• Title/Summary/Keyword: Extracorporeal Circulation

Search Result 166, Processing Time 0.021 seconds

Clinical Analysis of Mitral Valvular Disease (승모판막 질환의 임상적 고찰)

  • 김창수
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.382-389
    • /
    • 1991
  • The clinical observations on the 63 cases of the mitral valvular heart disease treated in the department of Thoracic and Cardiovascular Surgery, Kosin medical college, during the period of 5 years from January, 1986 to December, 1989, are as follows. 1. Total 63 cases, 23 were male and 40 were female with sex ratio of 1: 1.7. 2. The age distribution was widely varied from 7 years of the youngest to 65 years oldest, average age was 35.3 year old. 3. The main clinical symptom and sign were D.O.E, general weakness, fatigability, palpitation, chest pain, hepatomegaly, pitting edema and both neck vein distension. 4. The preoperative N.Y.H.A functional classification were class II, III, IV in 28%, 54%, 16%. 5. The preoperative diagnosis were MS - 6.3%, MR - 53.9%, MSR - 36.5%, MVP - 3.1%. 6. All 63 patients were operated on the under direct vision using extracorporeal circulation, MVR in 18 cases, MVR and Tricuspid annuloplasty in 24 cases, DVR in 3 cases, DVR and Tricuspid annuloplasty in 5 cases, TVR in 1 case, Mitral annuloplasty in 4 cases, mitral valvuloplasty in 7 cases and mitral commissurotomy in 2 cases 7. The operative mortality was 7.9%, and 5 years actuarial survival rate was 89%.

  • PDF

Surgical Results of Brock Operation with a Mosquito Clamp in Neonates (Mosquito 겸자를 이용한 Brock 술식의 단기 성적 -중증 폐동맥유출로차단을 동반한 신생아 4예-)

  • 안홍남
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.766-774
    • /
    • 1989
  • Four neonates with critical pulmonary outflow obstruction underwent emergency palliative operation between February 1988 and May 1989 at the department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital. There were three boys and one girl, the mean age was 12.25 days [ranging from 3 days to 26 days], and the mean body weight was 3,625 gm [ranging from 3,450 gm to 4,200 gm]. Two patients had severe pulmonic valvular stenosis with intact ventricular septum, a third had pulmonary atresia with intact ventricular septum, and another had pulmonary atresia with ventricular septal defect. All were cyanotic, showed arterial desaturation with metabolic acidosis, and had congestive heart failure. To relieve the pulmonary outflow tract obstruction, we performed transventricular pulmonary valvulotomy [Brock operation] with a mosquito clamp in all cases without extracorporeal circulation. Three patients survived the operation and showed satisfactory postoperative results. The patient who had pulmonary atresia with ventricular septal defect expired 5 days after surgery. We consider transventricular pulmonary valvulotomy [Brock operation] with a mosquito clamp as one of the preferable procedures for critical pulmonary outflow obstruction in the neonatal period.

  • PDF

Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System (이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조)

  • Lee, Dong-Hyup;Lee, Jang-Hoon;Jung, Tae-Eun
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.512-516
    • /
    • 2007
  • A mechanical circulatory support system is a life-saving option for treating acute severe respiratory failure or cardiac failure. There are currently a few types of assist devices and the Twin-Pulse Life Support (T-PLS) system is a kind of pulsatile pump. We report here on three patients with severe life threatening cardiopulmonary dysfunction who had the T-PLS system used as an assist device. The indications for applying the T-PLS system were continuing respiratory or cardiac failure in spite of maximal ventilatory and inotropic support. There were two patients with acute respiratory failure due to infection and one patient with cardiac failure due to acute myocarditis. One respiratory failure patient and one cardiac failure patient survived after applying the T-PLS system for 3 days and 5 days, respectively. The T-PLS system is useful as an assist device and it should be considered before multi-organ failure occurs.

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.

