSE) at check points was 0.048 m for horizontal and 0.078 m for vertical coordinates, respectively, and for different layers, it ranged from 0.104 m to 0.127 m for horizontal and 0.086 m to 0.092 m for vertical coordinates, respectively. In conclusion, the results showed 1: 1,000 digital topographic map can be generated using a stereo plotting system with UAV images.

Comparison of residue patterns between foliar application and drenching in export strawberry (경엽 및 관주 처리에 따른 딸기 중 침투성 농약 잔류패턴 비교)

  • Lee, Hyo-Sub;Hong, Su-Myeong;Kwon, Hye-Young;Kim, Dan-bi;Moon, Byeong-Chul
    • Journal of Applied Biological Chemistry
    • /
    • v.60 no.4
    • /
    • pp.313-319
    • /
    • 2017
  • Strawberries are one of the main commodities in Korea and have been exported over 30 million dollar. And the safety has recently become an important issue in the agro-trade, pesticide residue is most important matter of safe agricultural products. As strawberries can be cultivated using elevated production system, so it is possible to use the drenching. When spraying the pesticides, the use of drenching can be lower amount of residual than using foliar treatment. In this study, time sequential residual amount of pesticides were compared between drenching and foliar application in strawberries. Pesticides were treated with the standard and double dosage and samples were collected at 0, 3, 6, 9, 13, 16 and 21 day and analyzed by LC and LC-MS/MS after liquid-liquid extraction and QuEChERS. Two pesticides were detected less than 1 mg/kg in all samples for drenching treatment. Carbendazim residues in drenching treatment were 5 to 25 times lower than foliar application. And azoxystrobin was not detected in strawberries of drenching treatment.

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

Investigation on Translocation of De-icing Salts influenced by the Intensity of Foliar Damage of Roadside Trees in Chung-ju City (충주시 가로수의 황변정도에 따른 토양 내 제설제 성분의 흡수이행성 평가)

  • Kim, Jae-Young;Kim, Won-Tae;Yoon, Young-Han;Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • Use of de-icing salts results in accumulation of high concentrations of ions on roadside soils and tree. The purpose of this study isto determine translocation of seasonal impact of exchangeable cations originating from de-icing salt on roadside surface soil-plant influenced by the intensity of foliar damage (NY = 0-25%, SY = 26-50%, CY = 51-75%) of trees. This paper investigated the concentration of four exchangeable cations ($K^+$, $Ca^{2+}$, $Na^+$, and $Mg^{2+}$) on the roadside surface soil. The tree (Ginko biloba) samples were collected from the Konkuk and Judeok intersections in Chung-ju city. The sequential extraction procedure was applied to 120 soil samples of the soilsurface and 30 tree samples. Four cation exchange ions were determined by ICP-OES. The content of four exchangeable cations present on roadside soil was found to be the lowest in NY but highest in CY from tree pits in the order of NY < SY < CY. Especially, the results were apparent during spring time compared to other seasons. Soil collected from tree pits had the highest concentration of $Ca^{2+}$ possibly due to a higher volume of traffic on those streetsresulting in splashing of more calcium chloride ($CaCl_2$). The analysis of three exchangeable cations ($K^+$, $Mg^{2+}$, and $Na^+$) in the tree leaves revealed higher levels than roadside surface soil when foliar damage ratio increased in the order of NY < SY < CY in summer. In addition, a strong positive linear relationship was observed between the concentration of exchangeable cations in soil and trees. It is hypothesized that the results of this study can be a valuable baseline for managing de-icing salt on roadside soil and trees, in order to mitigate the salt stress that can damage the roadside soil and trees.

Volatile Flavor Components of Angelica gigas Nakai by the Storage Conditions (저장조건에 따른 당귀의 정유성분 변화)

  • Choi, Sung-Hee;Kim, Hye-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.513-518
    • /
    • 2000
  • Volatile flavor components of Angelica gigas Nakai affected by different storage time and temperature were investigated. The aroma compounds was extracted by a simultaneous distillation and extraction method using a Likens and Nickerson's apparatus. The concentrated extract was analyzed and identified by GC and GC-MS equipped polar and nonpolar column. The yields of volatile concentrates of Angelica gigas Nakai by low temperature storage were larger than those by room temperature storage. The GC patterns of the flavor components of both resembled but the peak area of each flavor compounds was little different. Main volatile flavor components of Angelica gigas Nakai by using polar column were ${\alpha}-pinene$, ${\beta}-pinene$, terpineol, farnesol, cadinene, guaiol, isolongifolene and eudesmol etc. Main volatile flavor components of Angelica gigas Nakai by using nonpolar column were camphene, ${\beta}-pinene$, elemol, eudesmol etc.

  • PDF