• 제목/요약/키워드: Extinguishing concentration

검색결과 53건 처리시간 0.023초

환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구 (A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities)

  • 전용한;한상필
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

UV 화염감지기의 감지성능에 대한 분진분위기의 영향 (Influence of Dust Environment on the Detection Capability of Ultraviolet Flame Detector)

  • 김홍;호예
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.113-119
    • /
    • 1997
  • UV 화염감기의 분진분위기에서의 성능저하를 고찰하기 위하여 세제분말, 탄진 및 분말 소화약제의 분진운을 형성하였고 LPG 및 가솔린 화염을 사용하여 UV 화염감지기의 감지성능을 고찰하였다. 분진 분위기 하에서의 UV 화염감지기의 성능을 분진의 농도와 분진층의 거리가 증가함에 따라 뚜렷한 증가를 보였으며, 분진의 화학적, 물리적 특성에 커다란 영향을 받았다. 따라서 UV 화염감지기를 분진 분위기에서 사용한 경우 특별한 주의를 기울일 필요가 있는 것으로 사려된다.

  • PDF

계면활성제 첨가에 따른 함수율에 관한 실험적 연구 (Experimental Study on Moisture Content According to Addition of Surfactants)

  • 김남균;이동호
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.79-83
    • /
    • 2015
  • 화재사고는 그 충격과 영향이 업무중단 및 기업의 존폐를 좌우 할 수 있는 대표적인 재난 유형이다. 따라서 사전 예방, 대비는 물론 재난 발생 시 신속한 초기대응이 매우 중요하다. 현재 운용되고 있는 저탄장 및 합판 가공 산업 분야 등에서는 다공성 가연물의 저장이 불가피하다. 다공성 가연물 저장 공간의 화재는 그 특성상 발화시점의 파악 및 초기진압이 어려우며, 초동 대처에 실패할 경우 표면화재에서 심부화재로 이어져 2차 화재피해가 발생할 가능성이 높다. 또한 심부화재는 다량의 독성가스발생과 재발화로 인해 인적 물적 피해를 야기할 수 있으므로 다공성 가연물을 취급하는 저장공간을 중심으로 피해경감 대책이 요구된다. 본 연구는 침윤소화약제 사용 시 다공성 물질의 심부화재 소화 효율 증대에 관한 기초 연구로써, 계면활성제의 농도에 따른 침투성능의 향상에 관한 연구를 수행하였다. 실험에 사용된 다공성 물질은 국내 사용 목재의 75%를 점유하고 있는 뉴질랜드산 소나무의 원목 목분을 사용하였다. 소화용수는 침윤소화약제에 사용되고 있는 Butyl Di Glycol (BDG)을 선택하여 농도에 따른 표면장력별 표준시료를 제작하여 실험을 수행하였다. 실험은 NFPA 18의 Deep-Seated Fire Test를 기초로 수행하였으며, 살수량과 다공성 물질 내부로의 침투량, 다공성 물질 외부로의 배출량 측정 실험을 실시하였다. 실험결과 계면활성제 농도에 따른 표면장력이 감소함에 따라 거시적 침투속도는 감소하나 다공성 물질 내부로의 침투량은 증대되는 특성을 확인하였다.

$CO_2$ 소화제 노즐 분사각 및 분사속도가 $CO_2$ 농도분포특성에 미치는 영향에 관한 수치적 연구 (A Numerical Simulation of the Effect of the Injection Angle and Velocity of the $CO_2$ Agent Nozzle on the Characteristics of $CO_2$ Concentration Distribution)

  • 박찬수
    • 한국화재소방학회논문지
    • /
    • 제20권2호
    • /
    • pp.44-53
    • /
    • 2006
  • 선박에 설치되는 고정식 $CO_2$ 소화장치의 구성요소 중 하나인 $CO_2$ 소화제분사노즐의 분사각과 분사속도가 유동 및 $CO_2$ 농도분포특성에 미치는 영향을 분석하기 위하여 전산모의실험을 2차원 비정상상태로 수행하였다. 유동장과 $CO_2$ 소화제 농도장을 계산하여 분석하였다. 소화제 분사노즐의 조건에 따라 유동형태의 상이성을 확인할 수 있었으며, 모든 소화제 분사노즐조건에서 와류가 형성되는 영역으로부터 주위로 등농도선대가 확장됨을 알 수 있었다. 소화제 분사노즐각에 따라 계산영역의 밑바닥면을 따르는 벽면제트기류의 강도가 다르게 나타났고, 등농도선대가 확장 또는 축소됨을 예측 가능하였다. $CO_2$ 소화제 분사유량을 일정하게 유지한 상태에서 소화제 분사속도를 증가시키는 것이 감소시키는 것 보다 더 높은 $CO_2$ 등농도선대가 밑바닥면 상에 형성될 것으로 예측되었다.