Effect of Fructose-1,6-diphosphate[FDP] on Red Blood Cells after Extracorporeal Circulation (체외순환후 fructose-1,6-diphosphatate[FDP]가 적혈구에 미치는 영향)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.693-701
    • /
    • 1992
  • Extracorporeal cardiopulmonary bypass[CPB] has been associated with a wide variety of hematologic derangements, including a transient deformation and hemolysis of red blood cells[RBCs], which is supposed to be due to mechanical trauma and/or metabolic alterations. Since membrane integrity is, in part, maintained by energy requiring process, inadequate function of erythrocyte glycolytic pathway, which is inevitalble during CPB, may cause depletion of high energy phosphate pool and result in hemolysis. The authors performed an investigation to assess whether administration of Fructose-l, 6-diphsphate [FDP], which has been known to enhance intracellular glycolytic activities, could counteract erythrocyte hemolytic events caused by CPB. Sixty pateints with cyanotic congenital heart diseases, who underwent open heart surgery under CPB longer than 60 minutes, were randomly divided into two groups depending on whether use of FDP[Group FDP] or not[Group Control]. The age, sex, CPB time, preoperative hemoglobin level, disease entities were all similar[Table 1], and membrane type oxygenators were used in all patients. In Group, FDP, a dose of 250mg/kg body weight of FDP was administered by intravenous dripping every 12 hours from the morning of the operation to postoperative 48 hours, To demonstrate the degree and pattern of hemolysis of erythrocyte, reticulocyte count, indirect /direct bilirubin, haptoglobin, plasma hemoglobin, lactate dehydrogenase were measured every 12 hours from the time of cessation of CPB to 48 hours and RBC morphologic study, osmotic fragility test were done every 24 hours. All parameters revealed less hemolytic in group FDP [Fig. 1~5], though the differences between two groups were not significant, except plasma hemoglobin, lactate dehydrogenase changes. A pattern of sequential changes of plasma hemoglobin, lactate deh-ydrogenase showed the highest level at the time of CPB stop and abrupt decrease in following 24 hours in both groups, and statistically significant differences were demonstrated in group FDP at least for the first 12 hours postoperatively[p<0.05]. The authors conclude that they can expect the benificial effect of FDP on the maintenance of membrane stability of RBC probably by energy enhancement during the shock status of CPB, but FDP could not completely prevent the damaging effect on RBC by cardiopulmonary bypass

  • PDF

On-Pump versus Off-pump Myocardial Revascularization in Patients with Renal Insufficiency: Early and Mid-term Results

  • Kim, Hwan-Wook;Lee, Jae-Won;Je, Hyung-Gon;Choi, Soo-Hwan;Jo, Keon-Hyon;Song, Hyun
    • Journal of Chest Surgery
    • /
    • v.44 no.5
    • /
    • pp.323-331
    • /
    • 2011
  • Background: Myocardial revascularization in patients with renal insufficiency is challenging to the cardiac surgeon, irrespective of utilizing extracorporeal circulation. This study aimed to compare the number of bypass grafts and the mid-term results and to evaluate independent survival predictors in patients with renal insufficiency undergoing on-pump or off-pump myocardial revascularization. Materials and Methods: We retrospectively analyzed the data of 103 patients with renal insufficiency, who had isolated myocardial revascularization between January 1999 and January 2009. The patients were divided into two groups, the on-pump group and the off-pump group. Results: The off-pump group received a significantly greater number of distal arterial grafts than the on-pump group. However, the mean number of total grafts, the degree of complete revascularization, and survival rate of the patients were not significantly different between the two groups. Multivariate analysis showed the independent predictors for reduced mid-term survival were the number of total grafts and postoperative periodic renal replacement therapy. Off-pump myocardial revascularization does not decrease the number of bypass grafts or influence on the mid-term results for patients with renal insufficiency, compared to on-pump myocardial revascularization. Conclusion: Myocardial revascularization with a large number of total grafts has a beneficial effect on survival in patients with renal insufficiency, irrespective of utilizing extracorporeal bypass.

Changes in Blood Glucose and Electrolyte During Open Heart Surgery (저체온 개심술시 혈당 및 전해질치의 변화에 관한 연구)

  • Yoo, Byeung-Lyeul;Kim, Heung-Dae;Lee, Tae-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.1
    • /
    • pp.65-74
    • /
    • 1987
  • This study deals with the changes in the concentrations of blood glucose and electrolytes during open heart surgery. Blood glucose and electrolytes in connection with age, disease and anesthetic period were measured in 25 patients about to undergo heart surgery which were performed between June 1986 and August 1986 in Yeungnam University Hospital. Because glucose solution is commonly used as priming solution, and the priming solution is hyperglycemic and hyperosmolar, glucose level of priming solution in this study was adjusted to 100-200mg% level to minimize hyperglycemic and hyperosmolar effect. The following results were obtained. 1. Glucose level of priming solution before extracorporeal circulation was $151.6{\pm}3.13mg%$. 2. With body cooling, blood glucose level was elevated. As duration of extracorporeal circulation is prolonged, blood glucose level was elevated more, but no difference between age and diseases were observed. On warming, blood glucose level was progressively lowered. 3. Despite the low serum potassium level during by pass, the potassium level was progressively elevated following by-pass, cut the serum potassium level was low compared to control values. Elevated calcium level was maintained during by pass.

