• 제목/요약/키워드: Extinguishing Test

검색결과 104건 처리시간 0.024초

미분무수 소화설비의 선박용 기관실 적용에 관한 연구 (A Study on the Application of Water Mist Fire Extinguishing System to Machinery Spaces)

  • 김기옥;안병호;양우진;김영한
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.132-133
    • /
    • 2005
  • A study to evaluate the fire extinguishing performance of the water mist system inside simulated machinery spaces according to IMO MSC/Circ.668 was performed. Fire tests were conducted inside a compartment having a area 100$m^2$(10m${\times}$10m) with a ceiling height of 10m and door opening of 2m${\times}$2m in size. Test fuels were used heptane, diesel, wood crib and mineral oil. Water mist nozzles were installed downward at ceiling and horizontally at bilge area. All fires in the test were extinguished within 15minutes of system activation and there was no reignition or fire spread.

  • PDF

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

성능위주 소화설비 적용을 위한 표준랙크의 화재확산속도 평가 (Evaluation on Fire Spread Speed of Standard Rack in Korea for Performance based Fire Extinguishing System)

  • 조규환;여인환
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.84-91
    • /
    • 2016
  • 물품이 수직 집약적인 형태로 적재되는 랙크식 창고는 화재발생 시 화염의 급속한 상승으로 인해 그 피해가 매우 심각하다. 이에 ESFR 및 In-Rack 스프링클러, 수직 및 수평차단막 등, 다양한 소화설비 적용을 통해 화재확산 억제에 노력하고 있으나 랙크의 크기 및 적재밀도, 적재물품의 종류 등, 매우 다양한 구성조건으로 인해 적절한 소화설비 선정에 어려움이 있다. 이에 본 연구에서는 현장조사 및 설문조사 등을 통해 국내 랙크식 창고 실정을 반영한 표준랙크를 제작하였으며, 발화위치 조건에 따른 화재특성 확인을 위해 실규모화재시험을 수행하였다. 이를 통해 도출된 화재확산속도는 향후, 개발 및 적용 예정 소화설비들의 성능비교를 위한 기초자료로서 유용하게 활용될 것으로 기대한다.

스프링클러 소화설비의 목조문화재 소화성능에 관한 연구 (The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties)

  • 노삼규;함은구;김동철
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.51-57
    • /
    • 2011
  • 본 연구는 국내 목조문화재의 화재에 대한 수계 자동소화시스템 중에 범용의 스프링클러 소화시스템에 대한 소화성능을 소화실험을 통하여 확인해 보았다. 목조문화재는 가연성의 재질로 구성되어 있어 화재에 취약하며, 방화의 경우 화재의 성상 초기부터 화원의 규모가 커질 수 있다. 본 실험에 적용된 스프링클러 헤드는 방사압 1 bar, 방수량 80 lpm의 사양을 지니고 있다. 소화실험의 유형은 화원의 규모별, 문화재 규모별로 각각 둘로 구분하여 소화성능을 실험하였다. 소화실험을 통해 확인된 사항은 천장이 높으면 소화 시간이 지연되는 결과가 발생하며, 화원의 규모가 2단위에서는 소화는 가능하였지만 소화가 지연되는 것으로 나타났다. 그 결과 천장이 높고, 화원의 규모가 2단위 이상이 되면 소화성능이 낮을 것으로 예측된다. 실제 목조문화재의 화재 성장 환경이 소화실험 모형보다 유리하다는 측면을 고려해야 한다. 그러므로 스프링클러 소화설비를 목조문화재에 적용 할 때에 헤드간 거리 헤드의 선정 등 충분한 검증이 요구된다.

A STUDY ON THE RISK PROTECTION OF THE MOLD TRANSFORMER

  • Chung, Young-Ki;Jung, Jong-Wook;Kim, Jae-Chul;Kwak, Hee-Ro;Lee, Su-Kyung
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.219-226
    • /
    • 1997
  • This paper investigates and analyzes the installation and failure status of mold transformer being used in domestic subways and describes the extinguishing process by time through the combustion test of winding part of mold transformer. Condition of installed mold transformers and classes of fire were surveyed and the mold transformer was burned in a horizontal heating furnace. It was confirmed that the mold transformer is self extinguishing and nonflammability. According to this results, the suitable standard of fire protection for the mold transformer was demanded after review of domestic and abroad law. It is expected that the cost of fire protection equipment can be reduced by using the status and combustion test result of mold transformer.