가스계 소화시스템관련 안전기술 (A Technical Description on The Safety Aspects related To Gas Suppression Fire Protection System)

  • 이창욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2002년도 춘계학술대회 논문집
    • /
    • pp.21-29
    • /
    • 2002
  • 가스계 소화약제시스템의 인명안전 또는 기타 안전관련으로 CO2 시스템과 청정약제시스템을 중심으로 기술해보았습니다. 인명에 대한 위험을 최소화하면서 CO2 소화시스템의 혜택을 얻기 위해서는 설계, 시공, 유지관리면에서의 인명안전에 대해 상당한 관심을 기울여야한다. 청정 소화약제를 통상의 거주구역에 사용할 경우의 주요요소는 독성문제이다. 할로겐화탄소약제 테스트에서의 주요 관점은 급성효과, 즉 단기간 노출의 경우이다. 주요급성효과에는 마취성과 심장감작성이 있다. 불활성가스약제의 경우 주요 신체적 영향으로는 산소농도의 저하문제를 들 수 있다.

  • PDF

비이온성 계면활성제가 함유된 수용액의 특성과 소화성능 (Characteristics of Water Solutions Containing Nonionic Surfactants and Their Fire Fighting Performance)

  • 이윤우;이윤용;박양원
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.61-70
    • /
    • 2002
  • 환경친화적이면서 저가의 비이온성 계면활성제가 함유된 소화약제를 조제하고 이의 물성과 소화약제 성능시험을 수행하였다. 약제의 주된 계면활성제로서 에톡실레이티이드 솔비톨 셉타올레이트, 에톡실레이트 솔비톨 트리올레이트 그리고 선형 에톡실레이트 이차 알코올을 사용하였다. 본 연구에서는 휘발유의 부피보다 4배 가량의 6% 소화약제가 투입되는 경우 화재를 진압할 수 있는 능력을 가지고 있는 것을 알 수 있었다. 1단위 B급 화재 진화 시험을 수행한 결과, 소화성능은 계면활성제의 농도에 정비례하는 것으로 나타났다.

분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire)

  • 김호영;오상엽;정진택
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire)

  • 오상엽;김호영;정진택
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

고지방식이로 비만을 유발한 마우스의 알레르기 비염에 대한 방풍통성산(防風通聖散)의 효과 (The Effect of Bangpungtongsungsan on Allergic Rhinitis Of Obese Mouse Fed High Fat Diet.)

  • 김동현;홍승욱
    • 한방안이비인후피부과학회지
    • /
    • 제29권1호
    • /
    • pp.1-15
    • /
    • 2016
  • Objective : For various reasons, Obesity & Rhinitis are constantly rising. So Interest of treatment has been expanding. We want to verify The Chungyeol (fire extinguishing) Lisup (Draining) effect of Bangpungtongsungsan on obese model of allergy rhinitis.Material and Methods : BALB/c mouse were divided four groups: control(CON), allergic induction(ARE), Bangpungtongsungsan extract administration(BTT), Bangpungtongsungsan double concentration extract administration (BT2T). Every group except control group were caused allergic rhinitis by Ovalbumin. BTT & BT2T were orally administered the Bangpungtongsungsan for 21days. Since then we observed the liver tissue cell and the nasal mucous membrane.Results : In comparison with ARE, experimental groups show relief of the nasal mucous membrane damage(secretion of mucus decrease, Itching decrease), Th2 eruption control(IL-4 decline), effect of anti-inflamatory(reducing TNF-α creation, decreasing of iNOS through NF-κB activation-inhibition). In addition, experimental groups show a loss in weight, diminished accumulation of fat. (decreasing within liver tissue, reducing TNF-α creation) BT2T is more effective to BTT.Conclusion : Bangpungtongsungsan treat obese model on allergy rhinitis thereby control fat augmentation, relieving inflammation.

기능성 경사 재료의 적용을 통한 진공 인터럽터의 삼중점 전계 완화 (Reduction of the Electric Field Concentration at the Triple Junction of the Vacuum Interrupter by Using the Application of Functionally Graded Material)

  • 최승길;구치욱;주흥진
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.630-635
    • /
    • 2015
  • A vacuum Interrupter (VI), a core part that composes the breaking part of medium-voltage vacuum circuit breaker (VCB), has the excellent insulation performance and arc-extinguishing capability. $SF_6$ gas had been used for the external insulation of VIs since the dielectric strength of $SF_6$ gas is superior to that of other insulation gases. However, because of environmental problems related with global warming, a solid-insulated technology was recently researched. The functionally graded material (FGM), as changing spatially the distribution of the relative permittivity inside an insulator, can reduce the electric field stress at the specific region. Especially, the external insulation performance of the VI with the molded FGM insulator is greatly improved as compared with that of the existing VI or the VI with a new external shield. In this paper, the effectiveness of this FGM insulator is verified by the numerical simulation.