  • PDF

Experimental Studies on Extracorporeal Circulation by Rygg-Kyvsgaard Heart-Lung Machine, Hartman`s Solution Prime,and Moderate Hypothermia: [Part I] (Hartmann`s 용액으로 충진한 혈희석 체외순환에 관한 실험적 연구: (1보: 심폐기 Rygg-Kyvsgaard 의 혈산화와 혈압 및 혈액상에 미치는 영향))

  • 지행옥
    • Journal of Chest Surgery
    • /
    • v.4 no.2
    • /
    • pp.69-80
    • /
    • 1971
  • Total body perfusion using Rygg-Kyvsgaard Heart-Lung-Machine, Mark IV, Polystan was attempted in the dogs by the hemodilution method with total prime of buffered Hartman's solution and under hypothermia. The first of all, the functions of Rygg--Kyvsgaard Heart-Lung-Machine and the effects of the hemodilution perfusion by buffered Hartman's solution was studied. At the same time the changes of blood pressure, oxygen consumption, and influence on the blood pictures were observed before, during, and in 1-3 days after perfusion. Hemodilution rates were the average 74. 22cc/Kg(the ranges of 67 to 81 cc/Kg) and perfusion flow rates were maintained in the mean 62. 6cc/Kg/min., Although it was possible to check up to 87 cc/ Kg/min. The total body perfusion continued for 60-80 minutes. Hypothermia was employed between $36^{\circ}C$ and $32^{\circ}C$ of the rectal temperature. Arterial pressure was ranged approximately between 68mmHg and 149mmHg, but generally, it was maintained over 80mmHg. Venous pressure was measured between 6.5cm $H_2O$and 11.5cm $H_2O$. Optimum oxygenation can be expected when oxygen flow into the disposable bubble oxygenator was maintained approximately at 3.5 L/min .. Inthis way, the oxygen contents were measured in the mean value of 13.11${\pm}$O.56 vol. % of arterial blood and 8.67+1.08 vol.% of venous blood(P${\pm}$0.86 vol.% in arteriovenous oxygen difference and 2. 97${\pm}$0.62cc/Kg in oxygen consumption were calculated. According to these dates, it is as plain as pikestaff that excellent oxygenation and good tissue perfusion was accomplished. Erythrocyte, hemoglobin and hematocrit were decreased about 38% during extracorporeal circulation and these were not recovered until 1-3 days after perfusion. These decrease was resulted from relatively high degree of hemodilution rate and no blood transfusion to compensate during these experimental studies. The platelets were also decreased about 76% during perfusion, but on the contrary, it was increased progressively after perfusion and in 1-3 days after perfusion was returned to the control level. Leucocyte were also decreased during perfusion, but it was increased progessively after perfusion and in 1-3 days after perfusion exceed the control level. This increase was resulted from postoperative infection of the wound, but its analysis were not changed significantly.

  • PDF

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

Percutaneous Extracorporeal Membrane Oxygenation for Graft Dysfunction after Heart Transplantation

  • Lim, Jae Hong;Hwang, Ho Young;Yeom, Sang Yoon;Cho, Hyun-Jai;Lee, Hae-Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.100-105
    • /
    • 2014
  • Background: We evaluated the safety and efficacy of percutaneous extracorporeal membrane oxygenation (ECMO) in patients with primary graft dysfunction after heart transplantation. Methods: Of 65 patients (44 males and 21 females) who underwent heart transplantation from January 2006 to December 2012, 13 patients (group I) needed peripheral ECMO support due to difficulty in weaning from cardiopulmonary bypass (CPB) and 52 patients (group II) were weaned from CPB without mechanical support. The mean age of the patients at the time of operation was $54.4{\pm}13.6$ years. There were no differences in the preoperative characteristics of the two groups. Multivariable analysis was performed to identify the risk factors for ECMO therapy. Results: All group I patients were successfully weaned from ECMO after $53{\pm}9$ hours of circulatory support. Early mortality occurred in four patients (1 [7.7%] in group I and 3 [5.8%] in group II, p>0.999). There were no differences in the postoperative complications between the two groups, with the exception of reoperation for bleeding. A greater number of group I patients underwent reoperation for bleeding (5 [38.5%] in group I vs. 6 [11.5%] in group II, p=0.035). In multivariable analysis, preoperative mechanical support (ECMO and intra-aortic balloon pump) and longer CPB time were the risk factors of ECMO therapy for graft dysfunction (odds ratio, 6.377; 95% confidence interval, 1.519 to 26.77; p=0.011 and odds ratio, 1.010; 95% confidence interval, 1.001 to 1.019; p=0.033). Conclusion: Percutaneous ECMO support could be a viable option for rescuing patients when graft dysfunction refractory to medical management develops after heart transplantation.