  • PDF

압력스위치 성능시험보고 (A Report on Test Results of Pressure Operated Switch)

  • 권오승
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

가스계 소화약제의 소화성능 평가에 관한 연구 (A Study on Fire Extinguishing Ability Evaluation of Gaseous Extinguishing Agents)

  • 임우섭;정종진;남동군;최근주;김종원
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.483-486
    • /
    • 2009
  • 국제사회의 할론계 소화약제 사용규제가 본격화 되면서 차세대 소화약제에 대한 개발은 시급한 사안으로 다가왔다. 그중에서도 청정소화약제에 해당하는 가스계 소화약제의 개발은 상당히 진척되었으며, 가스계 소화약제의 소화성능에 관한 평가는 화재발생시 인명과 재산상의 손실을 최소화하기 위한 중요한 평가요소이다. 본 연구는 기존의 이산화탄소 소화약제와 새로운 형태의 소화약제인 Novec의 소화성능을 비교 평가하기 위해서 Cup Burner Test를 이용하여 실험을 행하였으며, 에탄올, 노르말헵탄, 톨루엔과 가솔린을 원료하여 실험한 결과 Nocvec의 소화성능이 이산화탄소 소화약제보다 우수한 것으로 나타났다.

  • PDF

자동차 폐유리 분말을 이용한 팽창유리 소화약제의 제조 (Manufacturing of Extinguishing Powder of Expanded Glass from Recycling Automotive Glass Powder)

  • 전덕우;박정호;이용권
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.547-552
    • /
    • 2022
  • 본 연구에서 폐차 처리되는 자동차 유리 중 일반 강화유리 즉 윈도우 유리를 사용하여 균일한 품질의 팽창유리 제조 기술을 확보하고, 제조된 팽창유리가 리튬배터리 화재 진압용으로서 활용이 가능한지 검증하였다. 폐유리를 활용하여 팽창유리룰 제조하는 공정은 크게 폐유리 파쇄(Crushing) → 분쇄 (Milling)→ 구상화(Granulation) → 발포(Expansion) → 냉각(Cooling)으로 구분하며, 최종으로 팽창유리의 입자크기 1~4 ø mm가 80 % 이상의 수율이 나오는 최적 조건을 얻기 위해 실험을 수차례 수행하였다. 폐유리와 발포제의 배합량과 공정 조건에 따라 기공의 형태, 겉보기 비중, 표면적, 흡수율, 흡착율, 기공율 및 안전성 등을 분석하였다. 기공의 형태는 SEM 표면 분석을 통해 이루어 졌으며, 겉보기 비중, 흡수율, 흡착율 및 기공율은 표준 시험법에 따라 하였고 안전성은 8대 중금속 분석과 X-ray 회절 분석을 통해 결정화가 있는지 여부를 확인하였다. 표면분석과 물성치를 비교하여 배터리용 소화약제로서 더 적합한 sample을 선정하여, 고부가가치의 활용이 가능한 리튬 배터리 화재의 적응성 시험결과 만족한 것으로 확인되었다.

최초의 평가시험 방법을 고려한 수격흡수기의 장치에 관한 연구 (A Study on the Water Hammer Arrester Considering the Way of First Assessment Test)

  • 염문천;한용택
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.53-59
    • /
    • 2015
  • 배관시스템의 불안정한 유동에 의해 생성되는 수격현상은 관내 압력의 과도한 변화, 진동 및 소음을 일으킬 수 있다. 이러한 수격현상은 관로, 펌프 및 밸브등의 시설물에 기계적인 사고를 유발시키는 원인이 되기도 한다. 한편, 국내에서는 수격현상으로 인한 피해를 최소화하기 위하여 수격흡수기를 제조 및 사용하여 왔으며, 그동안 별도의 기준이 없어 저가 위주로 생산 및 설치되어 왔다. 따라서, 본 연구에서는 수격흡수기 성능에 대한 최소 가이드라인을 제시하기 위하여, 하나의 배관으로 검증 가능한 시험방법, 수계소화설비에서 수격발생을 가정한 시험방법, 개방충격압과 차단충격압으로 구분한 흡수시험 방법, 배관을 분기한 시험시설 구성 방법 등의 다양한 방법들을 통하여 수격흡수기의 성능을 기준화 할 수 있는 방법등에 대하여 고안하였다. 그리고, 최종적으로는 U자형 배관과 시험용 추를 이용한 간단한 기계적 방식으로 수격흡수기의 수격압 흡수성능을 검증할 수 있는 실험 장치를 최초로 고안하여, 소방용 수격흡수기의 인정기준이 제정되었다.